Linfang Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Linfang Xiao has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ed Xuekui Wu
The University of Hong Kong
4 shared publications - Yujiao Zhao
The University of Hong Kong
4 shared publications - Alex T. L. Leong
Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong
3 shared publications - Christopher Man
The University of Hong Kong
3 shared publications - Vick Lau
Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Pokfulam, Hong Kong SAR, China
3 shared publications - Jiahao Hu
Laboratory of Biomedical Imaging and Signal Processing The University of Hong Kong Hong Kong People's Republic of China
2 shared publications
Latest Publications
- Top Cited Papers
- 10 May 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 384 (6696) , eadm7168
Whole-body magnetic resonance imaging at 0.05 Tesla
Despite a half-century of advancements, global magnetic resonance imaging (MRI) accessibility remains limited and uneven, hindering its full potential in health care. Initially, MRI development focused on low fields around 0.05 Tesla, but progress halted after the introduction of the 1.5 Tesla whole-body superconducting scanner in 1983. Using a permanent 0.05 Tesla magnet and deep learning for electromagnetic interference elimination, we developed a whole-body scanner that operates using a standard wall power outlet and without radiofrequency and magnetic shielding. We demonstrated its wide-ranging applicability for imaging various anatomical structures. Furthermore, we developed three-dimensional deep learning reconstruction to boost image quality by harnessing extensive high-field MRI data. These advances pave the way for affordable deep learning–powered ultra-low-field MRI scanners, addressing unmet clinical needs in diverse health care settings worldwide.
- 10 May 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 384 (6696) , eadm7168
Top Cited PapersWhole-body magnetic resonance imaging at 0.05 Tesla
Despite a half-century of advancements, global magnetic resonance imaging (MRI) accessibility remains limited and uneven, hindering its full potential in health care. Initially, MRI development focused on low fields around 0.05 Tesla, but progress halted after the introduction of the 1.5 Tesla whole-body superconducting scanner in 1983. Using a permanent 0.05 Tesla magnet and deep learning for electromagnetic interference elimination, we developed a whole-body scanner that operates using a standard wall power outlet and without radiofrequency and magnetic shielding. We demonstrated its wide-ranging applicability for imaging various anatomical structures. Furthermore, we developed three-dimensional deep learning reconstruction to boost image quality by harnessing extensive high-field MRI data. These advances pave the way for affordable deep learning–powered ultra-low-field MRI scanners, addressing unmet clinical needs in diverse health care settings worldwide.
- Open Access
- 20 February 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 112-127
Robust EMI elimination for RF shielding‐free MRI through deep learning direct MR signal prediction
Purpose: To develop a new electromagnetic interference (EMI) elimination strategy for RF shielding‐free MRI via active EMI sensing and deep learning direct MR signal prediction (Deep‐DSP).Methods: Deep‐DSP is proposed to directly predict EMI‐free MR signals. During scanning, MRI receive coil and EMI sensing coils simultaneously sample data within two windows (i.e., for MR data and EMI characterization data acquisition, respectively). Afterward, a residual U‐Net model is trained using synthetic MRI receive coil data and EMI sensing coil data acquired during EMI signal characterization window, to predict EMI‐free MR signals from signals acquired by MRI receive and EMI sensing coils. The trained model is then used to directly predict EMI‐free MR signals from data acquired by MRI receive and sensing coils during the MR signal‐acquisition window. This strategy was evaluated on an ultralow‐field 0.055T brain MRI scanner without any RF shielding and a 1.5T whole‐body scanner with incomplete RF shielding.Results: Deep‐DSP accurately predicted EMI‐free MR signals in presence of strong EMI. It outperformed recently developed EDITER and convolutional neural network methods, yielding better EMI elimination and enabling use of few EMI sensing coils. Furthermore, it could work well without dedicated EMI characterization data.Conclusion: Deep‐DSP presents an effective EMI elimination strategy that outperforms existing methods, advancing toward truly portable and patient‐friendly MRI. It exploits electromagnetic coupling between MRI receive and EMI sensing coils as well as typical MR signal characteristics. Despite its deep learning nature, Deep‐DSP framework is computationally simple and efficient.
- 20 February 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 112-127
Open AccessRobust EMI elimination for RF shielding‐free MRI through deep learning direct MR signal prediction
Purpose: To develop a new electromagnetic interference (EMI) elimination strategy for RF shielding‐free MRI via active EMI sensing and deep learning direct MR signal prediction (Deep‐DSP).Methods: Deep‐DSP is proposed to directly predict EMI‐free MR signals. During scanning, MRI receive coil and EMI sensing coils simultaneously sample data within two windows (i.e., for MR data and EMI characterization data acquisition, respectively). Afterward, a residual U‐Net model is trained using synthetic MRI receive coil data and EMI sensing coil data acquired during EMI signal characterization window, to predict EMI‐free MR signals from signals acquired by MRI receive and EMI sensing coils. The trained model is then used to directly predict EMI‐free MR signals from data acquired by MRI receive and sensing coils during the MR signal‐acquisition window. This strategy was evaluated on an ultralow‐field 0.055T brain MRI scanner without any RF shielding and a 1.5T whole‐body scanner with incomplete RF shielding.Results: Deep‐DSP accurately predicted EMI‐free MR signals in presence of strong EMI. It outperformed recently developed EDITER and convolutional neural network methods, yielding better EMI elimination and enabling use of few EMI sensing coils. Furthermore, it could work well without dedicated EMI characterization data.Conclusion: Deep‐DSP presents an effective EMI elimination strategy that outperforms existing methods, advancing toward truly portable and patient‐friendly MRI. It exploits electromagnetic coupling between MRI receive and EMI sensing coils as well as typical MR signal characteristics. Despite its deep learning nature, Deep‐DSP framework is computationally simple and efficient.
- Open Access
- 22 September 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (38) , eadi9327
Deep learning enabled fast 3D brain MRI at 0.055 tesla
In recent years, there has been an intensive development of portable ultralow-field magnetic resonance imaging (MRI) for low-cost, shielding-free, and point-of-care applications. However, its quality is poor and scan time is long. We propose a fast acquisition and deep learning reconstruction framework to accelerate brain MRI at 0.055 tesla. The acquisition consists of a single average three-dimensional (3D) encoding with 2D partial Fourier sampling, reducing the scan time of T1- and T2-weighted imaging protocols to 2.5 and 3.2 minutes, respectively. The 3D deep learning leverages the homogeneous brain anatomy available in high-field human brain data to enhance image quality, reduce artifacts and noise, and improve spatial resolution to synthetic 1.5-mm isotropic resolution. Our method successfully overcomes low-signal barrier, reconstructing fine anatomical structures that are reproducible within subjects and consistent across two protocols. It enables fast and quality whole-brain MRI at 0.055 tesla, with potential for widespread biomedical applications.
- 22 September 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (38) , eadi9327
Open AccessDeep learning enabled fast 3D brain MRI at 0.055 tesla
In recent years, there has been an intensive development of portable ultralow-field magnetic resonance imaging (MRI) for low-cost, shielding-free, and point-of-care applications. However, its quality is poor and scan time is long. We propose a fast acquisition and deep learning reconstruction framework to accelerate brain MRI at 0.055 tesla. The acquisition consists of a single average three-dimensional (3D) encoding with 2D partial Fourier sampling, reducing the scan time of T1- and T2-weighted imaging protocols to 2.5 and 3.2 minutes, respectively. The 3D deep learning leverages the homogeneous brain anatomy available in high-field human brain data to enhance image quality, reduce artifacts and noise, and improve spatial resolution to synthetic 1.5-mm isotropic resolution. Our method successfully overcomes low-signal barrier, reconstructing fine anatomical structures that are reproducible within subjects and consistent across two protocols. It enables fast and quality whole-brain MRI at 0.055 tesla, with potential for widespread biomedical applications.
- Open Access
- 27 February 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 280-294
Calibrationless reconstruction of uniformly‐undersampled multi‐channel MR data with deep learning estimated ESPIRiT maps
To develop a truly calibrationless reconstruction method that derives An Eigenvalue Approach to Autocalibrating Parallel MRI (ESPIRiT) maps from uniformly-undersampled multi-channel MR data by deep learning. ESPIRiT, one commonly used parallel imaging reconstruction technique, forms the images from undersampled MR k-space data using ESPIRiT maps that effectively represents coil sensitivity information. Accurate ESPIRiT map estimation requires quality coil sensitivity calibration or autocalibration data. We present a U-Net based deep learning model to estimate the multi-channel ESPIRiT maps directly from uniformly-undersampled multi-channel multi-slice MR data. The model is trained using fully-sampled multi-slice axial brain datasets from the same MR receiving coil system. To utilize subject-coil geometric parameters available for each dataset, the training imposes a hybrid loss on ESPIRiT maps at the original locations as well as their corresponding locations within the standard reference multi-slice axial stack. The performance of the approach was evaluated using publicly available T1-weighed brain and cardiac data. The proposed model robustly predicted multi-channel ESPIRiT maps from uniformly-undersampled k-space data. They were highly comparable to the reference ESPIRiT maps directly computed from 24 consecutive central k-space lines. Further, they led to excellent ESPIRiT reconstruction performance even at high acceleration, exhibiting a similar level of errors and artifacts to that by using reference ESPIRiT maps. A new deep learning approach is developed to estimate ESPIRiT maps directly from uniformly-undersampled MR data. It presents a general strategy for calibrationless parallel imaging reconstruction through learning from the coil and protocol-specific data.
- 27 February 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 280-294
Open AccessCalibrationless reconstruction of uniformly‐undersampled multi‐channel MR data with deep learning estimated ESPIRiT maps
To develop a truly calibrationless reconstruction method that derives An Eigenvalue Approach to Autocalibrating Parallel MRI (ESPIRiT) maps from uniformly-undersampled multi-channel MR data by deep learning. ESPIRiT, one commonly used parallel imaging reconstruction technique, forms the images from undersampled MR k-space data using ESPIRiT maps that effectively represents coil sensitivity information. Accurate ESPIRiT map estimation requires quality coil sensitivity calibration or autocalibration data. We present a U-Net based deep learning model to estimate the multi-channel ESPIRiT maps directly from uniformly-undersampled multi-channel multi-slice MR data. The model is trained using fully-sampled multi-slice axial brain datasets from the same MR receiving coil system. To utilize subject-coil geometric parameters available for each dataset, the training imposes a hybrid loss on ESPIRiT maps at the original locations as well as their corresponding locations within the standard reference multi-slice axial stack. The performance of the approach was evaluated using publicly available T1-weighed brain and cardiac data. The proposed model robustly predicted multi-channel ESPIRiT maps from uniformly-undersampled k-space data. They were highly comparable to the reference ESPIRiT maps directly computed from 24 consecutive central k-space lines. Further, they led to excellent ESPIRiT reconstruction performance even at high acceleration, exhibiting a similar level of errors and artifacts to that by using reference ESPIRiT maps. A new deep learning approach is developed to estimate ESPIRiT maps directly from uniformly-undersampled MR data. It presents a general strategy for calibrationless parallel imaging reconstruction through learning from the coil and protocol-specific data.