DJDiane N. Jung

Diane N. Jung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Diane N. Jung has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of a Robot-Assisted Chemical Dialysis System

    by Diane N. Jung, Caleb Escobedo, Noah Liska, Maitrey Gramopadhye, Daniel Szafir, Alessandro Roncone, Carson J. Bruns

    Scientists perform diverse manual procedures that are tedious and laborious. Such procedures are considered a bottleneck for modern experimental science, as they consume time and increase burdens in fields including material science and medicine. We employ a user-centered approach to designing a robot-assisted system for dialysis, a common multi-day purification method used in polymer and protein synthesis. Through two usability studies, we obtain participant feedback and revise design requirements to develop the final system that satisfies scientists' needs and has the potential for applications in other experimental workflows. We anticipate that integration of this system into real synthesis procedures in a chemical wet lab will decrease workload on scientists during long experimental procedures and provide an effective approach to designing more systems that have the potential to accelerate scientific discovery and liberate scientists from tedious labor.

  • Open Access

    LEGO® as a versatile platform for building reconfigurable low-cost lab equipment

    by Diane N. Jung, Kailey E. Shara, Carson J. Bruns

    Laboratory equipment is critical for automating tasks in modern scientific research, but often limited by high costs, large footprints, and sustainability concerns. Emerging strategies to provide low-cost research automation tools include microfluidic devices, open-hardware devices, 3D printing, and LEGO® products. LEGO®-based equipment may be advantageous with respect to sustainability, since their inherent modularity enables disassembly, re-purposing and re-use. To explore the feasibility and cost savings of replacing conventional lab equipment with LEGO®-based alternatives, we developed and characterized the performance of three LEGO® TechnicTM laboratory tools: a syringe pump, an orbital shaker, and a microcentrifuge. These three machines share 384 pieces in common and can be constructed in series (687 pieces, <$83 USD) or in parallel (1215 pieces, <$174 USD). As a proof of concept, calcium carbonate microparticles were synthesized and isolated using the LEGO®-based and analogous commercial equipment, yielding comparatively similar results. Moreover, the ability to program custom shake profiles for the LEGO®-based orbital shaker gave access to a wider range of particle characteristics than the commercial shaker. We propose that the high cost savings and reusability of LEGO®-based lab tools extends beyond their well-established efficacy in K-12 STEM education to an attractive resource for budget-, space- and/or sustainability-conscious laboratories.


  • Tunable liquid lens for three-photon excitation microscopy

    by Samuel D. Gilinsky, Diane N. Jung, Greg L. Futia, Mo Zohrabi, Tarah A. Welton, Omkar D. Supekar, Emily A. Gibson, Diego Restrepo, Victor M. Bright, Juliet T. Gopinath

    We demonstrate a novel electrowetting liquid combination using a room temperature ionic liquid (RTIL) and a nonpolar liquid, 1-phenyl-1-cyclohexene (PCH) suitable for focus-tunable 3-photon microscopy. We show that both liquids have over 90% transmission at 1300 nm over a 1.1 mm pathlength and an index of refraction contrast of 0.123. A lens using these liquids can be tuned from a contact angle of 133 to 48° with applied voltages of 0 and 60 V, respectively. Finally, a three-photon imaging system including an RTIL electrowetting lens was used to image a mouse brain slice. Axial scans taken with an electrowetting lens show excellent agreement with images acquired using a mechanically scanned objective.


  • Microfluidic pumps for cell sorting

    by Leyla Akh, Diane Jung, William Frantz, Corrin Bowman, Anika C. Neu, Xiaoyun Ding

    Microfluidic cell sorting has shown promising advantages over traditional bulky cell sorting equipment and has demonstrated wide-reaching applications in biological research and medical diagnostics. The most important characteristics of a microfluidic cell sorter are its throughput, ease of use, and integration of peripheral equipment onto the chip itself. In this review, we discuss the six most common methods for pumping fluid samples in microfluidic cell sorting devices, present their advantages and drawbacks, and discuss notable examples of their use. Syringe pumps are the most commonly used method for fluid actuation in microfluidic devices because they are easily accessible but they are typically too bulky for portable applications, and they may produce unfavorable flow characteristics. Peristaltic pumps, both on- and off-chip, can produce reversible flow but they suffer from pulsatile flow characteristics, which may not be preferable in many scenarios. Gravity-driven pumping, and similarly hydrostatic pumping, require no energy input but generally produce low throughputs. Centrifugal flow is used to sort cells on the basis of size or density but requires a large external rotor to produce centrifugal force. Electroosmotic pumping is appealing because of its compact size but the high voltages required for fluid flow may be incompatible with live cells. Emerging methods with potential for applications in cell sorting are also discussed. In the future, microfluidic cell sorting methods will trend toward highly integrated systems with high throughputs and low sample volume requirements.