Matheus Bispo de Souza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Matheus Bispo de Souza has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Gilberto José Arruda
Programa em Recursos Naturais, Centro de Estudos em Recursos Naturais (CERNA), Universidade Estadual de Mato Grosso do Sul (UEMS), Dourados, Brazil
3 shared publications - Etenaldo Felipe Santiago
Programa em Recursos Naturais, Centro de Estudos em Recursos Naturais (CERNA), Universidade Estadual de Mato Grosso do Sul (UEMS), Dourados, Brazil
2 shared publications - Rafael Novaes Barros
Programa de Pós-Graduação em Recursos Naturais, Universidade Estadual de Mato Grosso do Sul (UEMS), Dourados, Brazil
2 shared publications - Sandro Marcio Lima
State University of Mato Grosso do Sul, Dourados 79804-970, MS, Brazil
2 shared publications - Antonio Rogério Fiorucci
Universidade Estadual de Mato Grosso do Sul
1 shared publication Daniela F. Duarte
1 shared publication
Latest Publications
- Open Access
- 10 August 2026
- Published by Springer Nature in Topics in Catalysis
- p. 1-16
Simultaneous Voltammetric Determination of Neurodegenerative Biomarkers at Nanomolar Levels Using a Fe3O4 Nanoparticle-Decorated Glassy Carbon Microsphere Nanocomposite
The precise monitoring of dopamine (DA), serotonin (5-HT), and L-tryptophan (L-Trp) is a critical challenge for the early diagnosis and management of neurodegenerative disorders, such as Alzheimer’s and Parkinson’s diseases. This work describes the development of a high-performance electrochemical platform based on a carbon paste electrode modified with a novel nanocomposite of glassy carbon microspheres (GCMs) decorated with magnetite (Fe 3 O 4 ) nanoparticles. The modifier was synthesized through a sustainable and efficient hydrothermal route, which ensured a uniform decoration of the GC surface and enhanced the material’s synergistic electrocatalytic properties. Under optimized conditions using square wave voltammetry (SWV) at pH 7.50, the sensor achieved wide linear response ranges: 0.04–10.00 µM for DA and 0.09–20.00 µM for 5-HT and L-Trp. Remarkably low limits of detection (LOD) were obtained for simultaneous determination: 2.8 nM for DA, 8.1 nM for 5-HT, and 6.7 nM for L-Trp. The proposed analytical method was successfully validated in complex biological matrices, including blood serum and synthetic urine, providing excellent recovery rates (near 100%) and high precision (RSD < 5%). Furthermore, the sensor demonstrated exceptional selectivity against common physiological interferents, long-term stability, and high reproducibility. These results demonstrate that the Fe 3 O 4 /GCM platform is a sensitive and promising tool with significant potential for future clinical diagnostics.
- 10 August 2026
- Published by Springer Nature in Topics in Catalysis
- p. 1-16
Open AccessSimultaneous Voltammetric Determination of Neurodegenerative Biomarkers at Nanomolar Levels Using a Fe3O4 Nanoparticle-Decorated Glassy Carbon Microsphere Nanocomposite
The precise monitoring of dopamine (DA), serotonin (5-HT), and L-tryptophan (L-Trp) is a critical challenge for the early diagnosis and management of neurodegenerative disorders, such as Alzheimer’s and Parkinson’s diseases. This work describes the development of a high-performance electrochemical platform based on a carbon paste electrode modified with a novel nanocomposite of glassy carbon microspheres (GCMs) decorated with magnetite (Fe 3 O 4 ) nanoparticles. The modifier was synthesized through a sustainable and efficient hydrothermal route, which ensured a uniform decoration of the GC surface and enhanced the material’s synergistic electrocatalytic properties. Under optimized conditions using square wave voltammetry (SWV) at pH 7.50, the sensor achieved wide linear response ranges: 0.04–10.00 µM for DA and 0.09–20.00 µM for 5-HT and L-Trp. Remarkably low limits of detection (LOD) were obtained for simultaneous determination: 2.8 nM for DA, 8.1 nM for 5-HT, and 6.7 nM for L-Trp. The proposed analytical method was successfully validated in complex biological matrices, including blood serum and synthetic urine, providing excellent recovery rates (near 100%) and high precision (RSD < 5%). Furthermore, the sensor demonstrated exceptional selectivity against common physiological interferents, long-term stability, and high reproducibility. These results demonstrate that the Fe 3 O 4 /GCM platform is a sensitive and promising tool with significant potential for future clinical diagnostics.
- 19 September 2023
- Published by Elsevier in Chemosphere
- Vol. 343, 140235
Toxicity of bisphenol A (BPA) and its analogues BPF and BPS on the free-floating macrophyte Salvinia biloba
- 19 September 2023
- Published by Elsevier in Chemosphere
- Vol. 343, 140235
Toxicity of bisphenol A (BPA) and its analogues BPF and BPS on the free-floating macrophyte Salvinia biloba