Heba M. Emara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Heba M. Emara has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Abeer D. Algarni
Department of Information Technology, College of Computer and Information Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh, Saudi Arabia
2 shared publicationsFathi E. Abd El-Samie
Department of Information Technology, College of Computer and Information Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh, Saudi Arabia
2 shared publications- Naglaa. F. Soliman
Department of Information Technology, College of Computer and Information Sciences, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia
2 shared publications - Walid El-Shafai
Automated Systems and Computing Lab (ASCL), Computer Science Department, Prince Sultan University, Riyadh, Saudi Arabia
2 shared publications - Reem Alkanhel
Department of Information Technology, College of Computer and Information Sciences, Princess Nourah bint Abdulrahman University
1 shared publication
Latest Publications
- Open Access
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 112835-112859
Cervical Cancer Detection: A Comprehensive Evaluation of CNN Models, Vision Transformer Approaches, and Fusion Strategies
Cervical cancer, a malignant tumor arising from the cervix, poses a significant health risk to women worldwide. Early detection plays a pivotal role in improving patient outcomes by enabling timely intervention and effective treatment. This paper explores three distinct strategies for enhancing cervical cancer detection. Firstly, four convolutional neural network (CNN) models—EfficientNetB, DenseNet, Xception, and ResNet50—are evaluated across performance metrics including accuracy, recall, F1-score, and precision. Results indicate accuracy values ranging from 0.65 to 0.78, reflecting the challenges posed by low-resolution imagery. Secondly, the ViT-Cerv methodology is introduced, leveraging ViT architecture, trained from scratch on the SkipMed dataset. The ViT-Cerv model achieves an ACC of 0.94, demonstrating promise in cervical cancer classification despite the dataset’s low resolution. Finally, the HViT-Cerv hybrid model, synergizing the strengths of both CNN models and the ViT-Cerv architecture through fusion, demonstrates enhanced accuracy ranging from 0.97 to 0.99. This underscores the efficacy of the fusion approach in achieving superior classification capabilities, showcasing a notable advancement in accuracy over individual models. A comprehensive comparison with state-of-the-art models highlights the significance of the proposed approaches in cervical cancer detection, particularly in overcoming challenges posed by low-resolution datasets.
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 112835-112859
Open AccessCervical Cancer Detection: A Comprehensive Evaluation of CNN Models, Vision Transformer Approaches, and Fusion Strategies
Cervical cancer, a malignant tumor arising from the cervix, poses a significant health risk to women worldwide. Early detection plays a pivotal role in improving patient outcomes by enabling timely intervention and effective treatment. This paper explores three distinct strategies for enhancing cervical cancer detection. Firstly, four convolutional neural network (CNN) models—EfficientNetB, DenseNet, Xception, and ResNet50—are evaluated across performance metrics including accuracy, recall, F1-score, and precision. Results indicate accuracy values ranging from 0.65 to 0.78, reflecting the challenges posed by low-resolution imagery. Secondly, the ViT-Cerv methodology is introduced, leveraging ViT architecture, trained from scratch on the SkipMed dataset. The ViT-Cerv model achieves an ACC of 0.94, demonstrating promise in cervical cancer classification despite the dataset’s low resolution. Finally, the HViT-Cerv hybrid model, synergizing the strengths of both CNN models and the ViT-Cerv architecture through fusion, demonstrates enhanced accuracy ranging from 0.97 to 0.99. This underscores the efficacy of the fusion approach in achieving superior classification capabilities, showcasing a notable advancement in accuracy over individual models. A comprehensive comparison with state-of-the-art models highlights the significance of the proposed approaches in cervical cancer detection, particularly in overcoming challenges posed by low-resolution datasets.
- Open Access
- 19 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 108126-108151
A Hybrid Compressive Sensing and Classification Approach for Dynamic Storage Management of Vital Biomedical Signals
The efficient compression and classification of medical signals, particularly electroencephalography (EEG) and electrocardiography (ECG) signals in wireless body area network (WBAN) systems, are crucial for real-time monitoring and diagnosis. This paper addresses the challenges of compressive sensing and classification in WBAN systems for EEG and ECG signals. To tackle these challenges, a sequential approach is proposed. The first step involves compressing the EEG and ECG signals using the optimized Walsh-Hadamard transform (OWHT). This transform allows for efficient representation of the signals while preserving their essential characteristics. However, the presence of noise can impact the quality of the compressed signals. To mitigate this effect, the signals are subsequently recovered using the Sparse Group Lasso 1 (SPGL1) algorithm and OWHT, which take into account the noise characteristics during the recovery process. To evaluate the performance of the proposed compressive sensing algorithm, two metrics are employed: mean squared error (MSE) and maximum correntropy criterion (MCC). These metrics provide insights into the accuracy and reliability of the recovered signals at different signal-to-sample ratio (SSR) ratios. The results of the evaluation demonstrate the effectiveness of the proposed algorithm in accurately reconstructing the EEG and ECG signals while effectively managing the noise interference. Furthermore, to enhance the classification capabilities of the compressed signals, a local binary pattern (LBP) approach is applied. This technique extracts discriminative features from the compressed signals, which are then fed into a classification algorithm based on residual learning. This classification algorithm is trained from scratch and specifically designed to work with the compressed signals. The experimental results showcase the high accuracy achieved by the proposed algorithm in classifying the compressed EEG and ECG signals without the need for signal recovery. The findings of this study highlight the potential of the proposed approach in achieving efficient and accurate medical signal analysis in WBAN systems. By eliminating the computational burden of signal recovery and leveraging the advantages of compressive sensing, the proposed algorithm offers a promising solution for real-time monitoring and diagnosis, ultimately improving the overall efficiency and effectiveness of healthcare systems.
- 19 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 108126-108151
Open AccessA Hybrid Compressive Sensing and Classification Approach for Dynamic Storage Management of Vital Biomedical Signals
The efficient compression and classification of medical signals, particularly electroencephalography (EEG) and electrocardiography (ECG) signals in wireless body area network (WBAN) systems, are crucial for real-time monitoring and diagnosis. This paper addresses the challenges of compressive sensing and classification in WBAN systems for EEG and ECG signals. To tackle these challenges, a sequential approach is proposed. The first step involves compressing the EEG and ECG signals using the optimized Walsh-Hadamard transform (OWHT). This transform allows for efficient representation of the signals while preserving their essential characteristics. However, the presence of noise can impact the quality of the compressed signals. To mitigate this effect, the signals are subsequently recovered using the Sparse Group Lasso 1 (SPGL1) algorithm and OWHT, which take into account the noise characteristics during the recovery process. To evaluate the performance of the proposed compressive sensing algorithm, two metrics are employed: mean squared error (MSE) and maximum correntropy criterion (MCC). These metrics provide insights into the accuracy and reliability of the recovered signals at different signal-to-sample ratio (SSR) ratios. The results of the evaluation demonstrate the effectiveness of the proposed algorithm in accurately reconstructing the EEG and ECG signals while effectively managing the noise interference. Furthermore, to enhance the classification capabilities of the compressed signals, a local binary pattern (LBP) approach is applied. This technique extracts discriminative features from the compressed signals, which are then fed into a classification algorithm based on residual learning. This classification algorithm is trained from scratch and specifically designed to work with the compressed signals. The experimental results showcase the high accuracy achieved by the proposed algorithm in classifying the compressed EEG and ECG signals without the need for signal recovery. The findings of this study highlight the potential of the proposed approach in achieving efficient and accurate medical signal analysis in WBAN systems. By eliminating the computational burden of signal recovery and leveraging the advantages of compressive sensing, the proposed algorithm offers a promising solution for real-time monitoring and diagnosis, ultimately improving the overall efficiency and effectiveness of healthcare systems.