Yousef Lawrence
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yousef Lawrence has a total of 149 co-authors. Here are the top co-authors by number of shared publications:
- Maria Gatu Johnson
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
17 shared publications - Johan A. Frenje
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
16 shared publications - Christopher Wink
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
14 shared publications - Skylar G. Dannhoff
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
14 shared publications - Benjamin L. Reichelt
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
13 shared publications - Timothy Mark Johnson
Lawrence Livermore National Laboratory 2 , Livermore, California 94550
12 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Evaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessEvaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Magnetic recoil neutron spectrometry for inertial confinement fusion: To ignition and beyond (invited)
For more than 15 years, the magnetic recoil spectrometer (MRS) has been used to measure the DT fusion neutron spectrum in inertial confinement fusion (ICF) implosions at OMEGA and the National Ignition Facility (NIF). These measurements have provided essential information about implosion performance that has helped guide the mainline ICF programs to the recent demonstration of hydro-equivalent ignition (χ > 1) at OMEGA and to ignition and target gain (G > 1) at the NIF. Today, there are variants of the MRS being built across private industry, including spectrometers on the SPARC tokamak (expected Q > 1, 100 MW) and the Pacific Fusion Demonstration System (expected G ∼10, 100 MJ), both with planned electronic detection systems capable of measuring neutron spectra at high processing rates. In addition, an upgrade of the existing MRS on the NIF is being planned in which a collimator will be incorporated to extend the MRS measurement ceiling to ∼30 MJ. Meanwhile, electromagnet upgrades (MRSnext) have been designed to replace, or complement, the existing MRS systems on OMEGA and the NIF. These, plus other upgrades, will result in several notable improvements from a scientific and/or engineering perspective: significantly smaller focal planes, improved resolution, conversion foils positioned close to the magnet system, and enhanced signal-to-background. Here, we summarize the MRS motivation and history, concept, demonstrated performance, and many of the recent developments, highlighting the versatility of the technique for diagnosing fusion performance across approaches on the road to high energy gain and commercialization.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessMagnetic recoil neutron spectrometry for inertial confinement fusion: To ignition and beyond (invited)
For more than 15 years, the magnetic recoil spectrometer (MRS) has been used to measure the DT fusion neutron spectrum in inertial confinement fusion (ICF) implosions at OMEGA and the National Ignition Facility (NIF). These measurements have provided essential information about implosion performance that has helped guide the mainline ICF programs to the recent demonstration of hydro-equivalent ignition (χ > 1) at OMEGA and to ignition and target gain (G > 1) at the NIF. Today, there are variants of the MRS being built across private industry, including spectrometers on the SPARC tokamak (expected Q > 1, 100 MW) and the Pacific Fusion Demonstration System (expected G ∼10, 100 MJ), both with planned electronic detection systems capable of measuring neutron spectra at high processing rates. In addition, an upgrade of the existing MRS on the NIF is being planned in which a collimator will be incorporated to extend the MRS measurement ceiling to ∼30 MJ. Meanwhile, electromagnet upgrades (MRSnext) have been designed to replace, or complement, the existing MRS systems on OMEGA and the NIF. These, plus other upgrades, will result in several notable improvements from a scientific and/or engineering perspective: significantly smaller focal planes, improved resolution, conversion foils positioned close to the magnet system, and enhanced signal-to-background. Here, we summarize the MRS motivation and history, concept, demonstrated performance, and many of the recent developments, highlighting the versatility of the technique for diagnosing fusion performance across approaches on the road to high energy gain and commercialization.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Results from the first implementation of a DT3He gas-filled thin-glass capsule backlighter for charged-particle radiography at the National Ignition Facility
A DT3He gas-filled capsule implosion-based tri-particle backlighter has been fielded on the National Ignition Facility (NIF) for the first time. This platform extends the implosion-based D3He proton backlighters developed at OMEGA and later fielded on NIF to probe high-energy-density plasmas. Its uses include charged-particle radiography for measuring electric and magnetic fields and stopping-power measurements. In addition to the 14.7 and 3.0 MeV protons produced by D3He-filled capsules, the DT3He platform produces a 9.5 MeV T3He deuteron, which is less susceptible to magnetic and electric deflection and to scattering than the 3.0 MeV DD proton, making it attractive for radiography of dense, high-field plasmas often found on NIF. During this first deployment on NIF, the measured D3He-proton yield was adequate for proton radiography, while the T3He-deuteron yield was low and will be increased in future experiments. This paper documents the implementation and performance of the DT3He backlighter platform on NIF.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Results from the first implementation of a DT3He gas-filled thin-glass capsule backlighter for charged-particle radiography at the National Ignition Facility
A DT3He gas-filled capsule implosion-based tri-particle backlighter has been fielded on the National Ignition Facility (NIF) for the first time. This platform extends the implosion-based D3He proton backlighters developed at OMEGA and later fielded on NIF to probe high-energy-density plasmas. Its uses include charged-particle radiography for measuring electric and magnetic fields and stopping-power measurements. In addition to the 14.7 and 3.0 MeV protons produced by D3He-filled capsules, the DT3He platform produces a 9.5 MeV T3He deuteron, which is less susceptible to magnetic and electric deflection and to scattering than the 3.0 MeV DD proton, making it attractive for radiography of dense, high-field plasmas often found on NIF. During this first deployment on NIF, the measured D3He-proton yield was adequate for proton radiography, while the T3He-deuteron yield was low and will be increased in future experiments. This paper documents the implementation and performance of the DT3He backlighter platform on NIF.
- Open Access
- 30 September 2026
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 92 (5) , E134
Modulated deuteron spectra observed with the magnetic recoil neutron spectrometer at the National Ignition Facility
The Magnetic Recoil Spectrometer (MRS) at the National Ignition Facility is used to measure the neutron spectrum from deuterium–tritium-fuelled inertial confinement fusion implosions via neutron–deuteron elastic scattering and magnetic dispersion of recoil deuterons. From the MRS-determined neutron spectrum, the yield ( upper Y Subscript n $Y_n$ ), apparent ion temperature ( upper T Subscript i $T_i$ ) and areal density ( rho upper R $\rho R$ ) are determined. However, anomalous energy modulations in recoil deuterons have been observed in several high-yield indirect drive experiments ( upper Y Subscript n Baseline tilde 10 Superscript 16 Baseline minus 10 Superscript 18 $Y_n\sim 10^{16}{-}10^{18}$ ). These observations raise concerns about their potential impact on the MRS-inferred performance metrics. Analytic calculations and particle-in-cell simulations are used to examine the possible beam–plasma instabilities, which indicate the two-stream instability as a plausible mechanism behind energy modulations. Based on a statistical analysis of synthetic deuteron spectra, the modulation-induced errors are found to be within the errors of the determined upper Y Subscript n $Y_n$ , upper T Subscript i $T_i$ and rho upper R $\rho R$ values and thus do not have a significant impact on the MRS measurement.- 30 September 2026
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 92 (5) , E134
Open AccessModulated deuteron spectra observed with the magnetic recoil neutron spectrometer at the National Ignition Facility
The Magnetic Recoil Spectrometer (MRS) at the National Ignition Facility is used to measure the neutron spectrum from deuterium–tritium-fuelled inertial confinement fusion implosions via neutron–deuteron elastic scattering and magnetic dispersion of recoil deuterons. From the MRS-determined neutron spectrum, the yield ( upper Y Subscript n $Y_n$ ), apparent ion temperature ( upper T Subscript i $T_i$ ) and areal density ( rho upper R $\rho R$ ) are determined. However, anomalous energy modulations in recoil deuterons have been observed in several high-yield indirect drive experiments ( upper Y Subscript n Baseline tilde 10 Superscript 16 Baseline minus 10 Superscript 18 $Y_n\sim 10^{16}{-}10^{18}$ ). These observations raise concerns about their potential impact on the MRS-inferred performance metrics. Analytic calculations and particle-in-cell simulations are used to examine the possible beam–plasma instabilities, which indicate the two-stream instability as a plausible mechanism behind energy modulations. Based on a statistical analysis of synthetic deuteron spectra, the modulation-induced errors are found to be within the errors of the determined upper Y Subscript n $Y_n$ , upper T Subscript i $T_i$ and rho upper R $\rho R$ values and thus do not have a significant impact on the MRS measurement. - 21 October 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (17) , 175102
Revealing the Structure and Dynamics of Self-Generated Electric and Magnetic Fields Near Plasma Stagnation in Laser-Driven Hohlraums
By coupling newly developed triparticle charged particle radiography with radiography reconstruction algorithms and novel reconstruction postprocessing techniques, the spatial structure and time evolution of self-generated electric and magnetic fields in laser-driven vacuum hohlraums have been quantitatively revealed. Through high-fidelity data from a series of experiments, it is shown that late in the hohlraum evolution (after the end of laser drive) these fields are strongly correlated in both space and time, providing evidence that their evolution is primarily dominated by advection with the plasma flow. At these late times, plasma flow velocities inferred from both gross radiography analysis and field reconstructions (and corroborated with Thomson scattering measurements) indicate that the plasma is approaching stagnation near the hohlraum axis. These experiments provide not only new physical insight into spontaneously generated hohlraum fields, but also provide important spatially and temporally resolved information for future benchmarking of numerical codes.
- 21 October 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (17) , 175102
Revealing the Structure and Dynamics of Self-Generated Electric and Magnetic Fields Near Plasma Stagnation in Laser-Driven Hohlraums
By coupling newly developed triparticle charged particle radiography with radiography reconstruction algorithms and novel reconstruction postprocessing techniques, the spatial structure and time evolution of self-generated electric and magnetic fields in laser-driven vacuum hohlraums have been quantitatively revealed. Through high-fidelity data from a series of experiments, it is shown that late in the hohlraum evolution (after the end of laser drive) these fields are strongly correlated in both space and time, providing evidence that their evolution is primarily dominated by advection with the plasma flow. At these late times, plasma flow velocities inferred from both gross radiography analysis and field reconstructions (and corroborated with Thomson scattering measurements) indicate that the plasma is approaching stagnation near the hohlraum axis. These experiments provide not only new physical insight into spontaneously generated hohlraum fields, but also provide important spatially and temporally resolved information for future benchmarking of numerical codes.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- Open Access
- 1 January 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (1)
Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)
The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.
- 1 January 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (1)
Open AccessUltra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)
The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.
- Open Access
- 1 November 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (11)
Transport coefficient sensitivities in a semi-analytic model for magnetized liner inertial fusion
Performance of magnetized liner inertial fusion (MagLIF) experiments is highly dependent on transport processes including magnetized heat flows and magnetic flux losses. Magnetohydrodynamic simulations used to model these experiments require a choice of model for the transport coefficients, which are the constants of proportionality relating driving terms, such as temperature gradients and currents, to the associated heat and magnetic field transport. The coefficients have been the subject of repeated recalculation using various methods throughout the years. Using a semi-analytic MagLIF model [McBride and Slutz, Phys. Plasmas 22, 052708 (2015)], we compare models for the transport coefficients provided by Braginskii [Reviews of Plasma Physics, edited by M. A. Leontovich (Consultants Bureau, New York, 1965), Vol. 1, p. 205], Epperlein and Haines [Phys. Fluids 29, 1029 (1986)], Ji and Held [Phys. Plasmas 20, 042114 (2013)], Davies et al. [Phys. Plasmas 28, 012305 (2021)], and Sadler et al. [Phys. Rev. Lett. 126, 075001 (2021)]. The choice of model modifies magnetic-flux losses caused by the Nernst thermoelectric effect and thermal conduction losses. We present simulated results from parameter scans conducted in order to compare the effects of the different models on parameters of interest in MagLIF. In some regions of parameter space, discrepancies of up to 38% are found in integrated quantities like the fusion yield. These results may serve as a guide for experimental validation of the various models, particularly as laser preheat energies and initial axial field strengths are increased on MagLIF experiments.
- 1 November 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (11)
Open AccessTransport coefficient sensitivities in a semi-analytic model for magnetized liner inertial fusion
Performance of magnetized liner inertial fusion (MagLIF) experiments is highly dependent on transport processes including magnetized heat flows and magnetic flux losses. Magnetohydrodynamic simulations used to model these experiments require a choice of model for the transport coefficients, which are the constants of proportionality relating driving terms, such as temperature gradients and currents, to the associated heat and magnetic field transport. The coefficients have been the subject of repeated recalculation using various methods throughout the years. Using a semi-analytic MagLIF model [McBride and Slutz, Phys. Plasmas 22, 052708 (2015)], we compare models for the transport coefficients provided by Braginskii [Reviews of Plasma Physics, edited by M. A. Leontovich (Consultants Bureau, New York, 1965), Vol. 1, p. 205], Epperlein and Haines [Phys. Fluids 29, 1029 (1986)], Ji and Held [Phys. Plasmas 20, 042114 (2013)], Davies et al. [Phys. Plasmas 28, 012305 (2021)], and Sadler et al. [Phys. Rev. Lett. 126, 075001 (2021)]. The choice of model modifies magnetic-flux losses caused by the Nernst thermoelectric effect and thermal conduction losses. We present simulated results from parameter scans conducted in order to compare the effects of the different models on parameters of interest in MagLIF. In some regions of parameter space, discrepancies of up to 38% are found in integrated quantities like the fusion yield. These results may serve as a guide for experimental validation of the various models, particularly as laser preheat energies and initial axial field strengths are increased on MagLIF experiments.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Errors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessErrors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.