HSHelen Schneider

Helen Schneider

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Helen Schneider has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Generalizing Abstention for Noise-Robust Learning in Medical Image Segmentation

    by Wesam Moustafa, Hossam Elsafty, Helen Schneider, Lorenz Sparrenberg, Rafet Sifa

    Label noise is a critical problem in medical image segmentation, often arising from the inherent difficulty of manual annotation. Models trained on noisy data are prone to overfitting, which degrades their generalization performance. While a number of methods and strategies have been proposed to mitigate noisy labels in the segmentation domain, this area remains largely under-explored. The abstention mechanism has proven effective in classification tasks by enhancing the capabilities of Cross Entropy, yet its potential in segmentation remains unverified. In this paper, we address this gap by introducing a universal and modular abstention framework capable of enhancing the noise-robustness of a diverse range of loss functions. Our framework improves upon prior work with two key components: an informed regularization term to guide abstention behaviour, and a more flexible power-law-based auto-tuning algorithm for the abstention penalty. We demonstrate the framework's versatility by systematically integrating it with three distinct loss functions to create three novel, noise-robust variants: GAC, SAC, and ADS. Experiments on the CaDIS and DSAD medical datasets show our methods consistently and significantly outperform their non-abstaining baselines, especially under high noise levels. This work establishes that enabling models to selectively ignore corrupted samples is a powerful and generalizable strategy for building more reliable segmentation models. Our code is publicly available at https://github.com/wemous/abstention-for-segmentation.

  • Informed Deep Abstaining Classifier: Investigating Noise-Robust Training for Diagnostic Decision Support Systems Systems

    by Helen Schneider, Sebastian Nowak, Aditya Parikh, Yannik C. Layer, Maike Theis, Wolfgang Block, Alois M. Sprinkart, Ulrike Attenberger, Rafet Sifa


  • Open Access

    Mandibular Advancement Devices in OSA Patients: Impact on Occlusal Dynamics and Tooth Alignment Modifications—A Pilot Prospective and Retrospective Study

    by Aylin Uyaner, Helen Schneider, Aditya Parikh, Kathrin Paeske-Hinz, Anna Konermann

    Background: The widespread prevalence of obstructive sleep apnea (OSA) underscores the necessity for effective therapies. Mandibular advancement devices (MADs) have emerged as valid treatment for mild to moderate cases, despite the associated dental side effects. Methods: This study evaluates the nature, onset, and long-term manifestation of these side effects. In the prospective group (n = 12), dental impressions were taken pre-MAD-insertion and at intervals of three, six, nine, and twelve months post-insertion to monitor occlusal alterations. In the retrospective group, participants (n = 8) wearing MADs for 7 years at average underwent lateral cephalogram assessments to compare with pre-treatment X-rays. All participants completed a specific questionnaire. Statistical analysis was performed via t-test and with p < 0.05 as the significance level. Results: The majority of participants in both groups consistently used MADs and reported significant sleep quality improvements, rating common symptoms like jaw tension as negligible. In both the prospective group and the retrospective group, significant reductions in overjet were observed at multiple time points, with the prospective group showing reductions at six months (p = 0.001), nine months (p > 0.001), and twelve months (p = 0.019), while the retrospective group indicated a notable decrease between baseline and follow-up assessments after a mean of seven years of device wear (p = 0.004). A slight overbite increase of 0.2 mm was prospectively observed after one year, whereas a trend towards a minimal decrease over the long term was observed in the retrospective sample (p = 0.003). Noteworthy changes in angle class or lower incisor inclination were absent. Cephalograms revealed significant IOK-NL angle alterations with a mean of 98.2° before and 95.2° upon long-term treatment (p = 0.020). Conclusions: These findings suggest that MADs are effective in treating OSA with minor adverse effects. This study advocates for moderate mandibular protrusion to balance therapeutic efficacy with dental health considerations, crucial for optimizing treatment outcomes. Nonetheless, the limited sample size warrants caution when generalizing these results to the broader population.


  • Open Access

    Informed Deep Abstaining Classifier: Investigating noise-robust training for diagnostic decision support systems

    by Helen Schneider, Sebastian Nowak, Aditya Parikh, Yannik C. Layer, Maike Theis, Wolfgang Block, Alois M. Sprinkart, Ulrike Attenberger, Rafet Sifa

    Image-based diagnostic decision support systems (DDSS) utilizing deep learning have the potential to optimize clinical workflows. However, developing DDSS requires extensive datasets with expert annotations and is therefore costly. Leveraging report contents from radiological data bases with Natural Language Processing to annotate the corresponding image data promises to replace labor-intensive manual annotation. As mining "real world" databases can introduce label noise, noise-robust training losses are of great interest. However, current noise-robust losses do not consider noise estimations that can for example be derived based on the performance of the automatic label generator used. In this study, we expand the noise-robust Deep Abstaining Classifier (DAC) loss to an Informed Deep Abstaining Classifier (IDAC) loss by incorporating noise level estimations during training. Our findings demonstrate that IDAC enhances the noise robustness compared to DAC and several state-of-the-art loss functions. The results are obtained on various simulated noise levels using a public chest X-ray data set. These findings are reproduced on an in-house noisy data set, where labels were extracted from the clinical systems of the University Hospital Bonn by a text-based transformer. The IDAC can therefore be a valuable tool for researchers, companies or clinics aiming to develop accurate and reliable DDSS from routine clinical data.

  • Open Access

    Accuracy of Digital Orthodontic Treatment Planning: Assessing Aligner-Directed Tooth Movements and Exploring Inherent Intramaxillary Side Effects

    by Ludger Keilig, Anna Fittgen, Helen Schneider, Rafet Sifa, Jörg Schwarze, Christoph Bourauel, Anna Konermann

    Background: The attainment of precise posterior occlusion alignment necessitates a deeper understanding of the clinical efficacy of aligner therapy. This study aims to determine whether the treatment goals defined in the virtual planning of aligner therapy are effectively implemented in clinical practice, with a particular focus on the influence of distalization distances on potential vertical side effects. Methods: In this retrospective, non-interventional investigation, a cohort of 20 individuals undergoing Invisalign® treatment was examined. Pre- and post-treatment maxillary clinical and ClinCheck® casts were superimposed utilizing a surface–surface matching algorithm on palatal folds, median palatine raphe, and unmoved teeth as the stable references. The effectivity of planned versus clinical movements was evaluated. Groupings were based on distalization distances, planned vertical movements, and Class II elastic prescription. Statistics were performed with a two-sample t-test and p-value < 0.05. Results: Clinically achieved distalization was significantly lower than virtually planned distalization, regardless of additional vertical movements, where a lack of implementation was contingent upon the extent of distalization, with no mitigating effects observed with the application of Class II elastics. Intriguingly, no adverse vertical side effects were noted; however, the intended intrusions or extrusions, as per the therapeutic plans, remained unattainable regardless of the magnitude of distalization. Conclusions: These findings underscore the imperative for future investigations to delve deeper into the intricacies surrounding translational mesio-distal and vertical movements, thereby enhancing predictability within orthodontic practice. To facilitate successful clinical implementation of vertical and translational movements via aligners, the incorporation of sliders emerges as a promising strategy for bolstering anchorage reinforcement.


  • Symmetry-Aware Siamese Network: Exploiting Pathological Asymmetry for Chest X-Ray Analysis

    by Helen Schneider, Elif Cansu Yildiz, David Biesner, Yannik C. Layer, Benjamin Wulff, Sebastian Nowak, Maike Theis, Alois M. Sprinkart, Ulrike I. Attenberger, Rafet Sifa