SHSejin Heo

Sejin Heo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sejin Heo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Hee Yoon

    Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea

    2 shared publications
  • Taerim Kim

    Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

    2 shared publications
  • Won Chul Cha

    Department of Digital Health, Samsung Advanced Institute for Health Science & Technology, Sungkyunkwan University, Seoul, Republic of Korea

    2 shared publications
  • Gun Tak Lee

    Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea

    1 shared publication
  • Hansol Chang

    Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

    1 shared publication
  • Hye Seung Kim

    Statistics and Data Center, Research Institute for Future Medicine, Samsung Medical Center, Seoul 06351, Korea

    1 shared publication

Latest Publications

  • Open Access

    EARLY PREDICTION OF UNEXPECTED LATENT SHOCK IN THE EMERGENCY DEPARTMENT USING VITAL SIGNS

    by Hansol Chang, Weon Jung, Juhyung Ha, Jae Yong Yu, Sejin Heo, Gun Tak Lee, Jong Eun Park, Se Uk Lee, Sung Yeon Hwang, Hee Yoon, et al.

    Objective/Introduction: Sequential vital-sign information and trends in vital signs are useful for predicting changes in patient state. This study aims to predict latent shock by observing sequential changes in patient vital signs. Methods: The dataset for this retrospective study contained a total of 93,194 emergency department (ED) visits from January 1, 2016, and December 31, 2020, and Medical Information Mart for Intensive Care (MIMIC)-IV-ED data. We further divided the data into training and validation datasets by random sampling without replacement at a 7:3 ratio. We carried out external validation with MIMIC-IV-ED. Our prediction model included logistic regression (LR), random forest (RF) classifier, a multilayer perceptron (MLP), and a recurrent neural network (RNN). To analyze the model performance, we used area under the receiver operating characteristic curve (AUROC). Results: Data of 89,250 visits of patients who met prespecified criteria were used to develop a latent-shock prediction model. Data of 142,250 patient visits from MIMIC-IV-ED satisfying the same inclusion criteria were used for external validation of the prediction model. The AUROC values of prediction for latent shock were 0.822, 0.841, 0.852, and 0.830 with RNN, MLP, RF, and LR methods, respectively, at 3 h before latent shock. This is higher than the shock index or adjusted shock index. Conclusion: We developed a latent shock prediction model based on 24 h of vital-sign sequence that changed with time and predicted the results by individual.


  • Open Access

    Effectiveness of a Real-Time Ventilation Feedback Device for Guiding Adequate Minute Ventilation: A Manikin Simulation Study

    by Sejin Heo, Sun Young Yoon, Jongchul Kim, Hye Seung Kim, Kyunga Kim, Hee Yoon, Sung Yeon Hwang, Won Chul Cha, Taerim Kim

    Background and objectives: It is often challenging even for skilled rescuers to provide adequate positive pressure ventilation consistently. This study aimed to investigate the effectiveness of a newly developed real-time ventilation feedback device (RTVFD) that estimates tidal volume (TV) and ventilation interval (VI) in real time. Materials and methods: We conducted a randomised, crossover, manikin simulation study. A total of 26 medical providers were randomly assigned to the RTVFD-assisted ventilation (RAV) first group (n = 13) and the non-assisted ventilation (NV) first group (n = 13). Participants provided ventilation using adult and paediatric bag valves (BVs) for 2 min each. After a washout period, the simulation was repeated by exchanging the participants’ groups. Results: The primary outcome was optimal TV in the RAV and NV groups using adult and paediatric BVs. A secondary outcome was optimal VI in the RAV and NV groups using adult and paediatric BVs. The proportions of optimal TV values were higher for the RAVs when using both adult and paediatric BVs (adult BV: 47.29% vs. 18.46%, p < 0.001; paediatric BV: 89.51% vs. 72.66%, p < 0.001) than for the NVs. The proportions of optimal VI were significantly higher in RAVs when using both adult and paediatric BVs than that in NVs (adult BV: 95.64% vs. 50.20%, p < 0.001; paediatric BV: 95.83% vs. 57.14%, p < 0.001). Additionally, we found that with paediatric BVs, the simulation had a higher OR for both optimal TV (13.26; 95% CI, 9.96–17.65; p < 0.001) and VI (1.32; 1.08–1.62, p = 0.007), regardless of RTVFD use. Conclusion: Real-time feedback using RTVFD significantly improves the TV and VI in both adult and paediatric BVs in a manikin simulation study.