Lara Góis Floresta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lara Góis Floresta has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Lucas Alves da Mota Santana
Federal University of Sergipe, Graduate Program in Dentistry, R. Cláudio Batista, Aracaju, 49060-108 Sergipe, SE, Brazil
9 shared publications - Wilton Mitsunari Takeshita
Department of Diagnosis and Surgery, School of Dentistry São Paulo State University (UNESP) Araçatuba SP Brazil
4 shared publications Cleverson Luciano Trento
School of Dentistry Federal University of Sergipe (UFS) Aracaju SE Brazil
3 shared publications- Cleverson Luciano Trento
Universidade Federal de Sergipe, Brasil
3 shared publications Lysandro Pinto Borges
School of Pharmacy Federal University of Sergipe (UFS) Aracaju SE Brazil
3 shared publications- Breno Ferreira Barbosa
Universidade Federal de Sergipe, Brasil
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Revista da Sociedade Brasileira de Medicina Tropical
- Vol. 59, e05832025
Alert on a Novel South American Bat Coronavirus with a Furin-Cleavage Site: A One Health Early Warning
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Revista da Sociedade Brasileira de Medicina Tropical
- Vol. 59, e05832025
Open AccessAlert on a Novel South American Bat Coronavirus with a Furin-Cleavage Site: A One Health Early Warning
- 18 October 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (3) , 1812-1819
The Application of ImageJ Software for Roughness Analysis of Dental Implants
ImageJ software is a versatile, open-source software for visualizing, processing, and analyzing images, which has contributed to its widespread adoption in the scientific community. A notable application of this software is its integration with scanning electron microscope images, where surface roughness can be quantified. This study aims to highlight the need for knowledge and standardization of the technique selected for analysis to ensure the viability of ImageJ software as a reliable alternative for evaluating the surface roughness of dental implants. Images obtained by scanning electron microscopy, depending on the plugin used or the researcher’s standardization, yielded different surface roughness values, which were assessed via ImageJ. Thirty grade 4 titanium osseointegrated dental implants via all treated with similar surface treatment methods were studied. Two groups were formed for analysis via ImageJ: Group 1 assessed surface roughness using only the SurfCharJ plugin (n = 12), and Group 2 assessed surface roughness using both the roughness/waviness and SurfCharJ plugin (n = 18). The results showed that the use of different plugins can lead to different outcomes, potentially affecting the quality of the study. This study concluded that a standardized methodology is necessary to ensure consistency in results obtained via ImageJ.
- 18 October 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (3) , 1812-1819
The Application of ImageJ Software for Roughness Analysis of Dental Implants
ImageJ software is a versatile, open-source software for visualizing, processing, and analyzing images, which has contributed to its widespread adoption in the scientific community. A notable application of this software is its integration with scanning electron microscope images, where surface roughness can be quantified. This study aims to highlight the need for knowledge and standardization of the technique selected for analysis to ensure the viability of ImageJ software as a reliable alternative for evaluating the surface roughness of dental implants. Images obtained by scanning electron microscopy, depending on the plugin used or the researcher’s standardization, yielded different surface roughness values, which were assessed via ImageJ. Thirty grade 4 titanium osseointegrated dental implants via all treated with similar surface treatment methods were studied. Two groups were formed for analysis via ImageJ: Group 1 assessed surface roughness using only the SurfCharJ plugin (n = 12), and Group 2 assessed surface roughness using both the roughness/waviness and SurfCharJ plugin (n = 18). The results showed that the use of different plugins can lead to different outcomes, potentially affecting the quality of the study. This study concluded that a standardized methodology is necessary to ensure consistency in results obtained via ImageJ.
- 27 May 2024
- Published by Wiley in Oral Surgery
- Vol. 17 (4) , 401-404
BRAF V600E mutation in ameloblastomas: Where are we?
- 27 May 2024
- Published by Wiley in Oral Surgery
- Vol. 17 (4) , 401-404
BRAF V600E mutation in ameloblastomas: Where are we?
- 8 April 2024
- Published by Wiley in Oral Surgery
- Vol. 17 (4) , 394-396
Exacerbation of pleomorphic adenoma in the upper lip after a traumatic event: An uncommon presentation
- 8 April 2024
- Published by Wiley in Oral Surgery
- Vol. 17 (4) , 394-396
Exacerbation of pleomorphic adenoma in the upper lip after a traumatic event: An uncommon presentation
- 5 February 2024
- Published by Wiley in Oral Surgery
- Vol. 17 (3) , 299-301
Exacerbation of oral pemphigus vulgaris after COVID‐19 vaccine: Coincidence or potential adverse effect?
- 5 February 2024
- Published by Wiley in Oral Surgery
- Vol. 17 (3) , 299-301
Exacerbation of oral pemphigus vulgaris after COVID‐19 vaccine: Coincidence or potential adverse effect?
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 53, e20240024
Comparative analysis of microgaps in angled and straight components: a laboratory study
Introduction The dental implant rehabilitation protocol is a well-established treatment option for edentulous patients with a high success rate. However, there are factors that can lead to difficulty in continuation and even complete loss of rehabilitation. Microgaps are spaces found between the implant and prosthetic abutment that are caused by the limit of precision in the manufacturing of the implant. This space can cause micromovements and bacterial microleakage that can compromise the long-term useful life of the implant. Objective Measure and evaluate microgaps in angled and straight implants using scanning electron microscopy. To carry out the study, a total of 30 SIN® osseointegrated implants were used, 15 of which were straight and 15 angled. Material and method For the comparative analysis of these components, scanning electron microscopy was used, carried out by a properly calibrated and experienced researcher. Result It was observed that the microgap measurements of both components are in accordance with the clinically acceptable values presented in the literature, however the microgap values of the angled components were considerably higher compared to the straight components. Conclusion Although the values presented corroborate the data presented in the literature, additional studies are necessary for a more comprehensive and in-depth understanding of the relationship between the microgaps of the morse cone system components.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 53, e20240024
Open AccessComparative analysis of microgaps in angled and straight components: a laboratory study
Introduction The dental implant rehabilitation protocol is a well-established treatment option for edentulous patients with a high success rate. However, there are factors that can lead to difficulty in continuation and even complete loss of rehabilitation. Microgaps are spaces found between the implant and prosthetic abutment that are caused by the limit of precision in the manufacturing of the implant. This space can cause micromovements and bacterial microleakage that can compromise the long-term useful life of the implant. Objective Measure and evaluate microgaps in angled and straight implants using scanning electron microscopy. To carry out the study, a total of 30 SIN® osseointegrated implants were used, 15 of which were straight and 15 angled. Material and method For the comparative analysis of these components, scanning electron microscopy was used, carried out by a properly calibrated and experienced researcher. Result It was observed that the microgap measurements of both components are in accordance with the clinically acceptable values presented in the literature, however the microgap values of the angled components were considerably higher compared to the straight components. Conclusion Although the values presented corroborate the data presented in the literature, additional studies are necessary for a more comprehensive and in-depth understanding of the relationship between the microgaps of the morse cone system components.
- 20 November 2023
- Published by Wiley in Oral Surgery
- Vol. 17 (2) , 192-193
ChatGPT‐4 as auxiliary tool in the temporomandibular disorders diagnostic: An opinion
- 20 November 2023
- Published by Wiley in Oral Surgery
- Vol. 17 (2) , 192-193
ChatGPT‐4 as auxiliary tool in the temporomandibular disorders diagnostic: An opinion
- 7 September 2023
- Published by Wiley in Oral Surgery
- Vol. 17 (2) , 181-184
Chronic suppurative osteomyelitis secondary to endodontic treatment and posterior extraction of mandibular third molars: An uncommon case
- 7 September 2023
- Published by Wiley in Oral Surgery
- Vol. 17 (2) , 181-184
Chronic suppurative osteomyelitis secondary to endodontic treatment and posterior extraction of mandibular third molars: An uncommon case
- Open Access
- 1 August 2023
- Published by Forschungsgesellschaft für Arbeitsphysiologie und Arbeitsschutz e.V. in EXCLI Journal
- Vol. 22, 749-751
Can GPT-4 be a viable alternative for discussing complex cases in digital oral radiology?
- 1 August 2023
- Published by Forschungsgesellschaft für Arbeitsphysiologie und Arbeitsschutz e.V. in EXCLI Journal
- Vol. 22, 749-751
Open AccessCan GPT-4 be a viable alternative for discussing complex cases in digital oral radiology?