Danielle L. Neumann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Danielle L. Neumann has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Gavin P. Horn
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
3 shared publications - Keith Stakes
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
2 shared publications - I.-Chen Chen
Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, USA
1 shared publication - Kenneth W. Fent
National Institute for Occupational Safety and Health, Cincinnati, USA
1 shared publication - Miriam M. Calkins
National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH, United States
1 shared publication - Nicholas Dow
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
1 shared publication
Latest Publications
- Open Access
- 9 November 2026
- Published by Springer Nature in Fire Technology
- Vol. 63 (1) , 2
Potential Airborne Particulate Matter (PM) Exposures for Firefighters Working Outside Live-Fire Training Structures
- 9 November 2026
- Published by Springer Nature in Fire Technology
- Vol. 63 (1) , 2
Open AccessPotential Airborne Particulate Matter (PM) Exposures for Firefighters Working Outside Live-Fire Training Structures
- Open Access
Evaluation of Passive Silicone Samplers Compared to Active Sampling Methods for Polycyclic Aromatic Hydrocarbons During Fire Training
Firefighters are occupationally exposed to many chemicals, including polycyclic aromatic hydrocarbons (PAHs), which are formed by the incomplete combustion of organic matter during fire response and training activities. However, due to the harsh environments in which firefighters work, as well as consideration for time and physical safety while wearing bulky equipment, traditional active sampling methods may not be feasible to measure PAH exposures. Silicone passive samplers offer an alternative approach to assess exposure during fire responses and live fire training due to their heat resistance and ease of deployment in remote or time-limited environments. In this study, the primary objective was to investigate and determine the statistical strength of the relationship between active air sampling methods and passive silicone samplers for PAHs. In this study, silicone wristbands were paired with active sampling devices in a series of burn experiments to compare PAH measurements. Silicone-based measurements correlated strongly with active air samples for the dominant PAHs found, naphthalene and phenanthrene; however, detection was limited in the wristbands when air concentrations were low in active samples. In situations where PAH levels are expected to be high and the potential for contaminant loss via off-gassing is low, silicone samplers may be a useful tool for industrial hygienists to measure PAHs in fire and other emergency responses in extreme environments.
Open AccessEvaluation of Passive Silicone Samplers Compared to Active Sampling Methods for Polycyclic Aromatic Hydrocarbons During Fire Training
Firefighters are occupationally exposed to many chemicals, including polycyclic aromatic hydrocarbons (PAHs), which are formed by the incomplete combustion of organic matter during fire response and training activities. However, due to the harsh environments in which firefighters work, as well as consideration for time and physical safety while wearing bulky equipment, traditional active sampling methods may not be feasible to measure PAH exposures. Silicone passive samplers offer an alternative approach to assess exposure during fire responses and live fire training due to their heat resistance and ease of deployment in remote or time-limited environments. In this study, the primary objective was to investigate and determine the statistical strength of the relationship between active air sampling methods and passive silicone samplers for PAHs. In this study, silicone wristbands were paired with active sampling devices in a series of burn experiments to compare PAH measurements. Silicone-based measurements correlated strongly with active air samples for the dominant PAHs found, naphthalene and phenanthrene; however, detection was limited in the wristbands when air concentrations were low in active samples. In situations where PAH levels are expected to be high and the potential for contaminant loss via off-gassing is low, silicone samplers may be a useful tool for industrial hygienists to measure PAHs in fire and other emergency responses in extreme environments.
- Open Access
- 20 September 2023
- Published by Springer Nature in Fire Technology
- Vol. 60 (1) , 1-18
Pilot Study on Fire Effluent Condensate from Full Scale Residential Fires
Studies related to effluent produced by structure and vegetation fires often focus on gas phase or solid condensed phase, with limited treatment of liquid condensate generated as smoke cools to ambient. Recent post-fire human health concerns related to systemic human exposures to fire smoke and contamination of water distribution systems after wildland urban interface fires can be informed by understanding the chemical composition of liquid condensate resulting from large-scale fire experiments. In this pilot study, fire effluent (smoke) samples were continuously drawn from five different full-scale room-and-contents fire experiments, from which condensate was collected as the effluent cooled. Elevated concentrations of several volatile organic compounds (VOCs), including benzene, toluene, xylenes, styrene, naphthalene, and acetone along with several anions were detected in the acidic effluent. Many of these same VOCs have been identified in the air during firefighter safety experiments and in post-fire water distribution systems at levels that raise concern for human health. Benzene and naphthalene concentrations in the condensate were orders of magnitude above typical water quality standards and thus may directly contaminate large volumes of water. Peak benzene concentrations were similar to highest values reported from contaminated water distribution systems after wildfire events, though additional study is needed to understand the mechanisms by which this condensate may contribute to systemic contamination. Improved understanding of liquid condensate from fire effluent may be important to other areas of human and environmental health study, and some considerations are provided for future research.
- 20 September 2023
- Published by Springer Nature in Fire Technology
- Vol. 60 (1) , 1-18
Open AccessPilot Study on Fire Effluent Condensate from Full Scale Residential Fires
Studies related to effluent produced by structure and vegetation fires often focus on gas phase or solid condensed phase, with limited treatment of liquid condensate generated as smoke cools to ambient. Recent post-fire human health concerns related to systemic human exposures to fire smoke and contamination of water distribution systems after wildland urban interface fires can be informed by understanding the chemical composition of liquid condensate resulting from large-scale fire experiments. In this pilot study, fire effluent (smoke) samples were continuously drawn from five different full-scale room-and-contents fire experiments, from which condensate was collected as the effluent cooled. Elevated concentrations of several volatile organic compounds (VOCs), including benzene, toluene, xylenes, styrene, naphthalene, and acetone along with several anions were detected in the acidic effluent. Many of these same VOCs have been identified in the air during firefighter safety experiments and in post-fire water distribution systems at levels that raise concern for human health. Benzene and naphthalene concentrations in the condensate were orders of magnitude above typical water quality standards and thus may directly contaminate large volumes of water. Peak benzene concentrations were similar to highest values reported from contaminated water distribution systems after wildfire events, though additional study is needed to understand the mechanisms by which this condensate may contribute to systemic contamination. Improved understanding of liquid condensate from fire effluent may be important to other areas of human and environmental health study, and some considerations are provided for future research.