Qianfan Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qianfan Zhou has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Dai Wan
State Grid Hunan Electric Power Company Limited Research Institute, Changsha 410007, China
3 shared publications - Junhao Li
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications - Chunzhi Yang
College of Electrical and Information Engineering, Hunan University of Technology, Zhuzhou 412007, China
1 shared publication - Guidong He
College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
1 shared publication - Hengyi Zhou
State Grid Hunan Electric Power Company Limited Research Institute, Changsha 410007, China
1 shared publication - Jinbo Wu
State Grid Hunan Electric Power Company Limited Research Institute, Changsha 410007, China
1 shared publication
Latest Publications
- Open Access
- 9 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (22) , 4582
Two-Layer Cooperative Optimization of Flexible Interconnected Distribution Networks Considering Electric Vehicle User Satisfaction Degree
The scaled access of electric vehicles (EVs) exacerbates load fluctuations in distribution networks, which is not conducive to the stable and economic operation of the distribution networks. At present, user satisfaction degree is generally low. To avoid this problem, this paper proposed a two-layer cooperative optimization of flexible interconnected distribution networks considering EV user satisfaction degree. First, the EV user satisfaction degree model is established by considering EV users’ charging waiting time, charging power, and other indicators. At the same time, an EV charging mode switching model is constructed based on the number of EVs entering the network and their battery charge state. On this basis, the Monte Carlo algorithm is used to generate the results of the daily distribution of EV loads taking into account the user satisfaction degree, so as to improve the load ratio of the transformer in the distribution network. Further, a two-layer cooperative optimization of flexible interconnected distribution networks considering electric vehicle user satisfaction degree is developed with the daily operating cost of each network as the optimization objective. Finally, a flexible interconnected power distribution network consisting of three power distribution networks is used as an example for validation. The results show that this method is effective in improving EV user satisfaction degree and reducing the peak-to-valley ratio of the system load while taking into account the safe and economic operation of the distribution network, which greatly improves the reliability and economy of the operation of the flexible interconnected power distribution network.
- 9 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (22) , 4582
Open AccessTwo-Layer Cooperative Optimization of Flexible Interconnected Distribution Networks Considering Electric Vehicle User Satisfaction Degree
The scaled access of electric vehicles (EVs) exacerbates load fluctuations in distribution networks, which is not conducive to the stable and economic operation of the distribution networks. At present, user satisfaction degree is generally low. To avoid this problem, this paper proposed a two-layer cooperative optimization of flexible interconnected distribution networks considering EV user satisfaction degree. First, the EV user satisfaction degree model is established by considering EV users’ charging waiting time, charging power, and other indicators. At the same time, an EV charging mode switching model is constructed based on the number of EVs entering the network and their battery charge state. On this basis, the Monte Carlo algorithm is used to generate the results of the daily distribution of EV loads taking into account the user satisfaction degree, so as to improve the load ratio of the transformer in the distribution network. Further, a two-layer cooperative optimization of flexible interconnected distribution networks considering electric vehicle user satisfaction degree is developed with the daily operating cost of each network as the optimization objective. Finally, a flexible interconnected power distribution network consisting of three power distribution networks is used as an example for validation. The results show that this method is effective in improving EV user satisfaction degree and reducing the peak-to-valley ratio of the system load while taking into account the safe and economic operation of the distribution network, which greatly improves the reliability and economy of the operation of the flexible interconnected power distribution network.
- Open Access
- 21 September 2023
- Published by MDPI AG in Electronics
- Vol. 12 (18) , 3975
A High-Power Density DC Converter for Medium-Voltage DC Distribution Networks
A DC converter is the core equipment of voltage conversion and power distribution in a DC distribution network. Its operating characteristics have a profound impact on the flexible regulation of distributed resources in an active distribution network. It is challenging for the existing single-stage conversion topology to meet the requirements of distributed renewable energy connected to a multi-voltage level, medium-voltage grid. It is necessary to study the multistage transform power unit topology further, which can satisfy high reliability, high efficiency, and wide input range. This paper proposes a high-power density DC converter for medium-voltage DC networks with wide voltage levels. It adopts Buck-LLC integrated modular composition. The input ends of the high isolation resonant power unit are connected in series to provide high voltage endurance, and the output ends are connected in parallel to meet the high-power demand and achieve high-power transmission efficiency. The proposed series dual Buck-LLC resonant power unit topology can adjust the duty cycle of series dual buck circuits to meet the needs of different levels of medium-voltage DC power grids. The soft switching problem within the wide input range of all switching tubes is solved by introducing auxiliary inductors, thereby improving energy transmission efficiency. The auxiliary circuit and control parameters are optimized based on the research of each switching tube’s soft switching boundary conditions. Finally, an experimental prototype of a 6.25~7 kW power unit is designed and developed to prove the proposed topology’s feasibility and effectiveness. Great breakthroughs have been made both in theoretical research and engineering prototype development.
- 21 September 2023
- Published by MDPI AG in Electronics
- Vol. 12 (18) , 3975
Open AccessA High-Power Density DC Converter for Medium-Voltage DC Distribution Networks
A DC converter is the core equipment of voltage conversion and power distribution in a DC distribution network. Its operating characteristics have a profound impact on the flexible regulation of distributed resources in an active distribution network. It is challenging for the existing single-stage conversion topology to meet the requirements of distributed renewable energy connected to a multi-voltage level, medium-voltage grid. It is necessary to study the multistage transform power unit topology further, which can satisfy high reliability, high efficiency, and wide input range. This paper proposes a high-power density DC converter for medium-voltage DC networks with wide voltage levels. It adopts Buck-LLC integrated modular composition. The input ends of the high isolation resonant power unit are connected in series to provide high voltage endurance, and the output ends are connected in parallel to meet the high-power demand and achieve high-power transmission efficiency. The proposed series dual Buck-LLC resonant power unit topology can adjust the duty cycle of series dual buck circuits to meet the needs of different levels of medium-voltage DC power grids. The soft switching problem within the wide input range of all switching tubes is solved by introducing auxiliary inductors, thereby improving energy transmission efficiency. The auxiliary circuit and control parameters are optimized based on the research of each switching tube’s soft switching boundary conditions. Finally, an experimental prototype of a 6.25~7 kW power unit is designed and developed to prove the proposed topology’s feasibility and effectiveness. Great breakthroughs have been made both in theoretical research and engineering prototype development.
- Open Access
- 15 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13800
Fast and Robust State Estimation for Active Distribution Networks Considering Measurement Data Fusion and Network Topology Changes
With the integration of distributed generations (DGs), distribution networks are being transformed into active distribution networks (ADNs). Due to ADNs‘ complex operational scenarios, massive data, and fast-changing network topologies, traditional state-estimation (SE) methods are inadequate to meet the requirements of computational accuracy, computational speed, and robustness. Aiming at the SE of ADNs, this paper proposes a data-driven and classic-model-integrated SE method, which uses an SE neural network (NN) to perform an initial estimation, and then uses linear SE to refine the estimation. It applies PMU and SCADA data fusion and is robust to noise and ADN topology changes. The simulations on the IEEE standard system verify that the proposed method is superior to traditional SE methods in terms of estimation accuracy, calculation speed, and robustness. This study provides ADNS with a new effective estimation scheme, which is of great significance in the context of promoting the development of renewable energy.
- 15 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13800
Open AccessFast and Robust State Estimation for Active Distribution Networks Considering Measurement Data Fusion and Network Topology Changes
With the integration of distributed generations (DGs), distribution networks are being transformed into active distribution networks (ADNs). Due to ADNs‘ complex operational scenarios, massive data, and fast-changing network topologies, traditional state-estimation (SE) methods are inadequate to meet the requirements of computational accuracy, computational speed, and robustness. Aiming at the SE of ADNs, this paper proposes a data-driven and classic-model-integrated SE method, which uses an SE neural network (NN) to perform an initial estimation, and then uses linear SE to refine the estimation. It applies PMU and SCADA data fusion and is robust to noise and ADN topology changes. The simulations on the IEEE standard system verify that the proposed method is superior to traditional SE methods in terms of estimation accuracy, calculation speed, and robustness. This study provides ADNS with a new effective estimation scheme, which is of great significance in the context of promoting the development of renewable energy.