Cindy Schultz-Ferguson
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cindy Schultz-Ferguson has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Massey
Imaging Medical Beamline, Australian Synchrotron, Australian National Science and Technology Organisation , Clayton, Victoria , Australia
1 shared publication - An Tran-Duy
Health Economics and Simulation Modelling Unit, Melbourne School of Population and Global Health, University of Melbourne, Melbourne, Victoria, Australia
1 shared publication - Andrew J. Davidson
Anaesthesia Research, Murdoch Children’s Research Institute, Melbourne, Australia; Department of Anaesthesia and Pain Management, Royal Children’s Hospital Melbourne, Melbourne, Australia; Department of Critical Care, University of Melbourne, Melbourne, Australia
1 shared publication - Anurika Priyanjali De Silva
Centre for Epidemiology and Biostatistics, Melbourne School of Population and Global Health, The University of Melbourne, Melbourne, Australia
1 shared publication - Britta Sylvia von Ungern-Sternberg
Department of Anaesthesia and Pain Medicine Perth Children's Hospital Nedlands Western Australia Australia
1 shared publication - Cynthia Cowling
Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Science, Monash University , Clayton, Victoria , Australia
1 shared publication
Latest Publications
- 30 October 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 142 (3) , 454-464
Chewing Gum to Treat Postoperative Nausea and Vomiting in Female Patients: A Multicenter Randomized Trial
Background: Postoperative nausea and vomiting is common after general anesthesia, with consequences for patient outcomes, satisfaction with care, and healthcare costs. The aim was to compare a new treatment, chewing gum, with a widely used intravenous agent, ondansetron, to treat postoperative nausea and vomiting in female patients in the postanesthesia care unit. Methods: This study was a multicenter, randomized, controlled noninferiority trial in 17 hospitals in Australia and New Zealand. Female patients aged 12 yr or older undergoing volatile anesthetic–based general anesthesia for laparoscopic or breast surgery were enrolled. Protocolized antiemetic prophylaxis was administered. Patients who developed postoperative nausea and vomiting in the postanesthesia care unit were randomized to either 15 min of chewing gum or 4 mg intravenous ondansetron. The primary outcome was cessation of nausea, retching, or vomiting with no recurrence nor rescue medication for 2 h after administration of the randomized intervention (i.e., complete response). Results: Of 865 enrolled patients, 218 were randomized. In a per-protocol analysis, 50 of 105 (47.6%) ondansetron-treated patients compared with 31 of 103 (30.1%) chewing gum–treated patients achieved the primary outcome (absolute risk difference [95% CI], −17.3 [−30.4 to −4.3]%), not reaching the prespecified noninferiority limit. The time to complete response was longer for patients randomized to chewing gum (hazard ratio [95% CI], 0.53 [0.34 to 0.83]), and they were more likely to receive antiemetics in the 24 h after surgery (absolute risk difference [95% CI], 14.1 [1.6 to 26.5]%). Conclusions: Chewing gum cannot be recommended as an alternative to ondansetron for treatment of postoperative nausea and vomiting in female patients administered antiemetic prophylaxis.
- 30 October 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 142 (3) , 454-464
Chewing Gum to Treat Postoperative Nausea and Vomiting in Female Patients: A Multicenter Randomized Trial
Background: Postoperative nausea and vomiting is common after general anesthesia, with consequences for patient outcomes, satisfaction with care, and healthcare costs. The aim was to compare a new treatment, chewing gum, with a widely used intravenous agent, ondansetron, to treat postoperative nausea and vomiting in female patients in the postanesthesia care unit. Methods: This study was a multicenter, randomized, controlled noninferiority trial in 17 hospitals in Australia and New Zealand. Female patients aged 12 yr or older undergoing volatile anesthetic–based general anesthesia for laparoscopic or breast surgery were enrolled. Protocolized antiemetic prophylaxis was administered. Patients who developed postoperative nausea and vomiting in the postanesthesia care unit were randomized to either 15 min of chewing gum or 4 mg intravenous ondansetron. The primary outcome was cessation of nausea, retching, or vomiting with no recurrence nor rescue medication for 2 h after administration of the randomized intervention (i.e., complete response). Results: Of 865 enrolled patients, 218 were randomized. In a per-protocol analysis, 50 of 105 (47.6%) ondansetron-treated patients compared with 31 of 103 (30.1%) chewing gum–treated patients achieved the primary outcome (absolute risk difference [95% CI], −17.3 [−30.4 to −4.3]%), not reaching the prespecified noninferiority limit. The time to complete response was longer for patients randomized to chewing gum (hazard ratio [95% CI], 0.53 [0.34 to 0.83]), and they were more likely to receive antiemetics in the 24 h after surgery (absolute risk difference [95% CI], 14.1 [1.6 to 26.5]%). Conclusions: Chewing gum cannot be recommended as an alternative to ondansetron for treatment of postoperative nausea and vomiting in female patients administered antiemetic prophylaxis.
- 17 March 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1138) , 20211243
Designing a breast support device for phase contrast tomographic imaging: getting ready for a clinical trial
Objective: To design a device that can support the breast during phase-contrast tomography, and characterise its fit parameterisation and comfort rating. Methods: 27 participants were recruited to trial a system for breast support during simulated phase contrast imaging, including being positioned on a prone imaging table while wearing the device. Participants underwent a photogrammetry analysis to establish the geometric parameterisations. All participants trialled a single-cup design while 14 participants also trialled a double-cup with suction holder and all completed a series of questionnaires to understand subjective comfort. Results: Photogrammetry revealed significant positive correlations between bra cup volume and measured prone volume (p < 0.001), and between “best fit” single-cup holder volume and measured prone volume (p < 0.005). Both holders were suitable devices in terms of subjective comfort and immobilisation while stationary. However, some re-engineering to allow for quick, easy fitting in future trials where rotation through the radiation beam will occur is necessary. Light suction was well-tolerated when required. Conclusion: All participants indicated the table and breast support devices were comfortable, and they would continue in the trial. Advances in knowledge: Phase contrast tomography is an emerging breast imaging modality and clinical trials are commencing internationally. This paper describes the biomedical engineering designs, in parallel with optimal imaging, that are necessary to measure breast volume so that adequate breast support can be achieved. Breast support devices have implications for comfort, motion correction and maximising breast tissue visualisation.
- 17 March 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1138) , 20211243
Designing a breast support device for phase contrast tomographic imaging: getting ready for a clinical trial
Objective: To design a device that can support the breast during phase-contrast tomography, and characterise its fit parameterisation and comfort rating. Methods: 27 participants were recruited to trial a system for breast support during simulated phase contrast imaging, including being positioned on a prone imaging table while wearing the device. Participants underwent a photogrammetry analysis to establish the geometric parameterisations. All participants trialled a single-cup design while 14 participants also trialled a double-cup with suction holder and all completed a series of questionnaires to understand subjective comfort. Results: Photogrammetry revealed significant positive correlations between bra cup volume and measured prone volume (p < 0.001), and between “best fit” single-cup holder volume and measured prone volume (p < 0.005). Both holders were suitable devices in terms of subjective comfort and immobilisation while stationary. However, some re-engineering to allow for quick, easy fitting in future trials where rotation through the radiation beam will occur is necessary. Light suction was well-tolerated when required. Conclusion: All participants indicated the table and breast support devices were comfortable, and they would continue in the trial. Advances in knowledge: Phase contrast tomography is an emerging breast imaging modality and clinical trials are commencing internationally. This paper describes the biomedical engineering designs, in parallel with optimal imaging, that are necessary to measure breast volume so that adequate breast support can be achieved. Breast support devices have implications for comfort, motion correction and maximising breast tissue visualisation.