MSMosope T. Soda

Mosope T. Soda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mosope T. Soda has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Three-Dimensional Printed Anterior Cervical Standalone Combined Cage-Plate—300 Consecutive Medical Implants

    by Mosope Soda, Bradley Moatz, Paul Asdourian, Daina Brooks, Bryan Cunningham, Paul C. McAfee

    Objective: The primary objective was to investigate the perioperative parameters and clinical outcomes of a novel three-dimensional (3D) printed titanium interbody spacer and integral screws. The secondary objective was to compare the survivorship rate of the 3D-printed titanium integrated spacer (3D-printed spacer group) with that of a polyether-ether-ketone (PEEK) integrated spacer (PEEK group) and traditional allograft spacer combined with an anterior cervical plate (control group). Study Design: This is a retrospective study comprising 157 consecutive patients (representing 300 surgical levels) investigating the perioperative and clinical outcomes of a novel 3D-printed titanium integrated spacer for anterior cervical diskectomy and fusion (ACDF). Methods: A consecutive series of 157 patients (N = 300 surgical levels) presenting with cervical radiculopathy, myelopathy, or spondylosis underwent ACDF with the 3D-printed titanium spacer. Perioperative outcomes including surgical time, estimated blood loss, length of hospital stay, and number of surgical levels were collected. Clinical outcomes including the American Spinal Injury Association neurologic impairment score and Neck Disability Index (NDI) were measured preoperatively and postoperatively. Survivorship was defined as no failures, no anterior revision surgeries, no instrumentation removals, and no subsidence requiring surgery. Results: The mean surgical time for the 3D-printed spacer group was 126.3 ± 34.0 minutes, the estimated blood loss was 85.9 ± 30.5 cc, and the length of hospital stay was 1.5 ± 1.4 days. Surgical levels were distributed as follows: 33.8% single-level, 42.7% two-level, 21.6% three-level, and 1.9% four-level ACDF procedures. 98.7% of patients in the 3D-printed spacer group reported improved American Spinal Injury Association scores. The mean NDI preoperatively was 37.2 ± 18.7, and the mean NDI postoperatively was 21.2 ± 18.3, with 58.6% of patients reporting NDI improvement of 15% or greater. Survivorship was observed in 97.4% of patients in the 3D-printed spacer group, 98.0% in the PEEK group, and 93.3% in the control group (chi-square analysis: X2 [1, N = 1529] = 16.9, P = 0.0002). Conclusion: A novel 3D-printed titanium spacer with integral screws for ACDF demonstrated improved survivorship rates compared with the traditional allograft spacer and anterior plate. Among 157 patients, only two required supplemental posterior fixation, one required removal for excessive kyphosis and were successfully revised with a 3D-printed corpectomy spacer, and one had notable subsidence at 6 weeks postoperatively (4 total failures based on the survivorship criteria; 97.4% survivorship success rate (153/157 patients)). Not a single case of neurologic progression was observed in the 3D-printed spacer group—no iatrogenic progressive radiculopathy nor myelopathy, unlike the control group.


  • 100 Complex posterior spinal fusion cases performed with robotic instrumentation

    by Brian McCormick, Paul L. Asdourian, Douglass C. Johnson, Bradley W. Moatz, Grant T. Duvall, Mosope T. Soda, Anna R. Beaufort, Liana G. Chotikul, Paul C. McAfee

    Robotic navigation has been shown to increase precision, accuracy, and safety during spinal reconstructive procedures. There is a paucity of literature describing the best techniques for robotic-assisted spine surgery for complex, multilevel cases or in cases of significant deformity correction. We present a case series of 100 consecutive multilevel posterior spinal fusion procedures performed for multilevel spinal disease and/or deformity correction. 100 consecutive posterior spinal fusions were performed for multilevel disease and/or deformity correction utilizing robotic-assisted placement of pedicle screws. The primary outcome was surgery-related failure, which was defined as hardware breakage or reoperation with removal of hardware. A total of 100 consecutive patients met inclusion criteria. Among cases included, 31 were revision surgeries with existing hardware in place. The mean number of levels fused was 5.6, the mean operative time was 303 min, and the mean estimated blood loss was 469 mL. 28 cases included robotic-assisted placement of S2 alar-iliac (S2AI) screws. In total, 1043 pedicle screws and 53 S2AI screws were placed with robotic-assistance. The failure rate using survivorship analysis was 18/1043 (1.7%) and the failure rate of S2AI screws using survivorship analysis was 3/53 (5.7%). Four patients developed postoperative wound infections requiring irrigation and debridement procedures. None of the 1043 pedicle screws nor the 53 S2AI screws required reoperation due to malpositioning or suboptimal placement. This case series of 100 multilevel posterior spinal fusion procedures demonstrates promising results with low failure rates. With 1043 pedicle screws and 53 S2AI screws, we report low failure rates of 1.7% and 5.7%, respectively with zero cases of screw malpositioning. Robotic screw placement allows for accurate screw placement with no increased rate of postoperative infection compared to historical controls. Level of evidence: IV, Retrospective review.