Biswarup Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Biswarup Das has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Kandukuri Surendra
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
3 shared publications - Anubrata Dey
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
2 shared publications - Ashish Kumar Mishra
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, India
2 shared publications Mohd Tauhid Alam
2 shared publications- Ravi Varma Chavali
SRM University-AP
2 shared publications Vinay Pant
2 shared publications
Latest Publications
- 24 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 257
Power flow analysis of parallel AT-fed double-track high speed traction network
- 24 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 257
Power flow analysis of parallel AT-fed double-track high speed traction network
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 7880-7891
Interval Load Flow for Islanded AC and Hybrid AC/DC Microgrids With Load Uncertainties
The islanded mode of AC and hybrid AC/DC microgrids enhances the reliability and resiliency of distribution systems by enabling the use of local Distributed Generators (DGs) during abnormal conditions such as grid faults, weather events, and cyber attacks. Islanded AC Microgrids (IMGs) and Islanded Hybrid AC/DC microgrids (IHMGs) require a specialized modeling approach compared to grid-connected microgrids due to the implementation of droop control for DGs, where active power is regulated through frequency ($\omega$) and reactive power through bus voltage (V). In IHMGs, power sharing among DGs in the DC microgrid is controlled through their respective bus voltages, while the power exchange between AC and DC microgrids is managed using Interlinking Converter (IC). The IC droop control uses the AC microgrid frequency and DC bus voltages for power balance in IHMG. This droop control is modeled using droop equations for system studies. This article presents interval load flow models that account for the unique features of droop control and islanded operation. The integration of renewable energy sources, electric vehicles, storage, and power electronic loads introduces uncertainty in the load demands of IMGs and IHMGs, which are treated as interval quantities, with load flow models solved as optimization problems. The solutions of the interval load flow models for IMGs and IHMGs are validated by comparing them with results from Monte Carlo Simulation studies (MCS). Through various case studies on IMGs and IHMGs, the scalability and efficacy of the interval approach for managing load uncertainty in these microgrids has been demonstrated.
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 7880-7891
Interval Load Flow for Islanded AC and Hybrid AC/DC Microgrids With Load Uncertainties
The islanded mode of AC and hybrid AC/DC microgrids enhances the reliability and resiliency of distribution systems by enabling the use of local Distributed Generators (DGs) during abnormal conditions such as grid faults, weather events, and cyber attacks. Islanded AC Microgrids (IMGs) and Islanded Hybrid AC/DC microgrids (IHMGs) require a specialized modeling approach compared to grid-connected microgrids due to the implementation of droop control for DGs, where active power is regulated through frequency ($\omega$) and reactive power through bus voltage (V). In IHMGs, power sharing among DGs in the DC microgrid is controlled through their respective bus voltages, while the power exchange between AC and DC microgrids is managed using Interlinking Converter (IC). The IC droop control uses the AC microgrid frequency and DC bus voltages for power balance in IHMG. This droop control is modeled using droop equations for system studies. This article presents interval load flow models that account for the unique features of droop control and islanded operation. The integration of renewable energy sources, electric vehicles, storage, and power electronic loads introduces uncertainty in the load demands of IMGs and IHMGs, which are treated as interval quantities, with load flow models solved as optimization problems. The solutions of the interval load flow models for IMGs and IHMGs are validated by comparing them with results from Monte Carlo Simulation studies (MCS). Through various case studies on IMGs and IHMGs, the scalability and efficacy of the interval approach for managing load uncertainty in these microgrids has been demonstrated.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 5537-5548
A Novel Density Based Clustering Approach for Electricity Theft Detection
The extensive integration of advanced metering infrastructure (AMI) has transformed the landscape of electricity consumption monitoring, providing an effective avenue to address electricity theft by scrutinizing data obtained from smart meters. This research utilises the AMI data to detect instances of electricity theft by employing a novel unsupervised data-driven clustering technique called Hierarchical Density-Based Spatial Clustering of Applications with Noise (HDBSCAN). The advantage of HDBSCAN in identifying points that do not conform to any cluster, commonly termed as noise points, becomes particularly pertinent in the context of theft detection. These noise points represent potential anomalies or irregularities in electricity consumption patterns, which are crucial for identifying and investigating suspicious activities. Leveraging HDBSCAN for outlier detection enhances the effectiveness of theft detection mechanisms by enabling the identification of data points that deviate significantly from the expected consumption patterns, thereby enhancing the security and integrity of electricity distribution networks. The proposed methodology requires consumption data from smart meters located at consumers premises only. The metering data undergo pre-processing, which encompasses tasks such as recovering missing and erroneous values, as well as normalization, ensuring the accuracy and reliability of the analysis. Furthermore, in our work, we have integrated Density Based Clustering Validation (DBCV) technique for the purpose of hyperparameter tuning, ensuring optimal performance and robustness of the proposed approach. The method was rigorously tested on two real-world datasets, and the results demonstrated robust performance across various evaluation metrics.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 5537-5548
A Novel Density Based Clustering Approach for Electricity Theft Detection
The extensive integration of advanced metering infrastructure (AMI) has transformed the landscape of electricity consumption monitoring, providing an effective avenue to address electricity theft by scrutinizing data obtained from smart meters. This research utilises the AMI data to detect instances of electricity theft by employing a novel unsupervised data-driven clustering technique called Hierarchical Density-Based Spatial Clustering of Applications with Noise (HDBSCAN). The advantage of HDBSCAN in identifying points that do not conform to any cluster, commonly termed as noise points, becomes particularly pertinent in the context of theft detection. These noise points represent potential anomalies or irregularities in electricity consumption patterns, which are crucial for identifying and investigating suspicious activities. Leveraging HDBSCAN for outlier detection enhances the effectiveness of theft detection mechanisms by enabling the identification of data points that deviate significantly from the expected consumption patterns, thereby enhancing the security and integrity of electricity distribution networks. The proposed methodology requires consumption data from smart meters located at consumers premises only. The metering data undergo pre-processing, which encompasses tasks such as recovering missing and erroneous values, as well as normalization, ensuring the accuracy and reliability of the analysis. Furthermore, in our work, we have integrated Density Based Clustering Validation (DBCV) technique for the purpose of hyperparameter tuning, ensuring optimal performance and robustness of the proposed approach. The method was rigorously tested on two real-world datasets, and the results demonstrated robust performance across various evaluation metrics.
- 26 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 1159-1169
An abc Reference Frame Hysteresis Current Controller for Grid Connected Converter With Constant Switching Frequency Operation
For a grid-connected inverter, a constant switching frequency hysteresis current control (HCC) technique based on targeted trajectory of current space vector (HCC-TTCSV) is proposed. The harmonic spectrum of inverter line-to-line voltage, produced by the proposed HCC-TTCSV, is ensured to exhibit similar characteristics to that of voltage-controlled conventional seven-segment space vector modulation (SVM) technique. The proposed current controller is a novel one (i.e., first of its kind) that allows the phase currents to be checked with online calculated current boundaries in stationary abc reference frame. Instead of following a current error boundary, phase current boundary check is performed. The phase current boundary values during every seven-segment switching cycle, however, are found out by observing the projections of vertices of targeted trajectory of current vector along abc axes using few trigonometric relations. The proposed controller is designed for three-phase two-level voltage-source inverter (2L-VSI), and it works well for both L filter and LCL filter. Compensation methods to overcome the current distraction effect caused by factors such as finite rate of current sampling, dead time, gate driver circuit's propagation time, and other nonidealities of the system are also discussed in detail. Theoretical background is established, and experimental verification is presented for validation.
- 26 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 1159-1169
An abc Reference Frame Hysteresis Current Controller for Grid Connected Converter With Constant Switching Frequency Operation
For a grid-connected inverter, a constant switching frequency hysteresis current control (HCC) technique based on targeted trajectory of current space vector (HCC-TTCSV) is proposed. The harmonic spectrum of inverter line-to-line voltage, produced by the proposed HCC-TTCSV, is ensured to exhibit similar characteristics to that of voltage-controlled conventional seven-segment space vector modulation (SVM) technique. The proposed current controller is a novel one (i.e., first of its kind) that allows the phase currents to be checked with online calculated current boundaries in stationary abc reference frame. Instead of following a current error boundary, phase current boundary check is performed. The phase current boundary values during every seven-segment switching cycle, however, are found out by observing the projections of vertices of targeted trajectory of current vector along abc axes using few trigonometric relations. The proposed controller is designed for three-phase two-level voltage-source inverter (2L-VSI), and it works well for both L filter and LCL filter. Compensation methods to overcome the current distraction effect caused by factors such as finite rate of current sampling, dead time, gate driver circuit's propagation time, and other nonidealities of the system are also discussed in detail. Theoretical background is established, and experimental verification is presented for validation.
- 1 March 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 230
A scheme for electricity theft detection based on EWMA control chart
- 1 March 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 230
A scheme for electricity theft detection based on EWMA control chart
- 18 January 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 229
Decoupled state and line parameter estimation in three-phase unbalanced distribution system
- 18 January 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 229
Decoupled state and line parameter estimation in three-phase unbalanced distribution system
- Open Access
- 5 November 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 155
Static state estimation of islanded AC/DC Hybrid microgrids
- 5 November 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 155
Open AccessStatic state estimation of islanded AC/DC Hybrid microgrids
- 15 September 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 225
Combined static state and frequency estimation in an islanded AC microgrid with limited SCADA measurements
- 15 September 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 225
Combined static state and frequency estimation in an islanded AC microgrid with limited SCADA measurements