    Increasing Analytical Quality by Designing a Thin-Layer Chromatography Scanner Method for the Determination of the Radiochemical Purity of Radiopharmaceutical Sodium Iodide 131I Oral Solution

    by Miguel Vasquez-Huaman, Américo Castro-Luna, Norma Julia Ramos-Cevallos, Donald Ramos-Perfecto, Mario Alcarraz-Curi, Jacqueline Segura-Vasquez, Danny Cáceres-Antaurco

    The goal of this study was to apply the principles of analytical quality by design (AQbD) to the analytical method for determining the radiochemical purity (PQR) of the radiopharmaceutical sodium iodide 131I oral solution, utilizing thin-layer chromatography (TLC) with a radio–TLC scanner, which also enables the evaluation of product quality. For AQbD, the analytical target profile (ATP), critical quality attributes (CQA), risk management, and the method operable design region (MODR) were defined through response surface methodology to optimize the method using MINITAB® 19 software. This study encompassed the establishment of a control strategy and the validation of the method, including the assessment of selectivity, linearity, precision, robustness, detection limit, quantification limit, range, and the stability of the sample solution. Under the experimental conditions, the method parameters of the TLC scanner were experimentally demonstrated and optimized with an injection volume of 3 µL, a radioactive concentration of 10 mCi/mL, and a carrier volume of 40 µL. Statistical analysis confirmed the method’s selectivity for the 131I iodide band Rf of 0.8, a radiochemical impurity IO3− Rf of 0.6, a linearity from 6.0 to 22.0 mCi/mL, and an intermediate precision with a global relative standard deviation (RSD) of 0.624%. The method also exhibited robustness, with a global RSD of 0.101%, a detection limit of 0.09 mCi/mL, and a quantification limit of 0.53 Ci/mL, meeting the prescribed range and displaying stability over time (at 0, 2, and 20 h) with a global RSD of 0.362%, resulting in consistent outcomes. The development of a method based on AQbD facilitated the creation of a design space and an operational space, with comprehensive knowledge of the method’s characteristics and limitations. Additionally, throughout all operations, compliance with the acceptance criteria was verified. The method’s validity was confirmed under the established conditions, making it suitable for use in the manufacturing process of sodium iodide 131I and application in nuclear medicine services.


  • Open Access

    Analytical Quality by Design (AQbD) of the TLCScanner Method for the Determination of Radiochemical Purity of the Radiopharmaceutical Sodium Iodide 131I Oral Solution

    by Miguel Vasquez, Américo Castro-Luna, Norma Julia Ramos-Cevallos, Donald Ramos-Perfecto, Mario Alcarraz-Curi, Jacqueline Segura-Vasquez, Danny Cáceres-Antaurco

    The objective of the study was to apply the principles of analytical quality by design (AQbD) to the analytical method for the determination of the radiochemical purity (PQR) of the radiopharmaceutical sodium iodide 131I oral solution, by means of thin layer chromatography (TLC) with a Radio-TLC scanner, the same one that allows to evaluate the quality of the product. For the AQbD, the analytical objective profile (ATP), critical quality attributes (CQA), risk management, the method operable design region (MODR) were defined through the response surface methodology for method optimization using the MINITAB ® software, Control Strategy and the validation of the method where the parameters of selectivity, linearity, precision, robustness, detection limit, quantification limit, range and stability of the sample solution were evaluated. Under the experimental conditions, the conditions of the method were demonstrated by TLC-Scanner and optimization was carried out for an injection volume of 3 µL, radioactive concentration of 10 mCi/mL and carrier volume of 40 µL. It was statistically demonstrated that the method is selective for the 131I iodide band Rf of 0,8 and for the radiochemical impurity IO₃⁻ Rf of 0.6, linearity from 6,0 to 22.0 mCi/mL, intermediate precision with Global RSD of 0,624%, robustness with global RSD 0,101%, detection limit of 0,09 mCi/mL, quantification limit of 0.53 Ci/mL, conforming range, and stability of the sample solution evaluated over time 0, 2 and 20 hours with a global RSD of 0,362%, obtaining consistent results. The development of the method based on AQbD allowed the generation of a design space and an operational space with knowledge of all the characteristics and limitations of the method, likewise in all the operations the conformity of the tests to the acceptance criteria was verified. The validity of our method is concluded under the established conditions, suitable for use in the manufacturing process of sodium iodide 131I and application in nuclear medicine services.