Binbin Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Binbin Yu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Junye Shi
14 shared publicationsJiangping Chen
13 shared publicationsChenyi Qian
11 shared publicationsJiaxuan Wang
11 shared publicationsXiang Qiu
5 shared publicationsFengrui Zhang
4 shared publications
Latest Publications
- 26 September 2026
- Published by Elsevier in International Journal of Refrigeration
- Vol. 192
Experimental evaluation of R454C and R495A in an R134a-based air conditioning system for new-energy vehicles
- 26 September 2026
- Published by Elsevier in International Journal of Refrigeration
- Vol. 192
Experimental evaluation of R454C and R495A in an R134a-based air conditioning system for new-energy vehicles
- Open Access
- 2 July 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental study and simulation on the performance of a heat pump system with novel low-GWP R474A for new energy vehicles
This study evaluates the thermophysical properties, cycle performance, and system behavior of the next-generation low-GWP refrigerant R474A, a novel A2L-classified Hydro-Fluoro-Olefin mixture with a GWP of less than 4. This study employs an integrated approach combining thermodynamic analysis, system simulation, and experimental validation to evaluate the performance of R474A in a heat pump system, with comparisons made against R290 and R134a, as well as an investigation of its temperature uniformity. The results indicate that the optimal refrigerant charge for R474A in this heat pump system is 1250 g. In cooling mode, R474A achieves a COP exceeding 2.2 under low-load conditions and provides a cooling capacity of over 7000 W under high-load conditions. Notably, in battery cooling mode, the cooling capacity exceeds 10 kW with a COP above 3.6. R474A demonstrates superior cooling performance compared to both R134a and R290 across both low and high-load scenarios, while its COP is generally higher than that of the R290 secondary loop system. In heating mode, R474A maintains a COP above 2.1 under low-load conditions and delivers a heating capacity exceeding 4500 W under high-load extreme conditions. Its heating performance surpasses that of both R134a and R290 across all conditions, with consistently higher COP than the R290 secondary loop. Moreover, R474A overcame the operational limitations of R134a at extreme low temperatures. Furthermore, the temperature uniformity experiment confirms that R474A exhibits relatively minor temperature glide, ensuring satisfactory comfort performance. These findings highlight R474A’s significant potential as a sustainable alternative refrigerant for NEV heat pump applications.
- 2 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental study and simulation on the performance of a heat pump system with novel low-GWP R474A for new energy vehicles
This study evaluates the thermophysical properties, cycle performance, and system behavior of the next-generation low-GWP refrigerant R474A, a novel A2L-classified Hydro-Fluoro-Olefin mixture with a GWP of less than 4. This study employs an integrated approach combining thermodynamic analysis, system simulation, and experimental validation to evaluate the performance of R474A in a heat pump system, with comparisons made against R290 and R134a, as well as an investigation of its temperature uniformity. The results indicate that the optimal refrigerant charge for R474A in this heat pump system is 1250 g. In cooling mode, R474A achieves a COP exceeding 2.2 under low-load conditions and provides a cooling capacity of over 7000 W under high-load conditions. Notably, in battery cooling mode, the cooling capacity exceeds 10 kW with a COP above 3.6. R474A demonstrates superior cooling performance compared to both R134a and R290 across both low and high-load scenarios, while its COP is generally higher than that of the R290 secondary loop system. In heating mode, R474A maintains a COP above 2.1 under low-load conditions and delivers a heating capacity exceeding 4500 W under high-load extreme conditions. Its heating performance surpasses that of both R134a and R290 across all conditions, with consistently higher COP than the R290 secondary loop. Moreover, R474A overcame the operational limitations of R134a at extreme low temperatures. Furthermore, the temperature uniformity experiment confirms that R474A exhibits relatively minor temperature glide, ensuring satisfactory comfort performance. These findings highlight R474A’s significant potential as a sustainable alternative refrigerant for NEV heat pump applications.
- 17 March 2026
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 226
Parametric deformation of gyroid structures for enhanced thermo-hydraulic performance in heat exchangers
- 17 March 2026
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 226
Parametric deformation of gyroid structures for enhanced thermo-hydraulic performance in heat exchangers
- Open Access
- 9 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (29) , e23188
Sub‐Unit‐Cell Logic Governs Transport in TPMS Architectures
Next‐generation energy, thermal, and chemical systems require architectures capable of highly efficient transport across multiple length scales. Triply periodic minimal surfaces (TPMS), first conceptualized in 1865, offer inherently scalable geometries with exceptional transport potential, yet mechanistic links between topology and performance have remained elusive. Here we introduce a sub‐unit‐cell conduit framework that governs transport in TPMS architectures. By integrating crystallographic symmetry analysis with Voronoi tessellation, we show that each TPMS can be resolved into a network of identical intrinsic conduits oriented in different directions, with geometry and connectivity uniquely determined by topology. This framework reveals that transport efficiency is determined primarily by two conduit‐scale descriptors—conduit uniformity and conduit spatial density—while conduit surface area and connectivity play secondary roles. Building on these insights, we derive predictive descriptors and a performance quotient that link local conduit geometry to TPMS transport behavior independent of scale and operating conditions. The model identifies Fischer–Koch as a leading topology, which we validate using additively manufactured copper Fischer–Koch TPMS heat exchangers fabricated via green‐laser powder bed fusion. Experiments reveal up to a 156‐fold improvement in heat‐exchange efficiency (quantified by the j/f ratio) for the copper Fischer–Koch TPMS, compared with a conventional baseline, aligning closely with model predictions. This sub‐unit‐cell conduit approach provides a generalizable mechanistic basis for the rational design of high‐performance TPMS‐architected materials across diverse transport applications.
- 9 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (29) , e23188
Open AccessSub‐Unit‐Cell Logic Governs Transport in TPMS Architectures
Next‐generation energy, thermal, and chemical systems require architectures capable of highly efficient transport across multiple length scales. Triply periodic minimal surfaces (TPMS), first conceptualized in 1865, offer inherently scalable geometries with exceptional transport potential, yet mechanistic links between topology and performance have remained elusive. Here we introduce a sub‐unit‐cell conduit framework that governs transport in TPMS architectures. By integrating crystallographic symmetry analysis with Voronoi tessellation, we show that each TPMS can be resolved into a network of identical intrinsic conduits oriented in different directions, with geometry and connectivity uniquely determined by topology. This framework reveals that transport efficiency is determined primarily by two conduit‐scale descriptors—conduit uniformity and conduit spatial density—while conduit surface area and connectivity play secondary roles. Building on these insights, we derive predictive descriptors and a performance quotient that link local conduit geometry to TPMS transport behavior independent of scale and operating conditions. The model identifies Fischer–Koch as a leading topology, which we validate using additively manufactured copper Fischer–Koch TPMS heat exchangers fabricated via green‐laser powder bed fusion. Experiments reveal up to a 156‐fold improvement in heat‐exchange efficiency (quantified by the j/f ratio) for the copper Fischer–Koch TPMS, compared with a conventional baseline, aligning closely with model predictions. This sub‐unit‐cell conduit approach provides a generalizable mechanistic basis for the rational design of high‐performance TPMS‐architected materials across diverse transport applications.