Melissa A. Morris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Melissa A. Morris has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Douglas A. Day
Department of Chemistry, University of Colorado Boulder, Boulder, CO 80309, USA
19 shared publications - Jose Luis Jimenez
University of Colorado
19 shared publications - Joost A. de Gouw
Cooperative Institute for Research in Environmental Sciences, University of Colorado Boulder, Boulder, CO, 80309, USA
16 shared publications - Demetrios Pagonis
Department of Chemistry
9 shared publications - Paul J. Ziemann
Department of Chemistry, University of Colorado, Boulder, Colorado 80309, United States
9 shared publications - Pedro Campuzano-Jost
University of Colorado Boulder, Boulder, Colorado, USA
8 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by Copernicus GmbH in Aerosol Research
- Vol. 4 (2) , 517-546
Measurements and modeling of urban secondary organic aerosol formation potential as a function of precursor volatility class in the Los Angeles area during summer 2022
Urban secondary organic aerosol (SOA) contributes to degraded air quality, which can affect human health. Improvements in Los Angeles (LA), CA, air quality have mainly plateaued since 2010. In summer 2022, measurements were made to quantify the SOA formation potential (SOA-FP) in ambient LA air. Two oxidation flow reactors (OFRs) ingested ambient air: one was equipped with an electrically conductive polymer inlet that denuded lower-volatility species, and the other was run without an inlet. This allowed the separate quantification of SOA-FP from higher- vs. lower-volatility precursors. To our knowledge these are the first direct measurements of these fractions. Measured ambient SOA was similar, and total SOA-FP was lower in 2022 vs. 2010, consistent with higher ambient OH causing greater consumptions of SOA precursors in 2022. The dual-OFR measurements suggest ∼ 31 % of the total SOA-FP is due to compounds with volatilities in the semi-volatile organic compound (SVOC) and lower intermediate-volatility organic compound (IVOC) ranges. Evidence suggests these lower-volatility precursors are mainly from direct emissions, rather than oxidation products from upwind aging. Results are compared to two box models: one based on CRACMM and the other adapted from a recent Caltech publication. CRACMM predicted ambient OA well but underpredicted SOA-FP by about a factor of 2, while the Caltech model underestimated OA and overpredicted SOA-FP by a factor of 2.5. Our study finds terpenoids contribute to, but do not dominate, SOA-FP.
- 30 October 2026
- Published by Copernicus GmbH in Aerosol Research
- Vol. 4 (2) , 517-546
Open AccessMeasurements and modeling of urban secondary organic aerosol formation potential as a function of precursor volatility class in the Los Angeles area during summer 2022
Urban secondary organic aerosol (SOA) contributes to degraded air quality, which can affect human health. Improvements in Los Angeles (LA), CA, air quality have mainly plateaued since 2010. In summer 2022, measurements were made to quantify the SOA formation potential (SOA-FP) in ambient LA air. Two oxidation flow reactors (OFRs) ingested ambient air: one was equipped with an electrically conductive polymer inlet that denuded lower-volatility species, and the other was run without an inlet. This allowed the separate quantification of SOA-FP from higher- vs. lower-volatility precursors. To our knowledge these are the first direct measurements of these fractions. Measured ambient SOA was similar, and total SOA-FP was lower in 2022 vs. 2010, consistent with higher ambient OH causing greater consumptions of SOA precursors in 2022. The dual-OFR measurements suggest ∼ 31 % of the total SOA-FP is due to compounds with volatilities in the semi-volatile organic compound (SVOC) and lower intermediate-volatility organic compound (IVOC) ranges. Evidence suggests these lower-volatility precursors are mainly from direct emissions, rather than oxidation products from upwind aging. Results are compared to two box models: one based on CRACMM and the other adapted from a recent Caltech publication. CRACMM predicted ambient OA well but underpredicted SOA-FP by about a factor of 2, while the Caltech model underestimated OA and overpredicted SOA-FP by a factor of 2.5. Our study finds terpenoids contribute to, but do not dominate, SOA-FP.
- Open Access
- 23 June 2026
- Published by Copernicus GmbH
- p. 1-45
Comment on ar-2026-12
Urban secondary organic aerosol (SOA) contributes to degraded air quality which can affect human health. Improvements in Los Angeles (LA), CA air quality have mainly plateaued since 2010. In summer 2022, measurements were made to quantify the SOA formation potential (SOA-FP) in ambient LA air. Two oxidation flow reactors (OFRs) ingested ambient air: one was equipped with an electrically conductive polymer inlet that denuded lower volatility species, and the other was run without an inlet. This allowed the separate quantification of SOA-FP from higher vs. lower volatility precursors. To our knowledge these are the first direct measurements of these fractions. Measured ambient SOA was similar and total SOA-FP was lower in 2022 vs. 2010, consistent with higher ambient OH causing greater consumptions of SOA precursors in 2022. The dual-OFR measurements suggest ~31 % of the total SOA-FP is due to compounds with volatilities in the SVOC and lower IVOC ranges. Results are compared to two box models: one based on CRACMM and the other adapted from a recent Caltech publication. CRACMM predicted ambient OA well but underpredicted SOA-FP by about a factor of 2, while the Caltech model underestimated OA and overpredicted SOA-FP by a factor of 2.5. Our study finds terpenoids contribute to, but do not dominate, SOA-FP.
- 23 June 2026
- Published by Copernicus GmbH
- p. 1-45
Open AccessComment on ar-2026-12
Urban secondary organic aerosol (SOA) contributes to degraded air quality which can affect human health. Improvements in Los Angeles (LA), CA air quality have mainly plateaued since 2010. In summer 2022, measurements were made to quantify the SOA formation potential (SOA-FP) in ambient LA air. Two oxidation flow reactors (OFRs) ingested ambient air: one was equipped with an electrically conductive polymer inlet that denuded lower volatility species, and the other was run without an inlet. This allowed the separate quantification of SOA-FP from higher vs. lower volatility precursors. To our knowledge these are the first direct measurements of these fractions. Measured ambient SOA was similar and total SOA-FP was lower in 2022 vs. 2010, consistent with higher ambient OH causing greater consumptions of SOA precursors in 2022. The dual-OFR measurements suggest ~31 % of the total SOA-FP is due to compounds with volatilities in the SVOC and lower IVOC ranges. Results are compared to two box models: one based on CRACMM and the other adapted from a recent Caltech publication. CRACMM predicted ambient OA well but underpredicted SOA-FP by about a factor of 2, while the Caltech model underestimated OA and overpredicted SOA-FP by a factor of 2.5. Our study finds terpenoids contribute to, but do not dominate, SOA-FP.
- Open Access
- 20 March 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-45
Measurements and modeling of urban secondary organic aerosol formation potential as a function of precursor volatility class in the Los Angeles area during summer 2022
Urban secondary organic aerosol (SOA) contributes to degraded air quality which can affect human health. Improvements in Los Angeles (LA), CA air quality have mainly plateaued since 2010. In summer 2022, measurements were made to quantify the SOA formation potential (SOA-FP) in ambient LA air. Two oxidation flow reactors (OFRs) ingested ambient air: one was equipped with an electrically conductive polymer inlet that denuded lower volatility species, and the other was run without an inlet. This allowed the separate quantification of SOA-FP from higher vs. lower volatility precursors. To our knowledge these are the first direct measurements of these fractions. Measured ambient SOA was similar and total SOA-FP was lower in 2022 vs. 2010, consistent with higher ambient OH causing greater consumptions of SOA precursors in 2022. The dual-OFR measurements suggest ~31 % of the total SOA-FP is due to compounds with volatilities in the SVOC and lower IVOC ranges. Results are compared to two box models: one based on CRACMM and the other adapted from a recent Caltech publication. CRACMM predicted ambient OA well but underpredicted SOA-FP by about a factor of 2, while the Caltech model underestimated OA and overpredicted SOA-FP by a factor of 2.5. Our study finds terpenoids contribute to, but do not dominate, SOA-FP.
- 20 March 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-45
Open AccessMeasurements and modeling of urban secondary organic aerosol formation potential as a function of precursor volatility class in the Los Angeles area during summer 2022
Urban secondary organic aerosol (SOA) contributes to degraded air quality which can affect human health. Improvements in Los Angeles (LA), CA air quality have mainly plateaued since 2010. In summer 2022, measurements were made to quantify the SOA formation potential (SOA-FP) in ambient LA air. Two oxidation flow reactors (OFRs) ingested ambient air: one was equipped with an electrically conductive polymer inlet that denuded lower volatility species, and the other was run without an inlet. This allowed the separate quantification of SOA-FP from higher vs. lower volatility precursors. To our knowledge these are the first direct measurements of these fractions. Measured ambient SOA was similar and total SOA-FP was lower in 2022 vs. 2010, consistent with higher ambient OH causing greater consumptions of SOA precursors in 2022. The dual-OFR measurements suggest ~31 % of the total SOA-FP is due to compounds with volatilities in the SVOC and lower IVOC ranges. Results are compared to two box models: one based on CRACMM and the other adapted from a recent Caltech publication. CRACMM predicted ambient OA well but underpredicted SOA-FP by about a factor of 2, while the Caltech model underestimated OA and overpredicted SOA-FP by a factor of 2.5. Our study finds terpenoids contribute to, but do not dominate, SOA-FP.
- 31 December 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (2) , 313-325
Complex Effects of Reduced Mobile Source Emissions on Submicron Particulate Matter Concentrations in Los Angeles
Despite considerable reductions in mobile source emissions, annual average aerosol concentrations measured in Los Angeles using Federal Reference Methods (FRM) have not appreciably declined over the last decade. Here, we use submicron aerosol measurements and zero-dimensional modeling to quantify the impacts of these emissions reductions on aerosol formation in Pasadena, CA during the late spring and summer of 2022. Reductions in secondary organic aerosol (SOA) concentrations expected from reduced mobile source emissions appear to have been largely offset by increases in hydroxyl radical concentrations, an indirect effect of reduced nitrogen oxide (NOx) emissions. As a result, while the predicted contribution of mobile sources to the SOA burden has declined from ~50% in 2010 to only ~25% in 2022, concentrations of locally-formed SOA have remained relatively constant. In contrast, reductions in mobile source NOx emissions have likely reduced overnight production of nitric acid and ammonium nitrate (AN) aerosol. We provide indirect evidence that FRM measurements may have failed to capture the reduction in AN since 2010 due to evaporation of semi-volatile species from FRM filter samples. Our results suggest that given the effectiveness of historical regulatory efforts aimed at mobile sources, and on-road sources in particular, additional reductions in submicron aerosol concentrations in Los Angeles will likely require increased focus on abating emissions from non-road and area sources.
- 31 December 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (2) , 313-325
Complex Effects of Reduced Mobile Source Emissions on Submicron Particulate Matter Concentrations in Los Angeles
Despite considerable reductions in mobile source emissions, annual average aerosol concentrations measured in Los Angeles using Federal Reference Methods (FRM) have not appreciably declined over the last decade. Here, we use submicron aerosol measurements and zero-dimensional modeling to quantify the impacts of these emissions reductions on aerosol formation in Pasadena, CA during the late spring and summer of 2022. Reductions in secondary organic aerosol (SOA) concentrations expected from reduced mobile source emissions appear to have been largely offset by increases in hydroxyl radical concentrations, an indirect effect of reduced nitrogen oxide (NOx) emissions. As a result, while the predicted contribution of mobile sources to the SOA burden has declined from ~50% in 2010 to only ~25% in 2022, concentrations of locally-formed SOA have remained relatively constant. In contrast, reductions in mobile source NOx emissions have likely reduced overnight production of nitric acid and ammonium nitrate (AN) aerosol. We provide indirect evidence that FRM measurements may have failed to capture the reduction in AN since 2010 due to evaporation of semi-volatile species from FRM filter samples. Our results suggest that given the effectiveness of historical regulatory efforts aimed at mobile sources, and on-road sources in particular, additional reductions in submicron aerosol concentrations in Los Angeles will likely require increased focus on abating emissions from non-road and area sources.
- Open Access
- 8 April 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Mitigation of indoor air pollution from air cleaners using a catalyst
The COVID-19 pandemic highlighted the importance of indoor air quality and the role of airborne transmission in disease spread. Heightened public awareness led to an increase in the commercialization and use of air cleaners. While several of these devices effectively disinfect the air, some also initiate chemical reactions that can worsen indoor air quality by generating ozone (O3) and other harmful air pollutants. Here we demonstrate the use of a catalyst to mitigate both air cleaner-generated and ambient pollution in a real indoor environment. We deployed two real-time chemical ionization mass spectrometers alongside a suite of air quality analyzers to measure a wide range of volatile organic compounds (VOCs), other trace gases, and particles. We show the reduction of many indoor pollutants, including O3, nitrogen oxides, formaldehyde, and other oxidized VOCs. We observe an increase in the concentrations of more reduced VOCs with catalyst use. We demonstrate that over 16 weeks of continuous operation, the clean air delivery rate of the catalyst for O3 pollution declined linearly by 12.5%. These findings suggest that employing a dedicated catalyst could reduce indoor air pollution and enhance the human health benefits of air cleaners by minimizing the associated indoor air quality risks.
- 8 April 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessMitigation of indoor air pollution from air cleaners using a catalyst
The COVID-19 pandemic highlighted the importance of indoor air quality and the role of airborne transmission in disease spread. Heightened public awareness led to an increase in the commercialization and use of air cleaners. While several of these devices effectively disinfect the air, some also initiate chemical reactions that can worsen indoor air quality by generating ozone (O3) and other harmful air pollutants. Here we demonstrate the use of a catalyst to mitigate both air cleaner-generated and ambient pollution in a real indoor environment. We deployed two real-time chemical ionization mass spectrometers alongside a suite of air quality analyzers to measure a wide range of volatile organic compounds (VOCs), other trace gases, and particles. We show the reduction of many indoor pollutants, including O3, nitrogen oxides, formaldehyde, and other oxidized VOCs. We observe an increase in the concentrations of more reduced VOCs with catalyst use. We demonstrate that over 16 weeks of continuous operation, the clean air delivery rate of the catalyst for O3 pollution declined linearly by 12.5%. These findings suggest that employing a dedicated catalyst could reduce indoor air pollution and enhance the human health benefits of air cleaners by minimizing the associated indoor air quality risks.
- 23 December 2024
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 129 (24)
Emissions and Chemistry of Volatile Organic Compounds in the Los Angeles Basin in Summer 2022
The ozone air quality standard is regularly surpassed in the Los Angeles air basin, and efforts to mitigate ozone production have targeted emissions of precursor volatile organic compounds (VOCs), especially from mobile sources. In order to assess how VOC concentrations, emissions, and chemistry have changed over the past decade, VOCs were measured in this study using a Vocus‐2R proton‐transfer reaction time‐of‐flight mass spectrometer in Pasadena, California, downwind of Los Angeles, in summer 2022. Relative to 2010, ambient concentrations of aromatic hydrocarbons have declined at a similar rate as carbon monoxide, suggesting reduced overall emissions from mobile sources. However, the ambient concentrations of oxygenated VOCs have remained similar or increased, suggesting a greater relative importance of oxidation products and other emission sources, such as volatile chemical products whose emissions are largely unregulated. Relative to 2010, the range of measured VOCs was expanded, including higher aromatics and additional volatile chemical products, allowing a better understanding of a wider range of emission sources. Emission ratios relative to carbon monoxide were estimated and compared with 2010 emission ratios. Average measured ozone concentrations were generally comparable between 2022 and 2010; however, at the same temperature, daytime ozone concentrations were lower in 2022 than 2010. Faster photochemistry was observed in 2022, with average hydroxyl radical exposure being ∼68% higher during midday (statistically significant at 95% confidence), although this difference reduces to ∼35% when comparing observations at ambient temperatures of 25–30°C only. Future trends in temperature are important in predicting ozone production.
- 23 December 2024
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 129 (24)
Emissions and Chemistry of Volatile Organic Compounds in the Los Angeles Basin in Summer 2022
The ozone air quality standard is regularly surpassed in the Los Angeles air basin, and efforts to mitigate ozone production have targeted emissions of precursor volatile organic compounds (VOCs), especially from mobile sources. In order to assess how VOC concentrations, emissions, and chemistry have changed over the past decade, VOCs were measured in this study using a Vocus‐2R proton‐transfer reaction time‐of‐flight mass spectrometer in Pasadena, California, downwind of Los Angeles, in summer 2022. Relative to 2010, ambient concentrations of aromatic hydrocarbons have declined at a similar rate as carbon monoxide, suggesting reduced overall emissions from mobile sources. However, the ambient concentrations of oxygenated VOCs have remained similar or increased, suggesting a greater relative importance of oxidation products and other emission sources, such as volatile chemical products whose emissions are largely unregulated. Relative to 2010, the range of measured VOCs was expanded, including higher aromatics and additional volatile chemical products, allowing a better understanding of a wider range of emission sources. Emission ratios relative to carbon monoxide were estimated and compared with 2010 emission ratios. Average measured ozone concentrations were generally comparable between 2022 and 2010; however, at the same temperature, daytime ozone concentrations were lower in 2022 than 2010. Faster photochemistry was observed in 2022, with average hydroxyl radical exposure being ∼68% higher during midday (statistically significant at 95% confidence), although this difference reduces to ∼35% when comparing observations at ambient temperatures of 25–30°C only. Future trends in temperature are important in predicting ozone production.
- Open Access
- 27 August 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (16) , 4915-4939
A comprehensive evaluation of enhanced temperature influence on gas and aerosol chemistry in the lamp-enclosed oxidation flow reactor (OFR) system
Oxidation flow reactors (OFRs) have been extensively utilized to examine the formation of secondary organic aerosol (SOA). However, the UV lamps typically employed to initiate the photochemistry in OFRs can result in an elevated reactor temperature when their implications are not thoroughly evaluated. In this study, we conducted a comprehensive investigation into the temperature distribution within an Aerodyne potential aerosol mass OFR (PAM-OFR) and then examined the subsequent effects on flow and chemistry due to lamp heating. A lamp-induced temperature increase was observed, which was a function of lamp-driving voltage, number of lamps, lamp types, OFR residence time, and positions within the PAM-OFR. Under typical PAM-OFR operational conditions (e.g., < 5 d of equivalent atmospheric OH exposure under low-NOx conditions), the temperature increase typically ranged from 1–5 °C. Under extreme (but less frequently encountered) conditions, the heating could reach up to 15 °C. The influences of the increased temperature over ambient conditions on the flow distribution, gas, and condensed-phase chemistry within PAM-OFR were evaluated. Our findings indicate that the increase in temperature altered the flow field, resulting in a diminished tail on the residence time distribution and corresponding oxidant exposure due to faster recirculation. According to simulation results from a radical chemistry box model, the variation in absolute oxidant concentration within PAM-OFR due to temperature increase was minimal (< 5 %). The temperature influences on seed organic aerosol (OA) and newly formed secondary OA were also investigated, suggesting that an increase in temperature can impact the yield, size, and oxidation levels of representative biogenic and anthropogenic SOA types. Recommendations for temperature-dependent SOA yield corrections and PAM-OFR operating protocols that mitigate lamp-induced temperature enhancement and fluctuations are presented. We recommend blowing air around the reactor's exterior with fans during PAM-OFR experiments to minimize the temperature increase within PAM-OFR. Temperature increases are substantially lower for OFRs utilizing less powerful lamps compared to the Aerodyne version.
- 27 August 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (16) , 4915-4939
Open AccessA comprehensive evaluation of enhanced temperature influence on gas and aerosol chemistry in the lamp-enclosed oxidation flow reactor (OFR) system
Oxidation flow reactors (OFRs) have been extensively utilized to examine the formation of secondary organic aerosol (SOA). However, the UV lamps typically employed to initiate the photochemistry in OFRs can result in an elevated reactor temperature when their implications are not thoroughly evaluated. In this study, we conducted a comprehensive investigation into the temperature distribution within an Aerodyne potential aerosol mass OFR (PAM-OFR) and then examined the subsequent effects on flow and chemistry due to lamp heating. A lamp-induced temperature increase was observed, which was a function of lamp-driving voltage, number of lamps, lamp types, OFR residence time, and positions within the PAM-OFR. Under typical PAM-OFR operational conditions (e.g., < 5 d of equivalent atmospheric OH exposure under low-NOx conditions), the temperature increase typically ranged from 1–5 °C. Under extreme (but less frequently encountered) conditions, the heating could reach up to 15 °C. The influences of the increased temperature over ambient conditions on the flow distribution, gas, and condensed-phase chemistry within PAM-OFR were evaluated. Our findings indicate that the increase in temperature altered the flow field, resulting in a diminished tail on the residence time distribution and corresponding oxidant exposure due to faster recirculation. According to simulation results from a radical chemistry box model, the variation in absolute oxidant concentration within PAM-OFR due to temperature increase was minimal (< 5 %). The temperature influences on seed organic aerosol (OA) and newly formed secondary OA were also investigated, suggesting that an increase in temperature can impact the yield, size, and oxidation levels of representative biogenic and anthropogenic SOA types. Recommendations for temperature-dependent SOA yield corrections and PAM-OFR operating protocols that mitigate lamp-induced temperature enhancement and fluctuations are presented. We recommend blowing air around the reactor's exterior with fans during PAM-OFR experiments to minimize the temperature increase within PAM-OFR. Temperature increases are substantially lower for OFRs utilizing less powerful lamps compared to the Aerodyne version.
- Open Access
- 12 March 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (5) , 1545-1559
Absorption of volatile organic compounds (VOCs) by polymer tubing: implications for indoor air and use as a simple gas-phase volatility separation technique
Previous studies have demonstrated volatility-dependent absorption of gas-phase volatile organic compounds (VOCs) to Teflon and other polymers. Polymer–VOC interactions are relevant for atmospheric chemistry sampling, as gas–wall partitioning in polymer tubing can cause delays and biases during measurements. They are also relevant to the study of indoor chemistry, where polymer-based materials are abundant (e.g., carpets and paints). In this work, we quantify the absorptive capacities of multiple tubing materials, including four nonconductive polymers (important for gas sampling and indoor air quality), four electrically conductive polymers and two commercial steel coatings (for gas and particle sampling). We compare their performance to previously characterized materials. To quantify the absorptive capacities, we expose the tubing to a series of ketones in the volatility range 104–109 µg m−3 and monitor transmission. For slow-diffusion polymers (e.g., perfluoroalkoxy alkane (PFA) Teflon and nylon), absorption is limited to a thin surface layer, and a single-layer absorption model can fit the data well. For fast-diffusion polymers (e.g., polyethylene and conductive silicone), a larger depth of the polymer is available for diffusion, and a multilayer absorption model is needed. The multilayer model allows fitting solid-phase diffusion coefficients for different materials, which range from to cm2 s−1. These diffusion coefficients are ∼ 8 orders of magnitude larger than literature values for fluorinated ethylene propylene (FEP) Teflon film. This enormous difference explains the differences in VOC absorption measured here. We fit an equivalent absorptive mass (CW, µg m−3) for each absorptive material. We found PFA to be the least absorptive, with CW ∼ 105 µg m−3, and conductive silicone to be the most absorptive, with CW ∼ 1013 µg m−3. PFA transmits VOCs easily and intermediate-volatility species (IVOCs) with quantifiable delays. In contrast, conductive silicone tubing transmits only the most volatile VOCs, denuding all lower-volatility species. Semi-volatile species (SVOCs) are very difficult to sample quantitatively through any tubing material. We demonstrate a system combining several slow- and fast-diffusion tubing materials that can be used to separate a mixture of VOCs into volatility classes. New conductive silicone tubing contaminated the gas stream with siloxanes, but this effect was reduced 10 000-fold for aged tubing, while maintaining the same absorptive properties. SilcoNert (tested in this work) and Silonite (tested in previous work) steel coatings showed gas transmission that was almost as good as PFA, but since they undergo adsorption, their delay times may be humidity- and concentration-dependent.- 12 March 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (5) , 1545-1559
Open AccessAbsorption of volatile organic compounds (VOCs) by polymer tubing: implications for indoor air and use as a simple gas-phase volatility separation technique
Previous studies have demonstrated volatility-dependent absorption of gas-phase volatile organic compounds (VOCs) to Teflon and other polymers. Polymer–VOC interactions are relevant for atmospheric chemistry sampling, as gas–wall partitioning in polymer tubing can cause delays and biases during measurements. They are also relevant to the study of indoor chemistry, where polymer-based materials are abundant (e.g., carpets and paints). In this work, we quantify the absorptive capacities of multiple tubing materials, including four nonconductive polymers (important for gas sampling and indoor air quality), four electrically conductive polymers and two commercial steel coatings (for gas and particle sampling). We compare their performance to previously characterized materials. To quantify the absorptive capacities, we expose the tubing to a series of ketones in the volatility range 104–109 µg m−3 and monitor transmission. For slow-diffusion polymers (e.g., perfluoroalkoxy alkane (PFA) Teflon and nylon), absorption is limited to a thin surface layer, and a single-layer absorption model can fit the data well. For fast-diffusion polymers (e.g., polyethylene and conductive silicone), a larger depth of the polymer is available for diffusion, and a multilayer absorption model is needed. The multilayer model allows fitting solid-phase diffusion coefficients for different materials, which range from to cm2 s−1. These diffusion coefficients are ∼ 8 orders of magnitude larger than literature values for fluorinated ethylene propylene (FEP) Teflon film. This enormous difference explains the differences in VOC absorption measured here. We fit an equivalent absorptive mass (CW, µg m−3) for each absorptive material. We found PFA to be the least absorptive, with CW ∼ 105 µg m−3, and conductive silicone to be the most absorptive, with CW ∼ 1013 µg m−3. PFA transmits VOCs easily and intermediate-volatility species (IVOCs) with quantifiable delays. In contrast, conductive silicone tubing transmits only the most volatile VOCs, denuding all lower-volatility species. Semi-volatile species (SVOCs) are very difficult to sample quantitatively through any tubing material. We demonstrate a system combining several slow- and fast-diffusion tubing materials that can be used to separate a mixture of VOCs into volatility classes. New conductive silicone tubing contaminated the gas stream with siloxanes, but this effect was reduced 10 000-fold for aged tubing, while maintaining the same absorptive properties. SilcoNert (tested in this work) and Silonite (tested in previous work) steel coatings showed gas transmission that was almost as good as PFA, but since they undergo adsorption, their delay times may be humidity- and concentration-dependent. - Open Access
- 31 January 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-23
Reply on RC2
Previous studies have demonstrated volatility-dependent absorption of gas-phase volatile organic compounds (VOCs) to Teflon and other polymers. Polymer-VOC interactions are relevant for atmospheric chemistry sampling, as gas-wall partitioning in polymer tubing can cause delays and biases during measurements. They are also relevant to the study of indoor chemistry, where polymer-based materials are abundant (e.g. carpets, paints). In this work, we quantify the absorptive capacities of multiple tubing materials, including 4 non-conductive polymers (important for gas sampling and indoor air quality), as well as 4 electrically-conductive polymers and 2 commercial steel coatings (for gas and particle sampling). We compare their performance to previously-characterized materials. To quantify the absorptive capacities, we expose the tubing to a series of ketones in the volatility range 104–109 μg m−3 and monitor transmission. For slow-diffusion polymers (e.g. PFA Teflon and nylon), absorption is limited to a thin surface layer, and a single layer absorption model can fit the data well. For fast-diffusion polymers (e.g. polyethylene and conductive silicone) a larger depth of the polymer is available for diffusion, and a multilayer absorption model was needed. The multilayer model allows fitting solid phase diffusion coefficients for different materials, which range from 4 × 10−9 to 4 × 10−7 cm2 s−1. These diffusion coefficients are ~8 orders of magnitude larger than literature values for FEP Teflon. This enormous difference explains the differences in VOC absorption measured here. We fit an equivalent absorptive mass (Cw, μg m−3) for each absorptive material. We found PFA to be the least absorptive, with Cw ~105 μg m−3, and conductive silicone to be the most absorptive, with Cw ~1013 μg m−3. PFA transmits VOCs easily, and intermediate-volatility species (IVOCs) with quantifiable delays. In contrast, conductive silicone tubing transmits only the most volatile VOCs, denuding all lower volatility species. Semi-volatile species (SVOCs) are very difficult to sample quantitatively through any tubing material. We demonstrate how to use a combination of slow- and fast-diffusion tubing to separate a mixture of VOCs into volatility classes before analysis. New conductive silicone tubing contaminated the gas stream with siloxanes, but this effect was reduced by 10,000-fold for aged tubing, while maintaining the same absorptive properties. SilcoNert (tested in this work) and Silonite (tested in previous work) steel coatings showed gas transmission that was almost as good as PFA, but since they undergo adsorption, their delays times may be humidity and concentration dependent.
- 31 January 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-23
Open AccessReply on RC2
Previous studies have demonstrated volatility-dependent absorption of gas-phase volatile organic compounds (VOCs) to Teflon and other polymers. Polymer-VOC interactions are relevant for atmospheric chemistry sampling, as gas-wall partitioning in polymer tubing can cause delays and biases during measurements. They are also relevant to the study of indoor chemistry, where polymer-based materials are abundant (e.g. carpets, paints). In this work, we quantify the absorptive capacities of multiple tubing materials, including 4 non-conductive polymers (important for gas sampling and indoor air quality), as well as 4 electrically-conductive polymers and 2 commercial steel coatings (for gas and particle sampling). We compare their performance to previously-characterized materials. To quantify the absorptive capacities, we expose the tubing to a series of ketones in the volatility range 104–109 μg m−3 and monitor transmission. For slow-diffusion polymers (e.g. PFA Teflon and nylon), absorption is limited to a thin surface layer, and a single layer absorption model can fit the data well. For fast-diffusion polymers (e.g. polyethylene and conductive silicone) a larger depth of the polymer is available for diffusion, and a multilayer absorption model was needed. The multilayer model allows fitting solid phase diffusion coefficients for different materials, which range from 4 × 10−9 to 4 × 10−7 cm2 s−1. These diffusion coefficients are ~8 orders of magnitude larger than literature values for FEP Teflon. This enormous difference explains the differences in VOC absorption measured here. We fit an equivalent absorptive mass (Cw, μg m−3) for each absorptive material. We found PFA to be the least absorptive, with Cw ~105 μg m−3, and conductive silicone to be the most absorptive, with Cw ~1013 μg m−3. PFA transmits VOCs easily, and intermediate-volatility species (IVOCs) with quantifiable delays. In contrast, conductive silicone tubing transmits only the most volatile VOCs, denuding all lower volatility species. Semi-volatile species (SVOCs) are very difficult to sample quantitatively through any tubing material. We demonstrate how to use a combination of slow- and fast-diffusion tubing to separate a mixture of VOCs into volatility classes before analysis. New conductive silicone tubing contaminated the gas stream with siloxanes, but this effect was reduced by 10,000-fold for aged tubing, while maintaining the same absorptive properties. SilcoNert (tested in this work) and Silonite (tested in previous work) steel coatings showed gas transmission that was almost as good as PFA, but since they undergo adsorption, their delays times may be humidity and concentration dependent.