Arieh Levy Pinto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arieh Levy Pinto has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Morgan
National Heart and Lung Institute, Imperial College London, London, United Kingdom
1 shared publication - Bogachan Tahirbegi
Department of Biochemistry, School of Biological and Behavioural Sciences, Queen Mary University of London, London, UK
1 shared publication - Christopher Abbott Reece Chapman
School of Engineering and Materials Science, Queen Mary University of London 1 , London
1 shared publication - Collin Mattathil
Department of Bioengineering, Imperial College London , London SW7 2BP, United Kingdom
1 shared publication - Estelle Cuttaz
Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
1 shared publication - Fotios Spyridakos
Department of Bioengineering, Imperial College London , London SW7 2BP, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 1 September 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (3) , 036115
Surface electromyography using dry polymeric electrodes
Conventional wet Ag/AgCl electrodes are widely used in electrocardiography, electromyography (EMG), and electroencephalography (EEG) and are considered the gold standard for biopotential measurements. However, these electrodes require substantial skin preparation, are single use, and cannot be used for continuous monitoring (>24 h). For these reasons, dry electrodes are preferable during surface electromyography (sEMG) due to their convenience, durability, and longevity. Dry conductive elastomers (CEs) combine conductivity, flexibility, and stretchability. In this study, CEs combining poly(3,4-ehtylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) in polyurethane are explored as dry, skin contacting EMG electrodes. This study compares these CE electrodes to commercial wet Ag/AgCl electrodes in five subjects, classifying four movements: open hand, fist, wrist extension, and wrist flexion. Classification accuracy is tested using a backpropagation artificial neural network. The control Ag/AgCl electrodes have a 98.7% classification accuracy, while the dry conductive elastomer electrodes have a classification accuracy of 99.5%. As a conclusion, PEDOT based dry CEs were shown to successfully function as on-skin electrodes for EMG recording, matching the performance of Ag/AgCl electrodes, while addressing the need for minimal skin prep, no gel, and wearable technology.
- 1 September 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (3) , 036115
Open AccessSurface electromyography using dry polymeric electrodes
Conventional wet Ag/AgCl electrodes are widely used in electrocardiography, electromyography (EMG), and electroencephalography (EEG) and are considered the gold standard for biopotential measurements. However, these electrodes require substantial skin preparation, are single use, and cannot be used for continuous monitoring (>24 h). For these reasons, dry electrodes are preferable during surface electromyography (sEMG) due to their convenience, durability, and longevity. Dry conductive elastomers (CEs) combine conductivity, flexibility, and stretchability. In this study, CEs combining poly(3,4-ehtylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) in polyurethane are explored as dry, skin contacting EMG electrodes. This study compares these CE electrodes to commercial wet Ag/AgCl electrodes in five subjects, classifying four movements: open hand, fist, wrist extension, and wrist flexion. Classification accuracy is tested using a backpropagation artificial neural network. The control Ag/AgCl electrodes have a 98.7% classification accuracy, while the dry conductive elastomer electrodes have a classification accuracy of 99.5%. As a conclusion, PEDOT based dry CEs were shown to successfully function as on-skin electrodes for EMG recording, matching the performance of Ag/AgCl electrodes, while addressing the need for minimal skin prep, no gel, and wearable technology.