Alexandros Nikolopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexandros Nikolopoulos has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Saer Samanipour
University of Amsterdam
6 shared publications - Denice van Herwerden
University of Amsterdam
3 shared publications - Viktoriia Turkina
University of Amsterdam
3 shared publications - Andrea F. G. Gargano
Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, Amsterdam 1098 XH, The Netherlands
2 shared publications - Bob W. J. Pirok
University of Amsterdam
2 shared publications - Jake William O'Brien
Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, QLD 4103, Australia
2 shared publications
Latest Publications
- Open Access
- 6 December 2025
- Published by Springer Nature in Journal of Cheminformatics
- Vol. 17 (1)
Ionization efficiency prediction of electrospray ionization mass spectrometry analytes based on molecular fingerprints and cumulative neutral losses
Quantification is a challenge for non-targeted analysis (NTA) with liquid chromatography–high resolution mass spectrometry (LC–HRMS), due to the lack of analytical standards. Quantification via structure-based predicted ionization efficiency (IE) has been shown to provide the highest accuracy in estimating concentration. However, achieving confident analyte identification is a challenging task, as multiple candidate structures may be likely. This uncertainty in identification limits the reliability of structure-based IE prediction models, since quantification can be severely compromised in cases of wrongly (tentatively) identified chemicals or lack of candidate structures. Here we investigate the possibility of using cumulative neutral losses from fragmentation spectra (i.e. MS2) to predict the log IE . The first model was based on molecular fingerprints and was applied on structurally identified analytes. PubChem fingerprints performed the best with the root-mean-square error (RMSE) of 0.72 log IE for the test set. The second model was based on the MS2 spectrum, expressed as cumulative neutral losses. This approach is applicable to analytes with unknown structures and showed promising results with RMSE of 0.79 log IE for the test set and 0.62 log IE for chromatographic features extracted from LC-HRMS data of tea extracts spiked with pesticides. The prediction models were compiled in a Julia package, which is publicly available on GitHub, and may be used as part of a quantification workflow to estimate concentrations of identified and unidentified compounds in NTA. Scientific contribution: This study expands the possibilities of standard free quantification for HRMS. It aims to provide reliable IE prediction for known substances by robust fingerprint calculation, and more importantly IE prediction for unknown substances using their MS2 fragmentation pattern. These workflows employ minimal method-specific variables, highlighting the tool generalizability.
- 6 December 2025
- Published by Springer Nature in Journal of Cheminformatics
- Vol. 17 (1)
Open AccessIonization efficiency prediction of electrospray ionization mass spectrometry analytes based on molecular fingerprints and cumulative neutral losses
Quantification is a challenge for non-targeted analysis (NTA) with liquid chromatography–high resolution mass spectrometry (LC–HRMS), due to the lack of analytical standards. Quantification via structure-based predicted ionization efficiency (IE) has been shown to provide the highest accuracy in estimating concentration. However, achieving confident analyte identification is a challenging task, as multiple candidate structures may be likely. This uncertainty in identification limits the reliability of structure-based IE prediction models, since quantification can be severely compromised in cases of wrongly (tentatively) identified chemicals or lack of candidate structures. Here we investigate the possibility of using cumulative neutral losses from fragmentation spectra (i.e. MS2) to predict the log IE . The first model was based on molecular fingerprints and was applied on structurally identified analytes. PubChem fingerprints performed the best with the root-mean-square error (RMSE) of 0.72 log IE for the test set. The second model was based on the MS2 spectrum, expressed as cumulative neutral losses. This approach is applicable to analytes with unknown structures and showed promising results with RMSE of 0.79 log IE for the test set and 0.62 log IE for chromatographic features extracted from LC-HRMS data of tea extracts spiked with pesticides. The prediction models were compiled in a Julia package, which is publicly available on GitHub, and may be used as part of a quantification workflow to estimate concentrations of identified and unidentified compounds in NTA. Scientific contribution: This study expands the possibilities of standard free quantification for HRMS. It aims to provide reliable IE prediction for known substances by robust fingerprint calculation, and more importantly IE prediction for unknown substances using their MS2 fragmentation pattern. These workflows employ minimal method-specific variables, highlighting the tool generalizability.
- Open Access
- 18 August 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 12 (9) , 1162-1168
A Novel Chemical-Space-Dependent Strategy for Compound Selection in Non-target LC-HRMS Method Development Using Physicochemical and Structural Data
The virtual chemical space of substances, including emerging contaminants relevant to the environment and exposome, is rapidly expanding. Non-targeted analysis (NTA) by liquid chromatography–high-resolution mass spectrometry (LC-HRMS) is useful in measuring broad chemical space regions. Internal standards are typically used to optimize the selectivity and sensitivity of NTA LC-HRMS methods, assuming a linear relationship between structure and behavior across all analytes. However, this assumption fails for large, heterogeneous chemical spaces, narrowing measurable coverage to structurally similar compounds. We present a data-driven strategy for unbiased sampling of candidate structures for NTA LC-HRMS method development from extensive chemical spaces, such as the U.S. EPA’s CompTox (>1 million chemicals). The workflow maximizes physicochemical/structural diversity using precomputed PubChem descriptors (e.g., molecular weight, XLogP) and grants LC-HRMS compatibility thanks to predicted mobility and ionization efficiency from molecular fingerprints. The resulting measurable compound lists (MCLs) provide broad, heterogeneous coverage for NTA method development, validation, and boundary assessment. Applied to the CompTox space, the approach yielded MCLs with greater chemical coverage and broader predicted LC-HRMS applicability than conventional “watch list” contaminants, offering a robust framework for enhancing NTA’s measurable chemical space while preserving diversity.
- 18 August 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 12 (9) , 1162-1168
Open AccessA Novel Chemical-Space-Dependent Strategy for Compound Selection in Non-target LC-HRMS Method Development Using Physicochemical and Structural Data
The virtual chemical space of substances, including emerging contaminants relevant to the environment and exposome, is rapidly expanding. Non-targeted analysis (NTA) by liquid chromatography–high-resolution mass spectrometry (LC-HRMS) is useful in measuring broad chemical space regions. Internal standards are typically used to optimize the selectivity and sensitivity of NTA LC-HRMS methods, assuming a linear relationship between structure and behavior across all analytes. However, this assumption fails for large, heterogeneous chemical spaces, narrowing measurable coverage to structurally similar compounds. We present a data-driven strategy for unbiased sampling of candidate structures for NTA LC-HRMS method development from extensive chemical spaces, such as the U.S. EPA’s CompTox (>1 million chemicals). The workflow maximizes physicochemical/structural diversity using precomputed PubChem descriptors (e.g., molecular weight, XLogP) and grants LC-HRMS compatibility thanks to predicted mobility and ionization efficiency from molecular fingerprints. The resulting measurable compound lists (MCLs) provide broad, heterogeneous coverage for NTA method development, validation, and boundary assessment. Applied to the CompTox space, the approach yielded MCLs with greater chemical coverage and broader predicted LC-HRMS applicability than conventional “watch list” contaminants, offering a robust framework for enhancing NTA’s measurable chemical space while preserving diversity.
- Open Access
- 30 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
A Novel Chemical Space Dependent Strategy for Compound Selection in Non-Target LC–HRMS Method Development Using Physicochemical and Structural Data
The virtual chemical space of substances, including emerging contaminants relevant to the environment and exposome, is in continuous expansion. The comprehensive measure of specific regions of chemical (sub)space relies on non-targeted analysis (NTA) using liquid chromatography high-resolution mass spectrometry (LC–HRMS). Internal standards are generally used to balance selectivity and sensitivity during NTA sample preparation and method development, assuming linearity between structure and behavior of all chemicals of interest. Since this assumption does not hold for wide and complex chemical subspaces, the actual measured space by NTA methods is consequently narrowed to a reduced set of chemically/structurally similar compounds. To understand the true coverage of the measurable chemical space by NTA methods, we present a data-driven strategy enabling the unbiased sampling of structures for LC–HRMS method development from a vast chemical subspace of interest (e.g., US-EPA CompTox >1 million chemicals). This workflow mines candidate structures maximizing their physicochemical diversity for reliable chemical subspace coverage. Measurable compound lists (MCLs) are effectively sampled using precomputed PubChem physicochemical properties (e.g., molecular weight and XLogP) and predicted mobility and ionization efficiency from molecular fingerprints. This approach significantly advances the selection of heterogeneous structures compatible with LC–HRMS analysis for NTA method development, validation, and method space boundary assessment while preserving the original diversity of the selected chemical space. The MCL sampled from CompTox space exhibited a greater chemical coverage and a broader predicted LC–HRMS applicability compared to common “watch list” contaminants.
- 30 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA Novel Chemical Space Dependent Strategy for Compound Selection in Non-Target LC–HRMS Method Development Using Physicochemical and Structural Data
The virtual chemical space of substances, including emerging contaminants relevant to the environment and exposome, is in continuous expansion. The comprehensive measure of specific regions of chemical (sub)space relies on non-targeted analysis (NTA) using liquid chromatography high-resolution mass spectrometry (LC–HRMS). Internal standards are generally used to balance selectivity and sensitivity during NTA sample preparation and method development, assuming linearity between structure and behavior of all chemicals of interest. Since this assumption does not hold for wide and complex chemical subspaces, the actual measured space by NTA methods is consequently narrowed to a reduced set of chemically/structurally similar compounds. To understand the true coverage of the measurable chemical space by NTA methods, we present a data-driven strategy enabling the unbiased sampling of structures for LC–HRMS method development from a vast chemical subspace of interest (e.g., US-EPA CompTox >1 million chemicals). This workflow mines candidate structures maximizing their physicochemical diversity for reliable chemical subspace coverage. Measurable compound lists (MCLs) are effectively sampled using precomputed PubChem physicochemical properties (e.g., molecular weight and XLogP) and predicted mobility and ionization efficiency from molecular fingerprints. This approach significantly advances the selection of heterogeneous structures compatible with LC–HRMS analysis for NTA method development, validation, and method space boundary assessment while preserving the original diversity of the selected chemical space. The MCL sampled from CompTox space exhibited a greater chemical coverage and a broader predicted LC–HRMS applicability compared to common “watch list” contaminants.
- Open Access
- 13 June 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Ionization Efficiency Prediction of Electrospray Ionization Mass Spectrometry Analytes based on Molecular Fingerprints and Cumulative Neutral Losses
Quantification is a challenge for non-targeted analysis (NTA) with liquid chromatography–high resolution mass spectrometry (LC–HRMS), due to the lack of analytical standards. Quantification via structure-based predicted ionization efficiency (IE) was found to provide the highest accuracy in estimating concentration. However, achieving confident analyte identification is a challenging task, as multiple candidate structures may be likely. This uncertainty in identification limits the reliability of structure-based IE prediction models, since quantification can be severely compromised in cases of wrongly (tentatively) identified chemicals or lack of candidate structures. Here we investigate the possibility of using cumulative neutral losses from fragmentation spectra (i.e. MS2) to predict the logIE. The first model was based on molecular fingerprints and was applied on structurally identified analytes. PubChem fingerprints performed the best with the root-mean-square error (RMSE) of 0.72 logIE units for the test set. The second model was based on the MS2 spectrum, expressed as cumulative neutral losses was used for model training. This approach is applicable to analytes with unknown structures and showed promising results with RMSE of 0.79 logIE units for the test set. The prediction models were compiled in a Julia package, which is publicly available on GitHub, and may be used as part of a quantification workflow to estimate concentrations of identified and unidentified compounds in NTA.
- 13 June 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessIonization Efficiency Prediction of Electrospray Ionization Mass Spectrometry Analytes based on Molecular Fingerprints and Cumulative Neutral Losses
Quantification is a challenge for non-targeted analysis (NTA) with liquid chromatography–high resolution mass spectrometry (LC–HRMS), due to the lack of analytical standards. Quantification via structure-based predicted ionization efficiency (IE) was found to provide the highest accuracy in estimating concentration. However, achieving confident analyte identification is a challenging task, as multiple candidate structures may be likely. This uncertainty in identification limits the reliability of structure-based IE prediction models, since quantification can be severely compromised in cases of wrongly (tentatively) identified chemicals or lack of candidate structures. Here we investigate the possibility of using cumulative neutral losses from fragmentation spectra (i.e. MS2) to predict the logIE. The first model was based on molecular fingerprints and was applied on structurally identified analytes. PubChem fingerprints performed the best with the root-mean-square error (RMSE) of 0.72 logIE units for the test set. The second model was based on the MS2 spectrum, expressed as cumulative neutral losses was used for model training. This approach is applicable to analytes with unknown structures and showed promising results with RMSE of 0.79 logIE units for the test set. The prediction models were compiled in a Julia package, which is publicly available on GitHub, and may be used as part of a quantification workflow to estimate concentrations of identified and unidentified compounds in NTA.
- Open Access
- 20 June 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1317, 342869
Exploring the chemical subspace of RPLC: A data driven approach
- 20 June 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1317, 342869
Open AccessExploring the chemical subspace of RPLC: A data driven approach
- Open Access
- 22 January 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Exploring the Chemical Subspace of RPLC: a Data Driven Approach
The chemical space is comprised of a vast number of possible structures, of which an unknown portion comprises the human and environmental exposome. Such samples are frequently analyzed using non-targeted analysis via liquid chromatography (LC) coupled to high-resolution mass spectrometry often employing a reversed phase (RP) column. However, prior to analysis, the contents of these samples are unknown and could be comprised of thousands of known and unknown chemical constituents. Moreover, it is unknown which part of the chemical space is sufficiently retained and eluted using RPLC. Therefore, we present a generic framework that uses a data driven approach to predict whether molecules fall "inside", "maybe" inside, or "outside" of the RPLC subspace. Firstly, three retention index random forest (RF) regression models were constructed that showed that molecular fingerprints are able to predict RPLC retention behavior. Secondly, these models were used to setup the dataset for building a RPLC RF classification model. The RPLC classification model was able to correctly predict whether a chemical belonged to the RPLC subspace with an accuracy of 92% for the testing set. Finally, applying this model to the 91737 small molecules (i.e., <=1000 Da) in NORMAN SusDat showed that 19.1% fall "outside" of the RPLC subspace. Knowing which chemicals are outside of the RPLC subspace can assist in reducing potential candidates for library searching and avoid screening for chemicals that will not be present in RPLC data.
- 22 January 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessExploring the Chemical Subspace of RPLC: a Data Driven Approach
The chemical space is comprised of a vast number of possible structures, of which an unknown portion comprises the human and environmental exposome. Such samples are frequently analyzed using non-targeted analysis via liquid chromatography (LC) coupled to high-resolution mass spectrometry often employing a reversed phase (RP) column. However, prior to analysis, the contents of these samples are unknown and could be comprised of thousands of known and unknown chemical constituents. Moreover, it is unknown which part of the chemical space is sufficiently retained and eluted using RPLC. Therefore, we present a generic framework that uses a data driven approach to predict whether molecules fall "inside", "maybe" inside, or "outside" of the RPLC subspace. Firstly, three retention index random forest (RF) regression models were constructed that showed that molecular fingerprints are able to predict RPLC retention behavior. Secondly, these models were used to setup the dataset for building a RPLC RF classification model. The RPLC classification model was able to correctly predict whether a chemical belonged to the RPLC subspace with an accuracy of 92% for the testing set. Finally, applying this model to the 91737 small molecules (i.e., <=1000 Da) in NORMAN SusDat showed that 19.1% fall "outside" of the RPLC subspace. Knowing which chemicals are outside of the RPLC subspace can assist in reducing potential candidates for library searching and avoid screening for chemicals that will not be present in RPLC data.