Lei Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lei Pan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yuanfeng Wang
School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China
3 shared publications - Kai Li
School of Civil Engineering, Beijing Jiaotong University, Beixiaguan Street, Haidian District, Beijing 100044, China
2 shared publications - Boqun Zhang
School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China
1 shared publication - Chengcheng Shi
School of Management, Tianjin University of Commerce, Tianjin 300134, China
1 shared publication - Kun Guo
China Railway Construction Co., Ltd., Beijing 100043, China
1 shared publication - Lei Fan
School of Economics and Management & Office of International Affairs, Beijing Jiaotong University, Beijing 100044, China
1 shared publication
Latest Publications
- Open Access
Multi-Objective Optimization of Building Energy Consumption: A Case Study of Temporary Buildings on Construction Sites
Building energy consumption management significantly impacts energy efficiency, environmental effects, and economic benefits throughout a building’s life cycle. Optimizing building energy consumption has become a great challenge in the field of green buildings. This paper proposes an automated simulation method that integrates the EnergyPlus energy consumption simulation tool with Python scripting. This approach efficiently generates large volumes of energy consumption data and supports the development of machine learning surrogate models, thereby enhancing simulation efficiency and reducing computational costs. Based on this foundation, the multi-objective optimization algorithm NSGA-III is introduced to achieve a balanced optimization of three primary objectives: building energy consumption, photovoltaic electricity generation, and thermal comfort. Through a systematic analysis of a case study involving an office building and dormitory at a construction site in China, the effects of building envelope, air conditioning systems, and occupant behavior on energy consumption are examined. The optimization results indicate that energy consumption is reduced by 41% for the office building and 38% for the dormitory. Additionally, photovoltaic electricity generation increases by 176% and 169% compared to the baseline model, while thermal comfort improves by 19% and 6%, respectively. These improvements significantly enhance energy self-sufficiency and residential comfort.
Open AccessMulti-Objective Optimization of Building Energy Consumption: A Case Study of Temporary Buildings on Construction Sites
Building energy consumption management significantly impacts energy efficiency, environmental effects, and economic benefits throughout a building’s life cycle. Optimizing building energy consumption has become a great challenge in the field of green buildings. This paper proposes an automated simulation method that integrates the EnergyPlus energy consumption simulation tool with Python scripting. This approach efficiently generates large volumes of energy consumption data and supports the development of machine learning surrogate models, thereby enhancing simulation efficiency and reducing computational costs. Based on this foundation, the multi-objective optimization algorithm NSGA-III is introduced to achieve a balanced optimization of three primary objectives: building energy consumption, photovoltaic electricity generation, and thermal comfort. Through a systematic analysis of a case study involving an office building and dormitory at a construction site in China, the effects of building envelope, air conditioning systems, and occupant behavior on energy consumption are examined. The optimization results indicate that energy consumption is reduced by 41% for the office building and 38% for the dormitory. Additionally, photovoltaic electricity generation increases by 176% and 169% compared to the baseline model, while thermal comfort improves by 19% and 6%, respectively. These improvements significantly enhance energy self-sufficiency and residential comfort.
- Open Access
Variability Analysis of the Hysteretic Behavior of Fiber-Reinforced Polymer (FRP)-Confined Concrete Columns Based on a Secondary Development Model
A reasonable material hysteretic constitutive model has a significant influence on the seismic simulation results of structures. To better describe the hysteresis seismic performance of fiber-reinforced polymer (FRP)-constrained concrete, a new modified hysteresis constitutive model is proposed based on the existing model and with sufficient consideration of the drop section of the skeleton curve. The validity of the proposed model is verified by comparing with quasi-static experimental data of FRP-confined reinforced concrete (FRP-C RC) columns in the literature. Subsequently, the compressive strength of concrete is selected as a major variable, and a quasi-Monte Carlo method is utilized to generate random samples, which are substituted into the proposed modified model and some comparison models. Finally, the hysteretic behavior of FRP-C RC columns is analyzed from the perspective of the material strength variability. The results demonstrate that (1) The proposed hysteretic constitutive model is able to provide rational predictions of the hysteretic behavior of FRP-C RC columns, and the mean relative error of each specimen is less than 6%. It can be applied to carbon FRPs (CFRPs) and glass FRPs (GFRPs), as well as different cross-sectional forms such as cylindrical and square columns. (2) A large number of hysteretic behavior cases of FRP-C RC columns can be successfully analyzed from the perspective of concrete material variability combined with finite element software. The average and variation coefficient of the maximum horizontal force of FRP-C reinforced C30 concrete columns are 76.77 kN and 0.0488, respectively, while the average and variation coefficient of the maximum horizontal force of FRP-C reinforced C50 concrete columns are 91.14 kN and 0.0454, respectively. (3) The average value and variation coefficient of the maximum horizontal force and equivalent damping ratio of FRP-C RC columns are affected by the compressive strength, axial compression ratio and reinforcement ratio, which show a certain regularity.
Open AccessVariability Analysis of the Hysteretic Behavior of Fiber-Reinforced Polymer (FRP)-Confined Concrete Columns Based on a Secondary Development Model
A reasonable material hysteretic constitutive model has a significant influence on the seismic simulation results of structures. To better describe the hysteresis seismic performance of fiber-reinforced polymer (FRP)-constrained concrete, a new modified hysteresis constitutive model is proposed based on the existing model and with sufficient consideration of the drop section of the skeleton curve. The validity of the proposed model is verified by comparing with quasi-static experimental data of FRP-confined reinforced concrete (FRP-C RC) columns in the literature. Subsequently, the compressive strength of concrete is selected as a major variable, and a quasi-Monte Carlo method is utilized to generate random samples, which are substituted into the proposed modified model and some comparison models. Finally, the hysteretic behavior of FRP-C RC columns is analyzed from the perspective of the material strength variability. The results demonstrate that (1) The proposed hysteretic constitutive model is able to provide rational predictions of the hysteretic behavior of FRP-C RC columns, and the mean relative error of each specimen is less than 6%. It can be applied to carbon FRPs (CFRPs) and glass FRPs (GFRPs), as well as different cross-sectional forms such as cylindrical and square columns. (2) A large number of hysteretic behavior cases of FRP-C RC columns can be successfully analyzed from the perspective of concrete material variability combined with finite element software. The average and variation coefficient of the maximum horizontal force of FRP-C reinforced C30 concrete columns are 76.77 kN and 0.0488, respectively, while the average and variation coefficient of the maximum horizontal force of FRP-C reinforced C50 concrete columns are 91.14 kN and 0.0454, respectively. (3) The average value and variation coefficient of the maximum horizontal force and equivalent damping ratio of FRP-C RC columns are affected by the compressive strength, axial compression ratio and reinforcement ratio, which show a certain regularity.
- 4 October 2022
- Published by Springer Nature in Materials and Structures
- Vol. 55 (8) , 1-15
Random forest-based modelling of parameters of fractional derivative concrete creep model with Bayesian optimization
- 4 October 2022
- Published by Springer Nature in Materials and Structures
- Vol. 55 (8) , 1-15
Random forest-based modelling of parameters of fractional derivative concrete creep model with Bayesian optimization