Shuangchen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuangchen Li has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Xiaowei He
Northwest University
10 shared publications - Hongbo Guo
Northwest University
8 shared publications - Jingjing Yu
Shaanxi Normal University
4 shared publications - Jintao Li
Northwest University
4 shared publications Xuelei He
Xian Key Laboratory of Radiomics and Intelligent Perception, School of Information Sciences and Technology, Northwest University, Xian, China
4 shared publicationsBeilei Wang
Xian Key Laboratory of Radiomics and Intelligent Perception, School of Information Sciences and Technology, Northwest University, Xian, China
3 shared publications
Latest Publications
- 13 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 1074-1086
Double-Branched and Multi-Magnetic Directions Feature Fusion Network (DB&MDF2-Net) for the Accurate Reconstruction of Magnetic Particle Imaging
Objective: Magnetic particle imaging (MPI) is a novel non-destructive medical imaging method that visualizes the spatial distribution of superparamagnetic iron oxide nanoparticles. However, due to the non-uniformity of the selection and drive field, the unsatisfactory of the receive coil and the different components of the magnetization signal (induced electromotive force) detected by the orthogonal coil, processing the voltage signals measured by the receiving coils in different directions without discrimination will affect the reconstruction quality. Methods: This study introduces the Double-Branched and Multi-Magnetic Directions Feature Fusion Network (DB&MDF2-Net) to address these challenges. The dual-branch(DB) strategy processes X and Y-directional magnetic field components independently, reducing information confusion. Each branch has a dual-sampling feature(DSF) layer that captures multi-scale spatial information and preserves spatial structure, enhancing the extraction of particle distribution and edge details. Additionally, a multi-head self-attention transformer(MSA-T) layer efficiently integrates features from different modules, allowing the network to learn complex inter-feature relationships. Results: The effectiveness of the DB strategy, DSF and MSA-T layers in our proposed method were validated through ablation experiments. Simulate and phantom experiments further demonstrate significant improvements in detail capture and anti-noise capability of DB&MDF2-Net without any hardware modifications, enabling more precise restoration of real particle distribution characteristics. Conclusion: These findings suggest that DB&MDF2-Net can significantly improve the imaging accuracy of MPI. Significance: This research is expected to enhance the practicality of MPI in biomedical applications and contribute to the future development of MPI technology.
- 13 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 1074-1086
Double-Branched and Multi-Magnetic Directions Feature Fusion Network (DB&MDF2-Net) for the Accurate Reconstruction of Magnetic Particle Imaging
Objective: Magnetic particle imaging (MPI) is a novel non-destructive medical imaging method that visualizes the spatial distribution of superparamagnetic iron oxide nanoparticles. However, due to the non-uniformity of the selection and drive field, the unsatisfactory of the receive coil and the different components of the magnetization signal (induced electromotive force) detected by the orthogonal coil, processing the voltage signals measured by the receiving coils in different directions without discrimination will affect the reconstruction quality. Methods: This study introduces the Double-Branched and Multi-Magnetic Directions Feature Fusion Network (DB&MDF2-Net) to address these challenges. The dual-branch(DB) strategy processes X and Y-directional magnetic field components independently, reducing information confusion. Each branch has a dual-sampling feature(DSF) layer that captures multi-scale spatial information and preserves spatial structure, enhancing the extraction of particle distribution and edge details. Additionally, a multi-head self-attention transformer(MSA-T) layer efficiently integrates features from different modules, allowing the network to learn complex inter-feature relationships. Results: The effectiveness of the DB strategy, DSF and MSA-T layers in our proposed method were validated through ablation experiments. Simulate and phantom experiments further demonstrate significant improvements in detail capture and anti-noise capability of DB&MDF2-Net without any hardware modifications, enabling more precise restoration of real particle distribution characteristics. Conclusion: These findings suggest that DB&MDF2-Net can significantly improve the imaging accuracy of MPI. Significance: This research is expected to enhance the practicality of MPI in biomedical applications and contribute to the future development of MPI technology.
- 25 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (15) , 32527-32544
PGDPNN: prior-information generation and distribution prediction neural network for fluorescence molecular tomography reconstruction
Fluorescence molecular tomography (FMT) is a promising and high sensitivity imaging modality that reconstructs the three-dimensional distribution of interior fluorescent sources. However, FMT reconstruction suffers from limited spatial resolution due to the simplifications in the forward model and the severely ill-posed nature of the inverse problem. In this study, we perform a clustering analysis using the radiomic features of the surface signal distribution. The FMT belonging to the clustering centers, along with their corresponding light source distributions, are defined as surface templates and source templates, respectively. Based on this, we propose a deep neural network—prior-information generation and distribution prediction neural network (PGDPNN)—for reconstructing the FMT source. PGDPNN consists of two key components: a spatial transformer network (STN) for prior source transformation and a V-Net for target source reconstruction. The STN estimates affine transformation parameters between the surface templates and the actual surface distribution (referred to as the target surface). These transformation parameters are then applied to the source templates to generate prior information as the light source distribution. Finally, the generated prior and the target surface are concatenated and fed into the V-Net to predict the final source distribution in FMT. Results shown in the numerical simulation experiments and in vivo experiment demonstrate that the proposed PGDPNN achieves excellent reconstruction accuracy and morphological recovery ability, with an average Dice coefficient of 0.7927 and a location error (LE) of 0.1363mm. The PGDPNN provides a novel research avenue for the rapid and accurate detection of tumors, enhancing the practicality of FMT in biomedical applications and contributing to the future development of FMT imaging technology.
- 25 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (15) , 32527-32544
PGDPNN: prior-information generation and distribution prediction neural network for fluorescence molecular tomography reconstruction
Fluorescence molecular tomography (FMT) is a promising and high sensitivity imaging modality that reconstructs the three-dimensional distribution of interior fluorescent sources. However, FMT reconstruction suffers from limited spatial resolution due to the simplifications in the forward model and the severely ill-posed nature of the inverse problem. In this study, we perform a clustering analysis using the radiomic features of the surface signal distribution. The FMT belonging to the clustering centers, along with their corresponding light source distributions, are defined as surface templates and source templates, respectively. Based on this, we propose a deep neural network—prior-information generation and distribution prediction neural network (PGDPNN)—for reconstructing the FMT source. PGDPNN consists of two key components: a spatial transformer network (STN) for prior source transformation and a V-Net for target source reconstruction. The STN estimates affine transformation parameters between the surface templates and the actual surface distribution (referred to as the target surface). These transformation parameters are then applied to the source templates to generate prior information as the light source distribution. Finally, the generated prior and the target surface are concatenated and fed into the V-Net to predict the final source distribution in FMT. Results shown in the numerical simulation experiments and in vivo experiment demonstrate that the proposed PGDPNN achieves excellent reconstruction accuracy and morphological recovery ability, with an average Dice coefficient of 0.7927 and a location error (LE) of 0.1363mm. The PGDPNN provides a novel research avenue for the rapid and accurate detection of tumors, enhancing the practicality of FMT in biomedical applications and contributing to the future development of FMT imaging technology.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. PP (25730436) , 1-13
RGMLN:Residual Graph Model Learning Network for Bioluminescence Tomography
For bioluminescence tomography reconstruction, regularization algorithms and deep learning frameworks have been widely studied and achieved impressive results. However, the parameter selection of the regularization algorithm and the poor interpretability of deep learning methods have become the key factors that affect the reconstruction results and hinder its applicability. To mitigate the effects of this problem, in this paper, we proposed a novel residual graph model learning network (RGMLN) for bioluminescence tomography reconstruction by combining the advantages of regularization method and deep learning. RGMLN is based on the inference process of the thresholding iterative shrinkage algorithm. The difference is that the penalty term of the regularization method was replaced by a learnable nonlinear mapping between the residual and source distributions to ensure the interpretability of network. Meanwhile, considering the non-Euclidean property of the finite element mesh, a graph convolution operation based on Laplacian graph theory was conducted to aggregate features of mesh nodes using the topological information of the tetrahedral mesh. Lastly, based on residual learning and auto-encoder strategies, gradient descent and prox mapping modules were designed to structure the modeldriven RGMLN method to take advantage of both the interpretability of iterative techniques and the flexibility of learning methods. Both numerical and in vivo experiments confirmed that the proposed network has excellent positioning accuracy and can be applied to different meshes and wavelengths
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. PP (25730436) , 1-13
RGMLN:Residual Graph Model Learning Network for Bioluminescence Tomography
For bioluminescence tomography reconstruction, regularization algorithms and deep learning frameworks have been widely studied and achieved impressive results. However, the parameter selection of the regularization algorithm and the poor interpretability of deep learning methods have become the key factors that affect the reconstruction results and hinder its applicability. To mitigate the effects of this problem, in this paper, we proposed a novel residual graph model learning network (RGMLN) for bioluminescence tomography reconstruction by combining the advantages of regularization method and deep learning. RGMLN is based on the inference process of the thresholding iterative shrinkage algorithm. The difference is that the penalty term of the regularization method was replaced by a learnable nonlinear mapping between the residual and source distributions to ensure the interpretability of network. Meanwhile, considering the non-Euclidean property of the finite element mesh, a graph convolution operation based on Laplacian graph theory was conducted to aggregate features of mesh nodes using the topological information of the tetrahedral mesh. Lastly, based on residual learning and auto-encoder strategies, gradient descent and prox mapping modules were designed to structure the modeldriven RGMLN method to take advantage of both the interpretability of iterative techniques and the flexibility of learning methods. Both numerical and in vivo experiments confirmed that the proposed network has excellent positioning accuracy and can be applied to different meshes and wavelengths
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Iterative Up-and-Down Sampling Network Based on Pyramid Pooling and Attention Mechanism for 3-D System Matrix Recovery in MPI
Magnetic Particle Imaging (MPI) is a promising technique for mapping magnetic nanoparticle distributions within biological tissues. The system matrix (SM)-based reconstruction is a crucial research part in MPI. However, the time-consuming nature of SM measurements often requires repetition whenever there are changes in scan parameters, particle types, or environmental conditions. In this study, we proposed an iterative up-and-down sampling network based on pyramid pooling and attention mechanism for 3d SM recovery (3d-ISPAnet) to accelerate MPI calibration. Specifically, aiming at the smaller size and higher noise level of the MPI SM relative to the natural image, we firstly introduces a pyramid pooling module to better utilize global and local contextual information. Secondly, the deep relationship between low-resolution (LR) and high-resolution (HR) image pairs is efficiently captured by the Convolutional Block Attention Module (CBAM) based iterative up-and-down sampling module. The experiments conducted on OpenMPI data demonstrate the excellent SM recovery capability of our proposed method. Average quantitative indicators of all test samples show that it has the best normalized root-mean-square error (nRMSE) and structure similarity index measure(SSIM), and the overall performance metrics of 3dISPAnet were improved by approximately 2% to 10% over other methods.We believe that this research will enhance the practicality of MPI in biomedical applications and contribute to the future advancement of MPI technology.
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Iterative Up-and-Down Sampling Network Based on Pyramid Pooling and Attention Mechanism for 3-D System Matrix Recovery in MPI
Magnetic Particle Imaging (MPI) is a promising technique for mapping magnetic nanoparticle distributions within biological tissues. The system matrix (SM)-based reconstruction is a crucial research part in MPI. However, the time-consuming nature of SM measurements often requires repetition whenever there are changes in scan parameters, particle types, or environmental conditions. In this study, we proposed an iterative up-and-down sampling network based on pyramid pooling and attention mechanism for 3d SM recovery (3d-ISPAnet) to accelerate MPI calibration. Specifically, aiming at the smaller size and higher noise level of the MPI SM relative to the natural image, we firstly introduces a pyramid pooling module to better utilize global and local contextual information. Secondly, the deep relationship between low-resolution (LR) and high-resolution (HR) image pairs is efficiently captured by the Convolutional Block Attention Module (CBAM) based iterative up-and-down sampling module. The experiments conducted on OpenMPI data demonstrate the excellent SM recovery capability of our proposed method. Average quantitative indicators of all test samples show that it has the best normalized root-mean-square error (nRMSE) and structure similarity index measure(SSIM), and the overall performance metrics of 3dISPAnet were improved by approximately 2% to 10% over other methods.We believe that this research will enhance the practicality of MPI in biomedical applications and contribute to the future advancement of MPI technology.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 65-76
CSA-FCN: Channel- and Spatial-Gated Attention Mechanism Based Fully Complex-Valued Neural Network for System Matrix Calibration in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is an emerging medical imaging technique that visualizes the spatial distribution of magnetic nanoparticles (MNPs). The system matrix (SM)- based reconstruction is enable to sensitively account for various system imperfections and offers high-fidelity volume images. Yet, the re-calibration of SMs is time-consuming when the imaging mode changes. Here, through adequately analyzing the properties of SMs, a channel- and spatial- gated attention mechanism based fully complex-valued neural network (CSA-FCN) was introduced for SM calibration in MPI. Specifically, a complex-valued constraint model for SM calibration is designed to focus on the complex-valued property of SM samples. Firstly, complex-valued convolution neural network (C-CNN) is leveraged to coarsely extract complex-valued features of the SMs. Additionally, in complex-valued domain, the channel- and spatial-based gated attention mechanisms are constructed to enhance features with lightweight advantage, named C-SEM and C-SAM respectively. C-SEM induces the network to suppress the noise expression at channel-level. C-SAM improves the network context sensitivity at spatial-level. Ultimately, aggregate the features at each level as global embedding representation, and calibrating the SM form local- to full-size through a pre-constructed consistency reconstruction layer. Analysis and experiments indicate that CSA-FCN significantly improves the efficiency of SM calibration and has excellent robustness against to different imaging modes.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 65-76
CSA-FCN: Channel- and Spatial-Gated Attention Mechanism Based Fully Complex-Valued Neural Network for System Matrix Calibration in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is an emerging medical imaging technique that visualizes the spatial distribution of magnetic nanoparticles (MNPs). The system matrix (SM)- based reconstruction is enable to sensitively account for various system imperfections and offers high-fidelity volume images. Yet, the re-calibration of SMs is time-consuming when the imaging mode changes. Here, through adequately analyzing the properties of SMs, a channel- and spatial- gated attention mechanism based fully complex-valued neural network (CSA-FCN) was introduced for SM calibration in MPI. Specifically, a complex-valued constraint model for SM calibration is designed to focus on the complex-valued property of SM samples. Firstly, complex-valued convolution neural network (C-CNN) is leveraged to coarsely extract complex-valued features of the SMs. Additionally, in complex-valued domain, the channel- and spatial-based gated attention mechanisms are constructed to enhance features with lightweight advantage, named C-SEM and C-SAM respectively. C-SEM induces the network to suppress the noise expression at channel-level. C-SAM improves the network context sensitivity at spatial-level. Ultimately, aggregate the features at each level as global embedding representation, and calibrating the SM form local- to full-size through a pre-constructed consistency reconstruction layer. Analysis and experiments indicate that CSA-FCN significantly improves the efficiency of SM calibration and has excellent robustness against to different imaging modes.
- 21 February 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (5) , 1161-1164
FSMN-Net: a free space matching network based on manifold convolution for optical molecular tomography
Optical molecular tomography (OMT) can monitor glioblastomas in small animals non-invasively. Although deep learning (DL) methods have made remarkable achievements in this field, improving its generalization against diverse reconstruction systems remains a formidable challenge. In this Letter, a free space matching network (FSMN-Net) was presented to overcome the parameter mismatch problem in different reconstruction systems. Specifically, a novel, to the best of our knowledge, manifold convolution operator was designed by considering the mathematical model of OMT as a space matching process. Based on the dynamic domain expansion concept, an end-to-end fully convolutional codec further integrates this operator to realize robust reconstruction with voxel-level accuracy. The results of numerical simulations and in vivo experiments demonstrate that the FSMN-Net can stably generate high-resolution reconstruction volumetric images under different reconstruction systems.
- 21 February 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (5) , 1161-1164
FSMN-Net: a free space matching network based on manifold convolution for optical molecular tomography
Optical molecular tomography (OMT) can monitor glioblastomas in small animals non-invasively. Although deep learning (DL) methods have made remarkable achievements in this field, improving its generalization against diverse reconstruction systems remains a formidable challenge. In this Letter, a free space matching network (FSMN-Net) was presented to overcome the parameter mismatch problem in different reconstruction systems. Specifically, a novel, to the best of our knowledge, manifold convolution operator was designed by considering the mathematical model of OMT as a space matching process. Based on the dynamic domain expansion concept, an end-to-end fully convolutional codec further integrates this operator to realize robust reconstruction with voxel-level accuracy. The results of numerical simulations and in vivo experiments demonstrate that the FSMN-Net can stably generate high-resolution reconstruction volumetric images under different reconstruction systems.
- 19 September 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (10) , 5298-5315
Liver injury monitoring using dynamic fluorescence molecular tomography based on a time-energy difference strategy
Dynamic fluorescence molecular tomography (DFMT) is a promising molecular imaging technique that offers the potential to monitor fast kinetic behaviors within small animals in three dimensions. Early monitoring of liver disease requires the ability to distinguish and analyze normal and injured liver tissues. However, the inherent ill-posed nature of the problem and energy signal interference between the normal and injured liver regions limit the practical application of liver injury monitoring. In this study, we propose a novel strategy based on time and energy, leveraging the temporal correlation in fluorescence molecular imaging (FMI) sequences and the metabolic differences between normal and injured liver tissue. Additionally, considering fluorescence signal distribution disparity between the injured and normal regions, we designed a universal Golden Ratio Primal-Dual Algorithm (GRPDA) to reconstruct both the normal and injured liver regions. Numerical simulation and in vivo experiment results demonstrate that the proposed strategy can effectively avoid signal interference between liver and liver injury energy and lead to significant improvements in morphology recovery and positioning accuracy compared to existing approaches. Our research presents a new perspective on distinguishing normal and injured liver tissues for early liver injury monitoring.
- 19 September 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (10) , 5298-5315
Liver injury monitoring using dynamic fluorescence molecular tomography based on a time-energy difference strategy
Dynamic fluorescence molecular tomography (DFMT) is a promising molecular imaging technique that offers the potential to monitor fast kinetic behaviors within small animals in three dimensions. Early monitoring of liver disease requires the ability to distinguish and analyze normal and injured liver tissues. However, the inherent ill-posed nature of the problem and energy signal interference between the normal and injured liver regions limit the practical application of liver injury monitoring. In this study, we propose a novel strategy based on time and energy, leveraging the temporal correlation in fluorescence molecular imaging (FMI) sequences and the metabolic differences between normal and injured liver tissue. Additionally, considering fluorescence signal distribution disparity between the injured and normal regions, we designed a universal Golden Ratio Primal-Dual Algorithm (GRPDA) to reconstruct both the normal and injured liver regions. Numerical simulation and in vivo experiment results demonstrate that the proposed strategy can effectively avoid signal interference between liver and liver injury energy and lead to significant improvements in morphology recovery and positioning accuracy compared to existing approaches. Our research presents a new perspective on distinguishing normal and injured liver tissues for early liver injury monitoring.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 898-903
Based on model-driven fast iterative shrinkage thresholding network for bioluminescence tomography reconstruction
Bioluminescence tomography (BLT) is an effective noninvasive molecular imaging modality, it has shown great potential for studying and monitoring disease progression in pre-clinical imaging. As the BLT is an inherent highly ill-posed inverse problem, it is still a challenge to obtain an accurate reconstruction result. Some algorithms have been proposed to solve highly ill posedness of inverse problems. Nevertheless, Existing methods always need to consume large time or have low interpretability. Thus, in this paper, we proposed a novel model-driven deep learning network, which unfolding the Fast Iterative Shrinkage Thresholding Algorithm (FISTA) algorithm into a deep network, named FISTA-Net to overcome the above shortcoming. FISTA-Net is formed from three modules, gradient descent module, proximal mapping module and accelerate module. Key parameters of FISTA-Net including the gradient step size, thresholding value are learned from training data. The experimental results, evaluated both visually and quantitatively, show that the FISTA-Net can achieve a high-quality reconstruction result of BLT.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 898-903
Based on model-driven fast iterative shrinkage thresholding network for bioluminescence tomography reconstruction
Bioluminescence tomography (BLT) is an effective noninvasive molecular imaging modality, it has shown great potential for studying and monitoring disease progression in pre-clinical imaging. As the BLT is an inherent highly ill-posed inverse problem, it is still a challenge to obtain an accurate reconstruction result. Some algorithms have been proposed to solve highly ill posedness of inverse problems. Nevertheless, Existing methods always need to consume large time or have low interpretability. Thus, in this paper, we proposed a novel model-driven deep learning network, which unfolding the Fast Iterative Shrinkage Thresholding Algorithm (FISTA) algorithm into a deep network, named FISTA-Net to overcome the above shortcoming. FISTA-Net is formed from three modules, gradient descent module, proximal mapping module and accelerate module. Key parameters of FISTA-Net including the gradient step size, thresholding value are learned from training data. The experimental results, evaluated both visually and quantitatively, show that the FISTA-Net can achieve a high-quality reconstruction result of BLT.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 78-875
Multi-target reconstruction of fluorescence molecular tomography based on blind source separation
Fluorescence molecular tomography (FMT) is an important molecular imaging technique for tumor detection in early stage. In realistic research, due to the spread and metastasis of tumor cells, it is necessary to comprehensively analyze multiple tumor regions for cancer staging studies. Therefore, high-precision multi-light source reconstruction results are required for quantitative analysis in FMT research. However, the existing methods perform well in the reconstruction of single fluorescent source but may fail in reconstructing multiple targets, which is an obstacle for FMT practical application. In this paper, we proposed a multi-target reconstruction strategy for Fluorescence Molecular Tomography based on Blind Source Separation (BSS) by converting multi-target reconstructions into multiple single-target reconstructions. It is a breakthrough work in multi-target reconstruction for cancer staging using optical molecular technique. Numerical simulation experiments proved that it had the ability of multi-source resolution for FMT in accurate location and morphology recovery. The encouraging results demonstrate significant effectiveness and potential of our method for preclinical FMT applications.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 78-875
Multi-target reconstruction of fluorescence molecular tomography based on blind source separation
Fluorescence molecular tomography (FMT) is an important molecular imaging technique for tumor detection in early stage. In realistic research, due to the spread and metastasis of tumor cells, it is necessary to comprehensively analyze multiple tumor regions for cancer staging studies. Therefore, high-precision multi-light source reconstruction results are required for quantitative analysis in FMT research. However, the existing methods perform well in the reconstruction of single fluorescent source but may fail in reconstructing multiple targets, which is an obstacle for FMT practical application. In this paper, we proposed a multi-target reconstruction strategy for Fluorescence Molecular Tomography based on Blind Source Separation (BSS) by converting multi-target reconstructions into multiple single-target reconstructions. It is a breakthrough work in multi-target reconstruction for cancer staging using optical molecular technique. Numerical simulation experiments proved that it had the ability of multi-source resolution for FMT in accurate location and morphology recovery. The encouraging results demonstrate significant effectiveness and potential of our method for preclinical FMT applications.