    Thermal Comfort Assessment of Water-based Thermal Energy Storage Integrated Heat Pump System in Cooling Operation

    by Zayed Mostafa, Khaled I. Alghamdi, Jeffrey D. Spitler, Christian K. Bach

    Water-based thermal energy storage (WTES) can be used to shift peak heating and cooling loads in residential buildings and adapt to electrical grid conditions in order to accommodate more renewable energy into the grid. This study examines the performance of a heat pump in cooling mode when integrated with a WTES using TriCoilTM, a novel three-fluid fin and tube heat exchanger, as indoor coil. This manuscript focuses on evaluating the system's effectiveness in maintaining thermal comfort in the conditioned space during discharging the WTES. The system is operated using a supervisory control model with predetermined hours for charging and discharging the WTES. We used a simplified building model that, coupled to the system model, predicts zone temperature and humidity. We conducted simulations of typical peak summer days and whole summer season in two locations of the US- Stillwater, Oklahoma and Phoenix, Arizona. The thermal comfort in the conditioned space is quantified using the predicted mean vote (PMV) for a thermostat setpoint of 23 °C. In both locations, the PMV stays within the neutral comfortable range of 0.5 to -0.5 throughout the cooling season with humidity generally maintained below 60% relative humidity. We also assessed the system's potential for reducing electricity costs through load shifting, by charging the WTES during off-peak hours for use in on-peak hours. The reduction in total electricity cost in Stillwater between June 12th and September 22nd was 11% for 75% of the on-peak hour load shifted to off-peak hours. In Phoenix, the WTES was able to shift 80% of the peak hour load and reduce total electricity cost by 16.1% between June 1st and September 30th. Finally, we investigated the impact of the maximum WTES discharge temperature on space humidity, thermal comfort and system operation by varying the temperature between 13 °C and 16 °C.

  • Effect of inlet duct design on fan performance and static pressure measurements of indoor air handling units (ASHRAE RP-1743)

    by Khaled I. Alghamdi, Christian K. Bach

    Increasing energy efficiency requirements lead to substantial increases in residential air handler unit’s length, in turn preventing usage of requiring inlet ductwork for rating tests due to testing facilities space constraints. Therefore, the main goal of ASHRAE Research Project 1743 was to investigate reduced-length alternative inlet duct configurations as compared to ASHRAE Standard inlet duct in terms of fan performance. Additionally, the project investigated other effects that might affect the repeatability of equipment testing. The investigated effects were hysteresis effect associating with adjusting external static pressure through unit under test, atmospheric pressure effect associating with daily fluctuations of atmospheric pressure in a location, side flow effect from a destratification fan in the testing facility, and floor distance effect on ASHRAE Standard 37 inlet duct. The reduced-length alternative inlet duct configurations considered were 4-inch inlet duct, inlet box with and without guide vanes, and nonconventional reduced alternative inlet duct. The alternative inlet duct configurations maintained fan performance within ±5% for fan power and ±2.5% for air volumetric flowrate except for the inlet box without guide vanes. The reduction in length relative to the standard inlet duct was between 38% and 44% for the inlet box configuration up to 71% and 73% for the reduced alternative inlet duct configuration. The hysteresis effect was significant for the push-through electronically-commutated-motor fan unit and was noticeable for the pull-through constant-torque-motor fan unit at a low air flowrate. Atmospheric pressure affected only the electronically-commutated-motor fan units significantly. Side flow from external ‘destratification’-fans had a significant effect on the push-through units in some of the configurations. Floor distance had an insignificant effect on fan performance during testing the standard inlet duct.

  • Open Access

    Impact of Implementing a Dedicated Outdoor Air System in Parallel with a Multi-Zone Variable-Air Volume System on Energy Consumption, Thermal Comfort, and Life Cycle Cost

    by Khaled Alghamdi

    Heating, Ventilating, and Air-Conditioning systems (HVAC) consume more than 40% of energy in commercial buildings, according to the Commercial Building Energy Consumption Survey in 2012. Therefore, efforts to reduce HVAC energy consumption would be significant in coping with energy-related issues. In that context and in order to enhance the indoor air quality without compromising for energy consumption, the concept of Dedicated Outdoor Air systems (DOAS) emerged. The literature shows that the integration of DOAS with other HVAC systems has been studied widely, yet the impact of integrating DOAS in parallel with multi-zone Variable-Air Volume systems (multi-zone VAV) for an application requiring high ventilation air has not been researched. Therefore, the objective of this study was to assess the impact of the integration from various aspects. For assessing the impact of implementing DOAS in parallel with multi-zone VAV, a primary school model was simulated in 17 climate zones and in 6 HVAC configurations. The simulations were conducted for conditions of 8,760 hours/year, and their results were compared to the results of a baseline model utilizing multi-zone VAV for handling the ventilation load besides handling the thermal local loads. The assessment considered the impact on energy consumption, thermal comfort, and life cycle cost. The results showed a saving in HVAC energy in all considered climate zones when the DOAS supplied ventilation air at 12.8-15.6o C Dry Bulb Temperature (DBT) and 12.8o C Dew Point Temperature (DPT). The saving in energy ranged from 4% to 40%. In addition, the climate zones with low outdoor latent loads experienced high changes in energy consumption compared to the climate zones with high outdoor latent loads. In terms of the change in thermal comfort, the Fanger Comfort Model was utilized to observe the change from the occupant perspectives. The change among the various configurations did not show a significant difference; the maximum percentage of occupants who would have experienced a difference in the thermal comfort was less than 0.5% in all climate zones. Economically, the energy cost would decrease in a configuration supplying ventilation air through DOAS with conditions of 12.8-15.6o C DBT and 12.8o C DPT in all considered climate zones. In this study, the saving in energy cost ranged from $ 500/year to $ 6,000/year. Moreover, multi-zone VAV units could be downsized significantly. However, the saving would not have been encouraging economically when it was considered for overcoming the cost of implementing DOAS; the payback