AIAlexandru Petru Ion

Alexandru Petru Ion

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexandru Petru Ion has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Adrian Vasile Mureșan

    Department of Vascular Surgery, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania

    6 shared publications
  • Eliza Mihaela Arbănași

    Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania

    6 shared publications
  • Eliza Russu

    Department of Vascular Surgery, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania

    6 shared publications
  • Emil Marian Arbănași

    Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania

    6 shared publications
  • Claudiu Constantin Ciucanu

    Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania

    5 shared publications
  • Bogdan Andrei Cordoș

    Regenerative Medicine Laboratory, Center for Advanced Medical and Pharmaceutical Research, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 38 Gheorghe Marinescu Street, 540139 Targu Mures, Romania

    3 shared publications

Latest Publications

  • Open Access

    Optimizing Arterial Tissue Thickness Measurement Protocols: Digital Vernier Caliper Versus Digital Thickness Gauge

    by Alexandru Petru Ion, Alexandra Asztalos, Claudiu Constantin Ciucanu, Eliza Russu, Adrian Vasile Mureșan, Eliza-Mihaela Arbănași, Traian V. Chirilă, Gabriela Strnad, Emil-Marian Arbănași

    Background: The aim of this study is to analyze the reproducibility of sample thickness measurements taken by a non-experienced user by comparing a standard digital vernier caliper, with four different protocols, to a specialized thickness gauge. Methods: The current study is a methodological study where we examined the thickness of the porcine arterial wall in the thoracic aorta of six pigs. Two adjacent samples of 10 × 10 mm from each aorta were excised longitudinally from the anterior wall, resulting in twelve specimens. Five protocols were employed to measure the thickness of each sample. In four of these protocols, digital vernier calipers (Multicomp PRO MP012475) were utilized, while the fifth protocol utilized a specialized digital thickness gauge (Mitutoyo 547-500S, Mitutoyo Corp., Kawasaki, Japan). Results: We observed a higher average thickness of the samples during the initial measurement compared to the second measurement (1.11 ± 0.16 vs. 0.94 ± 0.17, p = 0.0319) with the first protocol and smaller values than those determined at the last measurement (0.93 ± 0.15 vs. 1.10 ± 0.15, p = 0.0135) for the third protocol. Further, with the digital vernier calipers, we recorded lower values for all four protocols than for the digital thickness gauge determinations. In addition, we computed the ratio of the thicknesses measured during the first, second, and third measurements to analyze how consistent the values were across the three consecutive measurements, with no difference regarding the third, fourth, and control protocols. Conclusions: The digital thickness gauge offers dependable measurements, regardless of the user’s expertise in assessing tissue thickness, and demonstrates a substantially higher reproducibility when compared to the digital vernier. We also found that taking an average of the thickness measurements from four specific points on each half of the sides or on each diagonal of each corner yielded consistently reliable results over time when using a standard digital vernier caliper instead of a specialized one.


  • Open Access

    Out-Patient versus In-Patient Arteriovenous Fistula Creation for Dialysis: Assessing Cost-Effectiveness Alongside Clinical Implications

    by Eliza Russu, Andreea-Cătălina Munteanu, Emil-Marian Arbănași, Ludovic-Alexandru Szanto, Reka Bartus, Elena Florea, Bogdan Corneliu Bandici, Eliza-Mihaela Arbănași, Alexandru Petru Ion, Bogdan Andrei Cordoș, et al.

    (1) Background: The surgical procedure to create an arteriovenous fistula (AVF) can be performed in either an ambulatory or in-patient hospital setting, depending on the case’s complexity, the anesthesia type used, and the patient’s comorbidities. The main scope of this study is to assess the cost-effectiveness and clinical implications of surgically creating an AVF in both ambulatory and in-hospital settings. (2) Methods: We conducted a retrospective observational study, in which we initially enrolled all patients with end-stage kidney disease (ESKD) admitted to the Vascular Surgery Department, Emergency County Hospital of Targu Mures, Romania, to surgically create an AVF for dialysis, between January 2020 and December 2022. The primary endpoint of this study is to assess the cost-effectiveness of surgically creating an AVF in an ambulatory vs. in-hospital setting by comparing the costs required for the two types of admissions. Further, the 116 patients enrolled in this study were divided into two groups based on their preference for hospitalization: out-patients and in-patients. (3) Results: Regarding in-patient comorbidities, there was a higher prevalence of peripheral artery disease (PAD) (p = 0.006), malignancy (p = 0.020), and previous myocardial infarction (p = 0.012). In addition, active smoking (p = 0.006) and obesity (p = 0.018) were more frequent among these patients. Regarding the laboratory data, the in-patients had lower levels of white blood cells (WBC) (p = 0.004), neutrophils count (p = 0.025), lymphocytes (p = 0.034), and monocytes (p = 0.032), but there were no differences between the two groups regarding the systemic inflammatory biomarkers or the AVF type. Additionally, we did not register any difference regarding the outcomes: local complications (p = 0.588), maturation failure (p = 0.267), and primary patency (p = 0.834). In our subsequent analysis, we discovered no significant difference between the hospitalization type chosen by patients regarding AVF primary patency failure (p = 0.195). We found no significant association between the hospitalization type and the recorded outcomes (all ps > 0.05) in both multivariate linear regression and Cox proportional hazard analysis. (4) Conclusions: In conclusion, there are no significant differences in the clinical implications, short-term and long-term complications of AVF for out-patient and in-patient admissions. Additionally, we found no variation in the costs associated with laboratory tests and surgical supplies for an AVF creation. Therefore, it is safe to perform ambulatory AVFs, which can reduce the risk of hospital-acquired infections and provide greater comfort to the patient.


  • Open Access

    Elevated Leukocyte Glucose Index Is Associated with Long-Term Arteriovenous Fistula Failure in Dialysis Patients

    by Adrian Vasile Mureșan, Elena Florea, Emil-Marian Arbănași, Réka Bartus, Eliza-Mihaela Arbănași, Alexandru Petru Ion, Bogdan Andrei Cordoș, Vasile Bogdan Halatiu, Raluca Niculescu, Adina Stoian, et al.

    (1) Background: Arteriovenous fistula (AVF) is the preferred type of vascular access for dialysis in patients with end-stage kidney disease (ESKD). However, the primary patency of AVF at one year is under 70% due to several risk factors and comorbidities. Leukocyte glucose index (LGI), a new biomarker based on blood leukocytes and glucose values, has been found to be associated with poor outcomes in cardiovascular disease. The aim of this study is to analyze the impact of LGI on the long-term primary patency of AVF following dialysis initiation. (2) Methods: We conducted a retrospective observational study in which we initially enrolled 158 patients with ESKD admitted to the Vascular Surgery Department of the Emergency County Hospital of Targu Mures, Romania, to surgically create an AVF for dialysis between January 2020 and July 2023. The primary endpoint was AVF failure, defined as the impossibility of performing a chronic dialysis session due to severe restenosis or AVF thrombosis. After follow-up, we categorized patients into two groups based on their AVF status: “functional AVF” for those with a permeable AVF and “AVF failure” for those with vascular access dysfunction. (3) Results: Patients with AVF failure had a higher prevalence of atrial fibrillation (p = 0.013) and diabetes (p = 0.028), as well as a higher LGI value (1.12 vs. 0.79, p < 0.001). At ROC analysis, LGI had the strongest association with the outcome, with an AUC of 0.729, and an optimal cut-off value of 0.95 (72.4% sensitivity and 68% specificity). In Kaplan–Meier survival analyses, patients in the highest tertile (T3) of LGI had a significantly higher incidence of AVF failure compared to those in tertile 1 (p = 0.019). Moreover, we found that patients with higher baseline LGI values had a significantly higher risk of AVF failure during follow-up (HR: 1.48, p = 0.003). The association is independent of age and sex (HR: 1.65, p = 0.001), cardiovascular risk factors (HR: 1.63, p = 0.012), and pre-operative vascular mapping determinations (HR: 3.49, p = 0.037). (4) Conclusions: In conclusion, high preoperative values of LGI are positively associated with long-term AVF failure. The prognostic role of the biomarker was independent of age, sex, cardiovascular risk factors, and pre-operative vascular mapping determinations.


  • Open Access

    Application of Adipose Stem Cells in 3D Nerve Guidance Conduit Prevents Muscle Atrophy and Improves Distal Muscle Compliance in a Peripheral Nerve Regeneration Model

    by Cristian Trâmbițaș, Bogdan Andrei Cordoș, Dorin Constantin Dorobanțu, Cristian Vintilă, Alexandru Petru Ion, Timea Pap, David Camelia, Claudiu Puiac, Emil Marian Arbănași, Claudiu Constantin Ciucanu, et al.

    Background: Peripheral nerve injuries (PNIs) represent a significant clinical problem, and standard approaches to nerve repair have limitations. Recent breakthroughs in 3D printing and stem cell technologies offer a promising solution for nerve regeneration. The main purpose of this study was to examine the biomechanical characteristics in muscle tissue distal to a nerve defect in a murine model of peripheral nerve regeneration from physiological stress to failure. Methods: In this experimental study, we enrolled 18 Wistar rats in which we created a 10 mm sciatic nerve defect. Furthermore, we divided them into three groups as follows: in Group 1, we used 3D nerve guidance conduits (NGCs) and adipose stem cells (ASCs) in seven rats; in Group 2, we used only 3D NGCs for seven rats; and in Group 3, we created only the defect in four rats. We monitored the degree of atrophy at 4, 8, and 12 weeks by measuring the diameter of the tibialis anterior (TA) muscle. At the end of 12 weeks, we took the TA muscle and analyzed it uniaxially at 10% stretch until failure. Results: In the group of animals with 3D NGCs and ASCs, we recorded the lowest degree of atrophy at 4 weeks, 8 weeks, and 12 weeks after nerve reconstruction. At 10% stretch, the control group had the highest Cauchy stress values compared to the 3D NGC group (0.164 MPa vs. 0.141 MPa, p = 0.007) and the 3D NGC + ASC group (0.164 MPa vs. 0.123 MPa, p = 0.007). In addition, we found that the control group (1.763 MPa) had the highest TA muscle stiffness, followed by the 3D NGC group (1.412 MPa), with the best muscle elasticity showing in the group in which we used 3D NGC + ASC (1.147 MPa). At failure, TA muscle samples from the 3D NGC + ASC group demonstrated better compliance and a higher degree of elasticity compared to the other two groups (p = 0.002 and p = 0.008). Conclusions: Our study demonstrates that the combination of 3D NGC and ASC increases the process of nerve regeneration and significantly improves the compliance and mechanical characteristics of muscle tissue distal to the injury site in a PNI murine model.


  • Open Access

    Rare Case of Raoultella planticola Infective Endocarditis after Mitral Valve Replacement Surgery

    by Diana Roxana Opriș, Victor Vacariu, Alexandru Petru Ion, Timea Szigyarto, Emil Marian Arbănași, Eliza Russu, Maria Mihaela Opriș

    Infective endocarditis remains a condition associated with high morbidity and mortality, regardless of advances in diagnosis and therapeutics. The etiology, microbiology, and epidemiology of infective endocarditis have changed in the last years, with healthcare-associated infective endocarditis being responsible for a myriad of cases. Raoultella planticola is rarely the cause of infective endocarditis. We present a 72-year-old Caucasian female with a history of mitral valve replacement for rheumatic valve disease two months before the current presentation, without any immunosuppressive pathologies, diagnosed with Raoultella planticola infective endocarditis. Long-drawn antibiotic treatment led to a full recovery with no evidence of recurrence or relapse. This report highlights the importance of a multimodal approach for the diagnosis of bacterial etiology, the importance of selection and duration of an appropriate antibiotic regimen, and the presence of a rare opportunistic bacteria that has proven pathogenicity in a wide range of organ systems, usually in patients with several risk factors.


  • Open Access

    Ledderhose’s Disease: An Up-to-Date Review of a Rare Non-Malignant Disorder

    by Alexandru Tomac, Alexandru Petru Ion, Diana Roxana Opriș, Eliza Mihaela Arbănași, Claudiu Constantin Ciucanu, Bogdan Corneliu Bandici, Cătălin Mircea Coșarcă, Diana Carina Covalcic, Adrian Vasile Mureșan

    Plantar fibromatosis (or Ledderhose’s disease) is a rare benign condition, difficult to treat, defined by gradual-growing nodules in the central medial part of the plantar fascia, with the possibility of sclerosis and shrinkage of the entire fascia or, rarely, contractures of the toes. From a histopathological point of view, it is linked to Dupuytren’s contracture of the hand and Peyronie’s disease of the penis, being part of a large group of fibromatoses, based on a proliferation of collagen and fibroblasts. Its etiology is still not fully understood, even though it has been associated with trauma, diabetes mellitus, use of anticonvulsants, frozen shoulder, alcohol consumption, and liver disease. Typically, ultrasound confirms the diagnosis, and magnetic resonance imaging is used for more aggressive and advanced types. Several conservative treatment techniques, such as steroid injections, verapamil, imatinib, radiation therapy, extracorporeal shock wave therapy, tamoxifen, sorafenib, mitomycin C, and collagenase, have been documented. When non-operative care fails, surgical measures may be considered, even though recurrence is expected. We attempted to provide a better understanding of this disease by covering all of the important aspects: its history, clinical and radiologic findings, diagnosis, pathophysiology features, conservative and surgical treatment, recurrence rate, and prognosis.


  • Open Access

    Ex-vivo Mechanical Augmentation of Human Saphenous Vein Graft By UV-A Irradiation in Emergency Vascular Reconstruction – Preliminary Results

    by Emil-Marian Arbănaşi, Shuko Suzuki, Claudiu Constantin Ciucanu, Adrian Vasile Mureşan, Cătălin Mircea Coşarcă, Traian Vasile Chirilă, Alexandru Petru Ion, Eliza-Mihaela Arbănaşi, Marius Mihai Harpa, Eliza Russu

    Introduction In vascular reconstruction in arterial trauma, ruptured abdominal aortic aneurysm or ruptured aneurysmal arteriovenous fistula, the challenge no longer lies in the surgical procedure itself, but rather the prevention of intimal hyperplasia, thrombosis and aneurysm formation, in parallel with extending as long as possible the patency of the grafts. The aim of this study is to present the preliminary findings of a novel non-ionizing radiation-based therapeutic method for stabilizing and strengthening the extracellular matrix of the venous wall, improving the biomechanical profile of the autologous graft used in myocardial and lower limb revascularization. Material and methods We developed the protocol and method for UV-A irradiation as a new method of mechanical augmentation of the resistance structure of the venous graft. Samples of the superficial femoral artery, superficial femoral vein, and great saphenous vein (GSV) were extracted from a 58-year-old patient who underwent above-the-knee amputation, and were prepared in 5 × 5 cm2 patches. Additionally, we analyzed the samples biomechanically biaxially with the BioTester® 5000, in which we established a 25% equibiaxial stretch. The GSV sample was also treated by UV-A irradiation after being kept in riboflavin 5′-phosphate monosodium salt for 30 min. Results After UV-A treatment of the GSV wall, we observed an important increase