Leyla Akh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Leyla Akh has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoyun Ding
Biomedical Engineering Program, University of Colorado, Boulder, CO 80309, USA
5 shared publications Wei Tan
Department of Mechanical Engineering University of Colorado Boulder Colorado USA
2 shared publications- Yu Gao
Paul M. Rady Department of Mechanical Engineering, University of Colorado, Boulder, CO 80309, USA
2 shared publications - Angelo D'Alessandro
University of Colorado Anschutz Medical Campus
1 shared publication - Anika C. Neu
Paul M. Rady Department of Mechanical Engineering, University of Colorado 2 , Boulder, Colorado 80309, USA
1 shared publication Apresio K. Fajrial
Department of Mechanical Engineering University of Colorado Boulder Colorado USA
1 shared publication
Latest Publications
- Open Access
- 27 October 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (21) , 5740-5752
Selective patterning of hybrid colloids via reconfigurable acoustic-dielectric field
Frequency switching reconfigures a surface acoustic wave device between acoustic and dielectric-dominated force regimes. The device enables selective patterning of mixed particle populations impossible with acoustophoresis or dielectrophoresis alone.
- 27 October 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (21) , 5740-5752
Open AccessSelective patterning of hybrid colloids via reconfigurable acoustic-dielectric field
Frequency switching reconfigures a surface acoustic wave device between acoustic and dielectric-dominated force regimes. The device enables selective patterning of mixed particle populations impossible with acoustophoresis or dielectrophoresis alone.
- Open Access
- 14 July 2026
- Published by Wiley in Advanced Science
- Vol. 13 (55) , e76561
High‐Throughput Mechanical Rupture of Nuclear Envelope and the Intracellular Dynamics of Massive Wound Repair
The dynamics of nuclear envelope rupture and wound repair are critical biological processes that play essential roles in cell homeostasis. Previous studies on nuclear envelope repair dynamics have mainly focused on small ruptures induced by low‐throughput tools such as laser ablation and atomic force microscopy. Here, a device is presented that deterministically porates the cell membrane and nuclear envelope in high throughput, with applications in single‐cell studies of wound repair dynamics and in statistical assessments of cell poration. The device consists of sharp nanostructures in arrays of microchannels, enabling precise and localized disruption at both the plasma membrane and nuclear envelope while preserving cell viability. The distribution of endosomal sorting complexes required for transport (ESCRT) proteins after mechanical disruption at both the plasma membrane and nuclear envelope highlights the cell recovery strategy for severe wounds. Interestingly, during this extreme rupture, resources seem to be allocated more toward nuclear envelope repair. High‐throughput mechanoporation on membrane systems provides a new perspective on studying complex wound repair dynamics, opening promising avenues for further research in the field of wound healing mechanisms.
- 14 July 2026
- Published by Wiley in Advanced Science
- Vol. 13 (55) , e76561
Open AccessHigh‐Throughput Mechanical Rupture of Nuclear Envelope and the Intracellular Dynamics of Massive Wound Repair
The dynamics of nuclear envelope rupture and wound repair are critical biological processes that play essential roles in cell homeostasis. Previous studies on nuclear envelope repair dynamics have mainly focused on small ruptures induced by low‐throughput tools such as laser ablation and atomic force microscopy. Here, a device is presented that deterministically porates the cell membrane and nuclear envelope in high throughput, with applications in single‐cell studies of wound repair dynamics and in statistical assessments of cell poration. The device consists of sharp nanostructures in arrays of microchannels, enabling precise and localized disruption at both the plasma membrane and nuclear envelope while preserving cell viability. The distribution of endosomal sorting complexes required for transport (ESCRT) proteins after mechanical disruption at both the plasma membrane and nuclear envelope highlights the cell recovery strategy for severe wounds. Interestingly, during this extreme rupture, resources seem to be allocated more toward nuclear envelope repair. High‐throughput mechanoporation on membrane systems provides a new perspective on studying complex wound repair dynamics, opening promising avenues for further research in the field of wound healing mechanisms.
- Open Access
- 20 February 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (9) , 2673-2683
Vector-free DNA transfection by nuclear envelope mechanoporation
A nanolancet-based microfluidic mechanoporation device can produces reliable pores on the cell membrane and nuclear envelope. The platform allows intracellular and nuclear delivery of cargo such as plasmid DNA in high throughput.
- 20 February 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (9) , 2673-2683
Open AccessVector-free DNA transfection by nuclear envelope mechanoporation
A nanolancet-based microfluidic mechanoporation device can produces reliable pores on the cell membrane and nuclear envelope. The platform allows intracellular and nuclear delivery of cargo such as plasmid DNA in high throughput.
- Open Access
- 6 November 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (1) , 40-53
Surface acoustic wave hemolysis assay for evaluating stored red blood cells
Acoustic-integrated microfluidic platform uses SAW Hemolysis Temperature to rapidly assess stored RBC quality, revealing donor-specific aging profiles linked to BMI and metabolic dysfunction.
- 6 November 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (1) , 40-53
Open AccessSurface acoustic wave hemolysis assay for evaluating stored red blood cells
Acoustic-integrated microfluidic platform uses SAW Hemolysis Temperature to rapidly assess stored RBC quality, revealing donor-specific aging profiles linked to BMI and metabolic dysfunction.
- 1 September 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (5) , 051502
Microfluidic pumps for cell sorting
Microfluidic cell sorting has shown promising advantages over traditional bulky cell sorting equipment and has demonstrated wide-reaching applications in biological research and medical diagnostics. The most important characteristics of a microfluidic cell sorter are its throughput, ease of use, and integration of peripheral equipment onto the chip itself. In this review, we discuss the six most common methods for pumping fluid samples in microfluidic cell sorting devices, present their advantages and drawbacks, and discuss notable examples of their use. Syringe pumps are the most commonly used method for fluid actuation in microfluidic devices because they are easily accessible but they are typically too bulky for portable applications, and they may produce unfavorable flow characteristics. Peristaltic pumps, both on- and off-chip, can produce reversible flow but they suffer from pulsatile flow characteristics, which may not be preferable in many scenarios. Gravity-driven pumping, and similarly hydrostatic pumping, require no energy input but generally produce low throughputs. Centrifugal flow is used to sort cells on the basis of size or density but requires a large external rotor to produce centrifugal force. Electroosmotic pumping is appealing because of its compact size but the high voltages required for fluid flow may be incompatible with live cells. Emerging methods with potential for applications in cell sorting are also discussed. In the future, microfluidic cell sorting methods will trend toward highly integrated systems with high throughputs and low sample volume requirements.
- 1 September 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (5) , 051502
Microfluidic pumps for cell sorting
Microfluidic cell sorting has shown promising advantages over traditional bulky cell sorting equipment and has demonstrated wide-reaching applications in biological research and medical diagnostics. The most important characteristics of a microfluidic cell sorter are its throughput, ease of use, and integration of peripheral equipment onto the chip itself. In this review, we discuss the six most common methods for pumping fluid samples in microfluidic cell sorting devices, present their advantages and drawbacks, and discuss notable examples of their use. Syringe pumps are the most commonly used method for fluid actuation in microfluidic devices because they are easily accessible but they are typically too bulky for portable applications, and they may produce unfavorable flow characteristics. Peristaltic pumps, both on- and off-chip, can produce reversible flow but they suffer from pulsatile flow characteristics, which may not be preferable in many scenarios. Gravity-driven pumping, and similarly hydrostatic pumping, require no energy input but generally produce low throughputs. Centrifugal flow is used to sort cells on the basis of size or density but requires a large external rotor to produce centrifugal force. Electroosmotic pumping is appealing because of its compact size but the high voltages required for fluid flow may be incompatible with live cells. Emerging methods with potential for applications in cell sorting are also discussed. In the future, microfluidic cell sorting methods will trend toward highly integrated systems with high throughputs and low sample volume requirements.