Chunyan Zang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chunyan Zang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Feng Jiang
School of Electrical and Electronics Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications - Peng Li
China Electric Power Research Institute, State Grid Corporation of China, Beijing 100192, China
2 shared publications - Ruijuan Tan
China Electric Power Research Institute, State Grid Corporation of China, Beijing 100192, China
2 shared publications - Chengyan Liu
Henan University
1 shared publication - Chuanhui Xu
Guangxi University
1 shared publication - Dandan Zhang
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication
Latest Publications
- Open Access
Nonlinear Fatigue Damage Assessment for Transformer Windings Under Thermal Aging and Repeated Short-Circuit Loading
Transformer winding failures are driven by the cumulative degradation from repeated short-circuit shocks rather than a single extreme event. Current standards rely on static strength checks using as-manufactured material properties, ignoring both thermal aging and load-history effects. To address this gap, we propose a nonlinear fatigue cumulative damage framework that couples a long-term thermal-aging spectrum, converted into an equivalent aging duration and a global property correction, with a micro-spectrum of individual short-circuit events, discretized into an eight-level variable-amplitude stress history. The resulting six-step workflow shifts the paradigm from passive strength checking to proactive life management, offering utilities a physics-informed framework for estimating the residual fatigue life of aging transformers.
Open AccessNonlinear Fatigue Damage Assessment for Transformer Windings Under Thermal Aging and Repeated Short-Circuit Loading
Transformer winding failures are driven by the cumulative degradation from repeated short-circuit shocks rather than a single extreme event. Current standards rely on static strength checks using as-manufactured material properties, ignoring both thermal aging and load-history effects. To address this gap, we propose a nonlinear fatigue cumulative damage framework that couples a long-term thermal-aging spectrum, converted into an equivalent aging duration and a global property correction, with a micro-spectrum of individual short-circuit events, discretized into an eight-level variable-amplitude stress history. The resulting six-step workflow shifts the paradigm from passive strength checking to proactive life management, offering utilities a physics-informed framework for estimating the residual fatigue life of aging transformers.
- Open Access
Study on Cumulative Effects of Mechanical Forces and Deformation in Power Transformer Windings
Winding damage is one of the most common and highly destructive faults in power transformers. To analyze the winding force and deformation under short-circuit conditions, this paper establishes a three-dimensional simulation model of a 220 kV oil-immersed power transformer. The force distribution of the windings under different short-circuit scenarios is investigated, and the vulnerable locations in different simulation model configurations are identified. The effects of variations in spacer blocks and tie bar quantities, as well as differences in material parameters of each component, on the evolution of weak-force regions are summarized. Finally, the influence of short-circuit cumulative effects on the maximum winding deformation is studied, providing a theoretical basis for transformer condition-based maintenance and fault prediction.
Open AccessStudy on Cumulative Effects of Mechanical Forces and Deformation in Power Transformer Windings
Winding damage is one of the most common and highly destructive faults in power transformers. To analyze the winding force and deformation under short-circuit conditions, this paper establishes a three-dimensional simulation model of a 220 kV oil-immersed power transformer. The force distribution of the windings under different short-circuit scenarios is investigated, and the vulnerable locations in different simulation model configurations are identified. The effects of variations in spacer blocks and tie bar quantities, as well as differences in material parameters of each component, on the evolution of weak-force regions are summarized. Finally, the influence of short-circuit cumulative effects on the maximum winding deformation is studied, providing a theoretical basis for transformer condition-based maintenance and fault prediction.
- 11 March 2024
- Published by Springer Nature
- p. 225-237
Research on Acoustic-Vibration Joint Detection Fault Diagnosis of Abnormal Transformer
- 11 March 2024
- Published by Springer Nature
- p. 225-237
Research on Acoustic-Vibration Joint Detection Fault Diagnosis of Abnormal Transformer
- 7 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1827-1835
A Modified Vector Jiles-Atherton Hysteresis Model for the Design of Hysteresis Devices
In this paper, a modified vector Jiles-Atherton (JA) model is proposed to simulate permanent magnet materials. Two correction coefficients related to the maximum magnetic flux density are introduced to improve the accuracy of the vector JA model in the simulation of the minor hysteresis loops. Hook-Jeeves direct search algorithm is used to identify the correction coefficients in the modified vector JA model. The hysteresis curves of an isotropic FeCrCo are measured, which show that the simulation accuracy of the modified approach is greatly improved. A single-side axial permanent magnet hysteresis damper is modeled by the finite element method (FEM) and is designed to verify the reliability of the modified model. The results of the experiment and simulation agree well, which means that the modified vector JA model has better accuracy than the basic approach in the analysis and design of hysteresis devices.
- 7 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1827-1835
A Modified Vector Jiles-Atherton Hysteresis Model for the Design of Hysteresis Devices
In this paper, a modified vector Jiles-Atherton (JA) model is proposed to simulate permanent magnet materials. Two correction coefficients related to the maximum magnetic flux density are introduced to improve the accuracy of the vector JA model in the simulation of the minor hysteresis loops. Hook-Jeeves direct search algorithm is used to identify the correction coefficients in the modified vector JA model. The hysteresis curves of an isotropic FeCrCo are measured, which show that the simulation accuracy of the modified approach is greatly improved. A single-side axial permanent magnet hysteresis damper is modeled by the finite element method (FEM) and is designed to verify the reliability of the modified model. The results of the experiment and simulation agree well, which means that the modified vector JA model has better accuracy than the basic approach in the analysis and design of hysteresis devices.
- Open Access
Improved Insulation Properties of Polypropylenes in HVDC Cables Using Aqueous Suspension Grafting
Owing to its lack of crosslinking, polypropylene (PP) is considered an environmentally friendly alternative to crosslinked polyethylene as high-voltage direct current (HVDC) cable insulation. However, pure PP can accumulate space charges under a HVDC, and thus must be modified for use as an insulating material for HVDC cables. In this study, 4-methylstyrene is grafted onto PP using an aqueous suspension grafting method to improve its properties. The effects of the swelling time, reaction time, and 4-methylphenylene concentration on the reaction were investigated. The optimum process conditions were determined, including an optimum grafting ratio of 0.97%. The volume resistivity, ability to suppress space-charge accumulation, and DC breakdown strength of modified PP were also studied. Modified PP with a grafting ratio of 0.88% showed optimal space-charge suppression and the highest volume resistivity and breakdown strength. The work will facilitate the design and development of more efficient insulation materials for HVDC cables.
Open AccessImproved Insulation Properties of Polypropylenes in HVDC Cables Using Aqueous Suspension Grafting
Owing to its lack of crosslinking, polypropylene (PP) is considered an environmentally friendly alternative to crosslinked polyethylene as high-voltage direct current (HVDC) cable insulation. However, pure PP can accumulate space charges under a HVDC, and thus must be modified for use as an insulating material for HVDC cables. In this study, 4-methylstyrene is grafted onto PP using an aqueous suspension grafting method to improve its properties. The effects of the swelling time, reaction time, and 4-methylphenylene concentration on the reaction were investigated. The optimum process conditions were determined, including an optimum grafting ratio of 0.97%. The volume resistivity, ability to suppress space-charge accumulation, and DC breakdown strength of modified PP were also studied. Modified PP with a grafting ratio of 0.88% showed optimal space-charge suppression and the highest volume resistivity and breakdown strength. The work will facilitate the design and development of more efficient insulation materials for HVDC cables.
- Open Access
A Dual-Mode Hybrid Step-Up Converter with Stable Output for Vibration Energy Harvesting
A dual-mode hybrid step-up circuit for electromagnetic energy harvesting (EVEH) is proposed in this paper, with the merits of continuous output power delivery with and without external vibrations, simple architecture, and no need for extra circuits to start up. The proposed hybrid converter combines a multi-stage voltage multiplier (VM) with a boost regulator, which utilizes the winding inductance of the electromagnetic energy harvester as a boost inductor. With external vibration, the proposed circuit powers the load and stores energy in the super-capacitor through VM mode. When external vibration disappears, it automatically switches to boost mode and powers the load using the energy stored in the supercapacitor. For hybrid mode operation, the number of VM stages is optimized considering the following three aspects: sufficient voltage gains when vibration is on, time durations to provide constant power when vibration is off for as long as possible, and low losses at VM stage. A GaN-based dual-mode hybrid converter is built to verify the output regulation capability with an in-house-designed electromagnetic energy harvester. The outputs of the hybrid circuit achieve 4.05 V and 1.64 mW at a 100-Hz external vibration frequency and an acceleration of 0.7 g. The peak efficiency of the proposed hybrid converter reaches 60.7%. When external vibration disappears, the circuit is able to maintain a stable output for 13 s with a super-capacitor of 0.1 F.
Open AccessA Dual-Mode Hybrid Step-Up Converter with Stable Output for Vibration Energy Harvesting
A dual-mode hybrid step-up circuit for electromagnetic energy harvesting (EVEH) is proposed in this paper, with the merits of continuous output power delivery with and without external vibrations, simple architecture, and no need for extra circuits to start up. The proposed hybrid converter combines a multi-stage voltage multiplier (VM) with a boost regulator, which utilizes the winding inductance of the electromagnetic energy harvester as a boost inductor. With external vibration, the proposed circuit powers the load and stores energy in the super-capacitor through VM mode. When external vibration disappears, it automatically switches to boost mode and powers the load using the energy stored in the supercapacitor. For hybrid mode operation, the number of VM stages is optimized considering the following three aspects: sufficient voltage gains when vibration is on, time durations to provide constant power when vibration is off for as long as possible, and low losses at VM stage. A GaN-based dual-mode hybrid converter is built to verify the output regulation capability with an in-house-designed electromagnetic energy harvester. The outputs of the hybrid circuit achieve 4.05 V and 1.64 mW at a 100-Hz external vibration frequency and an acceleration of 0.7 g. The peak efficiency of the proposed hybrid converter reaches 60.7%. When external vibration disappears, the circuit is able to maintain a stable output for 13 s with a super-capacitor of 0.1 F.
- Open Access
- 1 April 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (4) , 610-617
Advanced compensation mode for cascade multilevel static synchronous compensator under unbalanced voltage
An improved control scheme for delta‐connected cascade multilevel static synchronous compensator (STATCOM) operating under unbalanced conditions is proposed. The individual phase instantaneous current control is suitable for delta‐connected cascade multilevel STATCOM which can be equivalent to three single‐phase inverters. To compensate the system imbalance, the reactive control mode and the voltage control mode are studied, and the discrete current loop controller has been designed. Accordingly, the cascade multilevel STATCOM can maintain normal operation under unbalanced voltage by using the individual phase instantaneous current control strategy while the unbalanced system can be effectively compensated by the two modified compensation modes. The proposed control scheme has been verified by simulation and experimental results based on a three‐phase 36‐chain cascade multilevel STATCOM laboratory prototype are shown.
- 1 April 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (4) , 610-617
Open AccessAdvanced compensation mode for cascade multilevel static synchronous compensator under unbalanced voltage
An improved control scheme for delta‐connected cascade multilevel static synchronous compensator (STATCOM) operating under unbalanced conditions is proposed. The individual phase instantaneous current control is suitable for delta‐connected cascade multilevel STATCOM which can be equivalent to three single‐phase inverters. To compensate the system imbalance, the reactive control mode and the voltage control mode are studied, and the discrete current loop controller has been designed. Accordingly, the cascade multilevel STATCOM can maintain normal operation under unbalanced voltage by using the individual phase instantaneous current control strategy while the unbalanced system can be effectively compensated by the two modified compensation modes. The proposed control scheme has been verified by simulation and experimental results based on a three‐phase 36‐chain cascade multilevel STATCOM laboratory prototype are shown.
- 1 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00849162,p. 580-583
Investigation on change laws of arc burning time of the arc plasma
Arc burning time is the time interval from arc burning until arc quenching, which is one of the main symbol parameters of the arc plasma characteristic. As the length of arc burning time can do great influence on the arc energy and the two-phase change process of the break arc directly, it is significant for us to do some researches on its influence factors and change laws. To take the DC break arc between the low power relay contacts for an example, the paper studied the arc burning processes of two typical arc plasma - high purity nitrogen arc and air arc. When the relay contacts break resistant or inductive loads, it gained the relationships between the arc burning time with different atmospheres and load characters, as well as the change laws of arc burning time with the change of arc current and voltage. It also gives some deep analysis and discussions on the experimental results, which combined with the physical mechanism of two-phase change process of the break arc. Finally the paper built a basic mathematics model of arc burning time on the typical arc plasma, which can be helpful for the researchers to know more information about the arc burning process.
- 1 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00849162,p. 580-583
Investigation on change laws of arc burning time of the arc plasma
Arc burning time is the time interval from arc burning until arc quenching, which is one of the main symbol parameters of the arc plasma characteristic. As the length of arc burning time can do great influence on the arc energy and the two-phase change process of the break arc directly, it is significant for us to do some researches on its influence factors and change laws. To take the DC break arc between the low power relay contacts for an example, the paper studied the arc burning processes of two typical arc plasma - high purity nitrogen arc and air arc. When the relay contacts break resistant or inductive loads, it gained the relationships between the arc burning time with different atmospheres and load characters, as well as the change laws of arc burning time with the change of arc current and voltage. It also gives some deep analysis and discussions on the experimental results, which combined with the physical mechanism of two-phase change process of the break arc. Finally the paper built a basic mathematics model of arc burning time on the typical arc plasma, which can be helpful for the researchers to know more information about the arc burning process.