Ali Kashefi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Kashefi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Foivos Leonidas Mouzakis
Institute of Physiology, RWTH Aachen University, Aachen, Germany
4 shared publications - Jan Spillner
Faculty of Medicine, Department of Thoracic Surgery, University Hospital Aachen, RWTH Aachen University, 52074 Aachen, Germany
4 shared publications - Khosrow Mottaghy
ECC Lab, Institute of Physiology, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
4 shared publications - Flutura Hima
Department of Thoracic Surgery, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
3 shared publications - Johannes Greven
Department of Thoracic Surgery, University Clinic RWTH Aachen, Aachen, Germany
2 shared publications - Lal Babu Khadka
RWTH Aachen University Hospital
2 shared publications
Latest Publications
- Open Access
- 2 September 2024
- Published by IntechOpen
Mathematical Modeling of Oxygen and Carbon Dioxide Exchange in Hollow Fiber Oxygenators
Artificial lungs are commonly used in cardiopulmonary-bypass surgery (CPB), extracorporeal life support (ECLS), and extracorporeal carbon dioxide removal therapy (ECCO2R). In this study, a semi-empirical model for O2 and CO2 transfer in an oxygenator was formulated to evaluate the gas exchange performance at different blood/gas flow rates and various inlet conditions. The model uses experimentally obtained mass transfer coefficients together with blood-gas and acid-base inlet parameters to determine the corresponding outlet values by considering the mass transfer equations for both O2 and CO2. Increasing the blood flow rate (17L/min) decreases pO2 at the outlet (from 376 to 120mmHg), but linearly increases the total oxygen transfer rate (OTR) from 76 to 450mL/min. CTR, the CO2 transfer rate (64648mL/min), depends primarily on the ratio of gas to blood flow rate (1:15:1). In addition, venous concentrations of O2CO2 play a pivotal role in the overall gas exchange efficiency of the oxygenator. Conclusively, a good agreement (R2=0.99) could be observed between the experimental data and the models predictions for OTR and CTR alike at standard inlet conditions. The model's capabilities can be extended by modeling gas exchange during CPB, ECLS and ECCO2R therapies for different connection configurations.
- 2 September 2024
- Published by IntechOpen
Open AccessMathematical Modeling of Oxygen and Carbon Dioxide Exchange in Hollow Fiber Oxygenators
Artificial lungs are commonly used in cardiopulmonary-bypass surgery (CPB), extracorporeal life support (ECLS), and extracorporeal carbon dioxide removal therapy (ECCO2R). In this study, a semi-empirical model for O2 and CO2 transfer in an oxygenator was formulated to evaluate the gas exchange performance at different blood/gas flow rates and various inlet conditions. The model uses experimentally obtained mass transfer coefficients together with blood-gas and acid-base inlet parameters to determine the corresponding outlet values by considering the mass transfer equations for both O2 and CO2. Increasing the blood flow rate (17L/min) decreases pO2 at the outlet (from 376 to 120mmHg), but linearly increases the total oxygen transfer rate (OTR) from 76 to 450mL/min. CTR, the CO2 transfer rate (64648mL/min), depends primarily on the ratio of gas to blood flow rate (1:15:1). In addition, venous concentrations of O2CO2 play a pivotal role in the overall gas exchange efficiency of the oxygenator. Conclusively, a good agreement (R2=0.99) could be observed between the experimental data and the models predictions for OTR and CTR alike at standard inlet conditions. The model's capabilities can be extended by modeling gas exchange during CPB, ECLS and ECCO2R therapies for different connection configurations.
- Open Access
- 18 August 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (8) , 1883
Molecular Hydrogen and Extracorporeal Gas Exchange: A Match Made in Heaven? An In Vitro Pilot Study
Extracorporeal circulation (ECC) is frequently implemented in a vast array of modalities such as hemodialysis, cardiopulmonary bypass, extracorporeal membrane oxygenation (ECMO), and others. Patients receiving any such therapy are frequently encumbered with chronic inflammation, which is inherently accompanied by oxidative stress. However, ECC treatments themselves are also responsible for sustaining or promoting inflammation. On these grounds, an in vitro study was designed to investigate the therapeutic potential of molecular hydrogen (H2) against pro-inflammatory agents in ECC settings. Five miniature ECMO circuits and a small vial (Control) were primed with heparinized blood from healthy adult donors (n = 7). Three of the ECMO systems were injected with lipopolysaccharide (LPS), out of which one was additionally treated with an H2 gas mixture. After 6 h, samples were drawn for the assessment of specific biomarkers (MCP-1, MPO, MDA-a, TRX1, and IL-6). Preliminary results indicate a progressive oxidative and inflammatory response between the six systems. Circulation has triggered inflammation and blood trauma, but the staggering influence of LPS in this outcome is indisputable. Accordingly, hydrogen’s remedial potential becomes immediately apparent as biomarker concentrations tend to be lower in the H2-handled circuit. Future research should have distinct objectives (e.g., dosage/duration/cycle of hydrogen administration) in order to ascertain the optimal protocol for patient treatment.
- 18 August 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (8) , 1883
Open AccessMolecular Hydrogen and Extracorporeal Gas Exchange: A Match Made in Heaven? An In Vitro Pilot Study
Extracorporeal circulation (ECC) is frequently implemented in a vast array of modalities such as hemodialysis, cardiopulmonary bypass, extracorporeal membrane oxygenation (ECMO), and others. Patients receiving any such therapy are frequently encumbered with chronic inflammation, which is inherently accompanied by oxidative stress. However, ECC treatments themselves are also responsible for sustaining or promoting inflammation. On these grounds, an in vitro study was designed to investigate the therapeutic potential of molecular hydrogen (H2) against pro-inflammatory agents in ECC settings. Five miniature ECMO circuits and a small vial (Control) were primed with heparinized blood from healthy adult donors (n = 7). Three of the ECMO systems were injected with lipopolysaccharide (LPS), out of which one was additionally treated with an H2 gas mixture. After 6 h, samples were drawn for the assessment of specific biomarkers (MCP-1, MPO, MDA-a, TRX1, and IL-6). Preliminary results indicate a progressive oxidative and inflammatory response between the six systems. Circulation has triggered inflammation and blood trauma, but the staggering influence of LPS in this outcome is indisputable. Accordingly, hydrogen’s remedial potential becomes immediately apparent as biomarker concentrations tend to be lower in the H2-handled circuit. Future research should have distinct objectives (e.g., dosage/duration/cycle of hydrogen administration) in order to ascertain the optimal protocol for patient treatment.
- Open Access
Has Extracorporeal Gas Exchange Performance Reached Its Peak?
Extracorporeal gas exchange therapies evolved considerably within the first three–four decades of their appearance, and have since reached a mature stage, where minor alterations and discrete fine-tuning might offer some incremental improvement. A different approach is introduced here, making use of modern, purely diffusive membrane materials, and taking advantage of the elevated concentration gradient ensuing from gas pressure buildup in the gas chamber of the oxygenator. An assortment of silicone membrane gas exchangers were tested in vitro as per a modified protocol in pursuance of assessing their gas exchange efficiency under both regular and high-pressure aeration conditions. The findings point to a stark performance gain when pressurization of the gas compartment is involved; a 40% rise above atmospheric pressure elevates oxygen transfer rate (OTR) by nearly 30%. Carbon dioxide transfer rate (CTR) does not benefit as much from this principle, yet it retains a competitive edge when higher gas flow/blood flow ratios are employed. Moreover, implementation of purely diffusive membranes warrants a bubble-free circulation. Further optimization of the introduced method ought to pave the way for in vivo animal trials, which in turn may potentially unveil new realms of gas exchange performance for therapies associated with extracorporeal circulation.
Open AccessHas Extracorporeal Gas Exchange Performance Reached Its Peak?
Extracorporeal gas exchange therapies evolved considerably within the first three–four decades of their appearance, and have since reached a mature stage, where minor alterations and discrete fine-tuning might offer some incremental improvement. A different approach is introduced here, making use of modern, purely diffusive membrane materials, and taking advantage of the elevated concentration gradient ensuing from gas pressure buildup in the gas chamber of the oxygenator. An assortment of silicone membrane gas exchangers were tested in vitro as per a modified protocol in pursuance of assessing their gas exchange efficiency under both regular and high-pressure aeration conditions. The findings point to a stark performance gain when pressurization of the gas compartment is involved; a 40% rise above atmospheric pressure elevates oxygen transfer rate (OTR) by nearly 30%. Carbon dioxide transfer rate (CTR) does not benefit as much from this principle, yet it retains a competitive edge when higher gas flow/blood flow ratios are employed. Moreover, implementation of purely diffusive membranes warrants a bubble-free circulation. Further optimization of the introduced method ought to pave the way for in vivo animal trials, which in turn may potentially unveil new realms of gas exchange performance for therapies associated with extracorporeal circulation.
- Open Access
- 27 September 2023
- Published by MDPI AG in Mathematics
- Vol. 11 (19) , 4088
Blood Gas Parameters and Acid–Base Balance during Extracorporeal Lung Support with Oxygenators: Semi-Empirical Evaluation
Membrane artificial lungs (oxygenators) are used in cardiopulmonary surgery as well as, in some cases, in severe lung disease to support the natural lung by means of ECMO (extracorporeal membrane oxygenation). The oxygen and carbon dioxide transfer rates of any oxygenator are usually assessed by considering several blood gas parameters, such as oxygen saturation, hemoglobin concentration, partial pressure of oxygen and carbon dioxide, bicarbonate concentration, and . Here, we report a set of semi-empirical equations that calculate such parameters directly from their partial pressures and assess the acid–base balance during ECMO. The implementation of this equation set permits the evaluation of any oxygenator, existing or prototypes in development, as well as the development of clinical decision-making tools for predicting the blood gas state and acid–base balance during surgical interventions and ECMO. The predicted results are then compared with experimental data obtained from in vitro gas exchange investigations with a commercial oxygenator using fresh porcine blood. The high correlation, , between the predicted and the experimental data suggests a possibility of using such empirical equations in the simulation of gas transfer in a cardiopulmonary system with an oxygenator for any venous inlet blood gas data and also for estimating the acid–base balance during such therapy.- 27 September 2023
- Published by MDPI AG in Mathematics
- Vol. 11 (19) , 4088
Open AccessBlood Gas Parameters and Acid–Base Balance during Extracorporeal Lung Support with Oxygenators: Semi-Empirical Evaluation
Membrane artificial lungs (oxygenators) are used in cardiopulmonary surgery as well as, in some cases, in severe lung disease to support the natural lung by means of ECMO (extracorporeal membrane oxygenation). The oxygen and carbon dioxide transfer rates of any oxygenator are usually assessed by considering several blood gas parameters, such as oxygen saturation, hemoglobin concentration, partial pressure of oxygen and carbon dioxide, bicarbonate concentration, and . Here, we report a set of semi-empirical equations that calculate such parameters directly from their partial pressures and assess the acid–base balance during ECMO. The implementation of this equation set permits the evaluation of any oxygenator, existing or prototypes in development, as well as the development of clinical decision-making tools for predicting the blood gas state and acid–base balance during surgical interventions and ECMO. The predicted results are then compared with experimental data obtained from in vitro gas exchange investigations with a commercial oxygenator using fresh porcine blood. The high correlation, , between the predicted and the experimental data suggests a possibility of using such empirical equations in the simulation of gas transfer in a cardiopulmonary system with an oxygenator for any venous inlet blood gas data and also for estimating the acid–base balance during such therapy.