Hao Zhen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hao Zhen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Feng Liu
School of Future Transportation, Guangzhou Maritime University, Guangzhou 510725, China
3 shared publications - Lijuan Li
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
3 shared publications - Hongming Li
Guangdong Zhongdu Construction Group Co., Ltd., Lianjiang 524499, China
2 shared publications - Zezhou Pan
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
2 shared publications - Zhe Xiong
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
2 shared publications - Zhichao Wu
Guangdong Zhongdu Construction Group Co., Ltd., Lianjiang 524499, China
2 shared publications
Latest Publications
- Open Access
Experimental and Theoretical Study on Tensile Mechanical Properties of GFRP–Steel Composite Bars
Glass-fiber-reinforced polymer (GFRP)–steel composite bar, a novel building material, is a promising longitudinal reinforcement for marine engineering in harsh environments. Previous research has primarily focused on altering individual parameters to assess their influence on the performance of composite bars, lacking a systematic and in-depth exploration. In this paper, the tensile properties of composite bars have been investigated by adequate experimental testing considering the type of inner steel bar and the thickness of the GFRP layer. Results show that although composite bars undergo elasticity, hardening, and failure stages under tensile loading, due to differences in interfacial bonding forces, the ultimate failure mode for composite bars with HPB300 inner steel bars is relative slippage, while for those with HRB400 inner steel bars, it is fracturing. While ensuring that composite bars have good initial elastic modulus and durability, it is preferable for the thickness of the external GFRP layer to be as small as possible. However, the thickness of the external GFRP layer of composite bars should not be less than 2 mm to prevent misalignment of the inner steel bars, which can negatively impact the tangent modulus during the hardening stage and the ultimate tensile strength. Furthermore, a stress–strain constitutive model for this composite bar was developed and validated. This model offers a universal framework for accurately representing the mechanical properties of the material across a wide range of research parameters.
Open AccessExperimental and Theoretical Study on Tensile Mechanical Properties of GFRP–Steel Composite Bars
Glass-fiber-reinforced polymer (GFRP)–steel composite bar, a novel building material, is a promising longitudinal reinforcement for marine engineering in harsh environments. Previous research has primarily focused on altering individual parameters to assess their influence on the performance of composite bars, lacking a systematic and in-depth exploration. In this paper, the tensile properties of composite bars have been investigated by adequate experimental testing considering the type of inner steel bar and the thickness of the GFRP layer. Results show that although composite bars undergo elasticity, hardening, and failure stages under tensile loading, due to differences in interfacial bonding forces, the ultimate failure mode for composite bars with HPB300 inner steel bars is relative slippage, while for those with HRB400 inner steel bars, it is fracturing. While ensuring that composite bars have good initial elastic modulus and durability, it is preferable for the thickness of the external GFRP layer to be as small as possible. However, the thickness of the external GFRP layer of composite bars should not be less than 2 mm to prevent misalignment of the inner steel bars, which can negatively impact the tangent modulus during the hardening stage and the ultimate tensile strength. Furthermore, a stress–strain constitutive model for this composite bar was developed and validated. This model offers a universal framework for accurately representing the mechanical properties of the material across a wide range of research parameters.
- Open Access
Combined Effects of Steel and Glass Fibres on the Fracture Performance of Recycled Rubber Concrete
As an environmentally friendly construction material, recycled rubber concrete (RRC) is commonly used as a road material owing to its excellent flexural strength and crack resistance. Previous studies have shown that the addition of fibres is an effective method for improving the crack resistance of concrete. The purpose of this study is to investigate the fracture performance of RRC reinforced with steel fibres (SFs) and glass fibres (GFs). A total of 28 RRC mixtures were prepared. The results of the fracture test showed that the addition of SFs and GFs significantly enhanced the RRC fracture performance. The maximum increases or decreases in flexural strength, brittleness coefficient, fracture energy, initial fracture toughness, and unstable fracture toughness were 64.9, −34.6, 775.6, 92.0, and 118.4%, respectively. The ideal GF content is usually in the range of 0.4–0.6% and decreases with increasing SF content. In addition, scanning electron microscope (SEM) tests were conducted to explore the mechanism of the effect of hybrid fibres on RRC at a microscopic level. The results show that SFs were always pulled out, while GFs were pulled apart at the initial defects. At the same time, excessive GFs caused more initial defects. These results are expected to provide theoretical direction and experimental support for the practical application of hybrid fibre-reinforced recycled rubber concrete (HFRRRC).
Open AccessCombined Effects of Steel and Glass Fibres on the Fracture Performance of Recycled Rubber Concrete
As an environmentally friendly construction material, recycled rubber concrete (RRC) is commonly used as a road material owing to its excellent flexural strength and crack resistance. Previous studies have shown that the addition of fibres is an effective method for improving the crack resistance of concrete. The purpose of this study is to investigate the fracture performance of RRC reinforced with steel fibres (SFs) and glass fibres (GFs). A total of 28 RRC mixtures were prepared. The results of the fracture test showed that the addition of SFs and GFs significantly enhanced the RRC fracture performance. The maximum increases or decreases in flexural strength, brittleness coefficient, fracture energy, initial fracture toughness, and unstable fracture toughness were 64.9, −34.6, 775.6, 92.0, and 118.4%, respectively. The ideal GF content is usually in the range of 0.4–0.6% and decreases with increasing SF content. In addition, scanning electron microscope (SEM) tests were conducted to explore the mechanism of the effect of hybrid fibres on RRC at a microscopic level. The results show that SFs were always pulled out, while GFs were pulled apart at the initial defects. At the same time, excessive GFs caused more initial defects. These results are expected to provide theoretical direction and experimental support for the practical application of hybrid fibre-reinforced recycled rubber concrete (HFRRRC).
- Open Access
Experimental Investigation on the Seismic Behavior of Precast Concrete Beam-Column Joints with Five-Spiral Stirrups
Precast concrete structure is a low-carbon building system that has been attracting extensive attention in recent decades. Beam–column joints are the weak links in precast concrete structures. Past studies showed that the five-spiral stirrups had excellent confinement effects and had the potential to enhance the seismic performance of concrete structures. This study proposed the reinforcement of precast concrete beam–column joints by using five-spiral stirrups and investigated their seismic performance. Considering the influences of the joint failure mode, joint type, construction method, and stirrup type, low-cycle loading tests were conducted on six full-scale precast concrete beam–column joint specimens. Various seismic behavior indicators, such as failure modes, hysteresis curves, skeleton curves, ductility, and energy dissipation, were obtained. The results indicated that the deformation capacity of the precast joints with five-spiral stirrups was comparable to that of cast-in-place joints. Under different failure design criteria, the seismic performance of the precast joints was superior to that of cast-in-place joints. Furthermore, the experimental capacities of the precast joints, using five-spiral stirrups, were higher than the calculated values according to the design code, demonstrating an adequate safety margin. This research contributes to the development of low-carbon and sustainable construction practices in the field of precast concrete structures.
Open AccessExperimental Investigation on the Seismic Behavior of Precast Concrete Beam-Column Joints with Five-Spiral Stirrups
Precast concrete structure is a low-carbon building system that has been attracting extensive attention in recent decades. Beam–column joints are the weak links in precast concrete structures. Past studies showed that the five-spiral stirrups had excellent confinement effects and had the potential to enhance the seismic performance of concrete structures. This study proposed the reinforcement of precast concrete beam–column joints by using five-spiral stirrups and investigated their seismic performance. Considering the influences of the joint failure mode, joint type, construction method, and stirrup type, low-cycle loading tests were conducted on six full-scale precast concrete beam–column joint specimens. Various seismic behavior indicators, such as failure modes, hysteresis curves, skeleton curves, ductility, and energy dissipation, were obtained. The results indicated that the deformation capacity of the precast joints with five-spiral stirrups was comparable to that of cast-in-place joints. Under different failure design criteria, the seismic performance of the precast joints was superior to that of cast-in-place joints. Furthermore, the experimental capacities of the precast joints, using five-spiral stirrups, were higher than the calculated values according to the design code, demonstrating an adequate safety margin. This research contributes to the development of low-carbon and sustainable construction practices in the field of precast concrete structures.