Filip Gasparic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Filip Gasparic has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Nikola Jorgovanović
Faculty of Technical Sciences, University of Novi Sad, 21000 Novi Sad, Serbia
5 shared publications - Strahinja Dosen
Aalborg University
5 shared publications - Christian Hofer
Department of Global Research, Otto Bock Healthcare Products GmbH, Vienna, Austria
3 shared publications - Darko Stanisic
Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia
3 shared publications - Mario Koppe
Department of Global Research, Ottobock SE Co. KGaA, Duderstadt, Germany
3 shared publications - Andrea Vaštag
University of Novi Sad
1 shared publication
Latest Publications
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Time-of-Flight Sensing for the Recognition of Object Properties in Prosthesis Control
Myoelectric control of hand prostheses requires users to learn unnatural command sequences, which can be both physically and mentally demanding. Semi-autonomous control seeks to automate some of them by anticipating the user's intentions, but it often relies on large, data-heavy computer vision systems that limit real-time use. Our approach applies basic geometric processing to depth data gathered by Time-of-Flight (TOF) sensors to extract object dimensions and orientation. We compared VL53L5CX and VL53L7CX sensors in different setups at various distances from the target. The narrow setup with VL53L5CX (45 mm between sensors) estimated the primary dimension (width/height) and orientation with 15 mm average error and a 66.6 % success rate. VL53L7CX performed better in orientation recognition but showed larger dimension errors and variance. Compact TOF sensor layouts, especially with different fields of view, proved effective for sparse point cloud-based recognition of object properties.
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Time-of-Flight Sensing for the Recognition of Object Properties in Prosthesis Control
Myoelectric control of hand prostheses requires users to learn unnatural command sequences, which can be both physically and mentally demanding. Semi-autonomous control seeks to automate some of them by anticipating the user's intentions, but it often relies on large, data-heavy computer vision systems that limit real-time use. Our approach applies basic geometric processing to depth data gathered by Time-of-Flight (TOF) sensors to extract object dimensions and orientation. We compared VL53L5CX and VL53L7CX sensors in different setups at various distances from the target. The narrow setup with VL53L5CX (45 mm between sensors) estimated the primary dimension (width/height) and orientation with 15 mm average error and a 66.6 % success rate. VL53L7CX performed better in orientation recognition but showed larger dimension errors and variance. Compact TOF sensor layouts, especially with different fields of view, proved effective for sparse point cloud-based recognition of object properties.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (2) , 746-756
FEEBY: A Flexible Framework for Fast Prototyping and Assessment of Vibrotactile Feedback for Hand Prostheses
Enhancing a myoelectric prosthesis with artificial somatosensory feedback is important for providing a complete bionic replacement. The development of feedback comprises several steps, from the selection of stimulation interface, variables, and encoding schemes to testing in non-disabled and amputee subjects. In most cases, specific configurations are implemented and tested. To support a more flexible approach to the development of feedback, where an interface can be iteratively tested and gradually refined, we developed FEEBY - a software and hardware framework for fast prototyping and assessment of feedback both in and out of the lab. FEEBY comprises a PC application for feedback design and subject training, an embedded system for clinical testing, and a smaller version of the system for home use. The system capabilities and the feedback design process were demonstrated by conducting illustrative experiments on 6 non-disabled participants and 1 transradial amputee, who also used the system at home. The results of the present study demonstrated that FEEBY is a compact, low-power, and robust system that can enable the systematic development of feedback and its assessment in ecological conditions. The latter aspect is particularly important to reach the ultimate goal, i.e., a feedback system that matters in daily life.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (2) , 746-756
FEEBY: A Flexible Framework for Fast Prototyping and Assessment of Vibrotactile Feedback for Hand Prostheses
Enhancing a myoelectric prosthesis with artificial somatosensory feedback is important for providing a complete bionic replacement. The development of feedback comprises several steps, from the selection of stimulation interface, variables, and encoding schemes to testing in non-disabled and amputee subjects. In most cases, specific configurations are implemented and tested. To support a more flexible approach to the development of feedback, where an interface can be iteratively tested and gradually refined, we developed FEEBY - a software and hardware framework for fast prototyping and assessment of feedback both in and out of the lab. FEEBY comprises a PC application for feedback design and subject training, an embedded system for clinical testing, and a smaller version of the system for home use. The system capabilities and the feedback design process were demonstrated by conducting illustrative experiments on 6 non-disabled participants and 1 transradial amputee, who also used the system at home. The results of the present study demonstrated that FEEBY is a compact, low-power, and robust system that can enable the systematic development of feedback and its assessment in ecological conditions. The latter aspect is particularly important to reach the ultimate goal, i.e., a feedback system that matters in daily life.
- Open Access
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 4492-4503
A Novel Sensory Feedback Approach to Facilitate Both Predictive and Corrective Control of Grasping Force in Myoelectric Prostheses
Reliable force control is especially important when using myoelectric upper-limb prostheses as the force defines whether an object will be firmly grasped, damaged, or dropped. It is known from human motor control that the grasping of able-bodied subjects is based on a combination of anticipation and feedback correction. Inspired by this insight, the present study proposes a novel approach to provide artificial sensory feedback to the user of a myoelectric prosthesis using vibrotactile stimulation to facilitate both predictive and corrective processes characteristic of grasping in able-bodied people. Specifically, the level of EMG was conveyed to the subjects while closing the prosthesis (predictive strategy), whereas the actual grasping force was transmitted when the prosthesis closed (corrective strategy). To investigate if this combined EMG and force feedback is indeed an effective method to explicitly close the control loop, 16 able-bodied and 3 transradial amputee subjects performed a set of functional tasks, inspired by the “Box and Block” test, with six target force levels, in three conditions: no feedback, only EMG feedback, and combined feedback. The highest overall performance in able-bodied subjects was obtained with combined feedback (79.6±9.9%), whereas the lowest was achieved with no feedback (53±11.5%). The combined feedback, however, increased the task completion time compared to the other two conditions. A similar trend was obtained also in three amputee subjects. The results, therefore, indicate that the feedback inspired by human motor control is indeed an effective approach to improve prosthesis grasping in realistic conditions when other sources of feedback (vision and audition) are not blocked.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 4492-4503
Open AccessA Novel Sensory Feedback Approach to Facilitate Both Predictive and Corrective Control of Grasping Force in Myoelectric Prostheses
Reliable force control is especially important when using myoelectric upper-limb prostheses as the force defines whether an object will be firmly grasped, damaged, or dropped. It is known from human motor control that the grasping of able-bodied subjects is based on a combination of anticipation and feedback correction. Inspired by this insight, the present study proposes a novel approach to provide artificial sensory feedback to the user of a myoelectric prosthesis using vibrotactile stimulation to facilitate both predictive and corrective processes characteristic of grasping in able-bodied people. Specifically, the level of EMG was conveyed to the subjects while closing the prosthesis (predictive strategy), whereas the actual grasping force was transmitted when the prosthesis closed (corrective strategy). To investigate if this combined EMG and force feedback is indeed an effective method to explicitly close the control loop, 16 able-bodied and 3 transradial amputee subjects performed a set of functional tasks, inspired by the “Box and Block” test, with six target force levels, in three conditions: no feedback, only EMG feedback, and combined feedback. The highest overall performance in able-bodied subjects was obtained with combined feedback (79.6±9.9%), whereas the lowest was achieved with no feedback (53±11.5%). The combined feedback, however, increased the task completion time compared to the other two conditions. A similar trend was obtained also in three amputee subjects. The results, therefore, indicate that the feedback inspired by human motor control is indeed an effective approach to improve prosthesis grasping in realistic conditions when other sources of feedback (vision and audition) are not blocked.
- 12 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 16 (3) , 379-390
Nonlinear Mapping From EMG to Prosthesis Closing Velocity Improves Force Control With EMG Biofeedback
When using EMG biofeedback to control the grasping force of a myoelectric prosthesis, subjects need to activate their muscles and maintain the myoelectric signal within an appropriate interval. However, their performance decreases for higher forces, because the myoelectric signal is more variable for stronger contractions. Therefore, the present study proposes to implement EMG biofeedback using nonlinear mapping, in which EMG intervals of increasing size are mapped to equal-sized intervals of the prosthesis velocity. To validate this approach, 20 able-bodied subjects performed force-matching tasks using Michelangelo prosthesis with and without EMG biofeedback with linear and nonlinear mapping. Additionally, four transradial amputees performed a functional task in the same feedback and mapping conditions. The success rate in producing desired force was significantly higher with feedback (65.4±15.9%) compared to no feedback (46.2±14.9%) as well as when using nonlinear (62.4±16.8%) versus linear mapping (49.2±17.2%). Overall, in able-bodied subjects, the highest success rate was obtained when EMG biofeedback was combined with nonlinear mapping (72%), and the opposite for linear mapping with no feedback (39.6%). The same trend was registered also in four amputee subjects. Therefore, EMG biofeedback improved prosthesis force control, especially when combined with nonlinear mapping, which showed to be an effective approach to counteract increasing variability of myoelectric signal for stronger contractions.
- 12 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 16 (3) , 379-390
Nonlinear Mapping From EMG to Prosthesis Closing Velocity Improves Force Control With EMG Biofeedback
When using EMG biofeedback to control the grasping force of a myoelectric prosthesis, subjects need to activate their muscles and maintain the myoelectric signal within an appropriate interval. However, their performance decreases for higher forces, because the myoelectric signal is more variable for stronger contractions. Therefore, the present study proposes to implement EMG biofeedback using nonlinear mapping, in which EMG intervals of increasing size are mapped to equal-sized intervals of the prosthesis velocity. To validate this approach, 20 able-bodied subjects performed force-matching tasks using Michelangelo prosthesis with and without EMG biofeedback with linear and nonlinear mapping. Additionally, four transradial amputees performed a functional task in the same feedback and mapping conditions. The success rate in producing desired force was significantly higher with feedback (65.4±15.9%) compared to no feedback (46.2±14.9%) as well as when using nonlinear (62.4±16.8%) versus linear mapping (49.2±17.2%). Overall, in able-bodied subjects, the highest success rate was obtained when EMG biofeedback was combined with nonlinear mapping (72%), and the opposite for linear mapping with no feedback (39.6%). The same trend was registered also in four amputee subjects. Therefore, EMG biofeedback improved prosthesis force control, especially when combined with nonlinear mapping, which showed to be an effective approach to counteract increasing variability of myoelectric signal for stronger contractions.