Ali Sharbatian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Sharbatian has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Danesh Ashouri Vajari
Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg, Germany
3 shared publications - Thomas Stieglitz
Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
3 shared publications Akhilesh Kamtikar
Laboratory for Biomedical Microtechnology Department of Microsystems Engineering (IMTEK) University of Freiburg 79110 Freiburg Germany
1 shared publication- Kalyani Devkota
Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg, Germany
1 shared publication - Kevin Joseph
Department of Neurosurgery, Medical Center, University of Freiburg, Freiburg, Germany
1 shared publication - Ulrich G. Hofmann
University of Freiburg
1 shared publication
Latest Publications
- Open Access
In Search for Biomarkers Reflecting Neural Implant-Induced Tissue Response Dynamics
Extracellular matrix (ECM) remodeling is a fundamental determinant of neural tissue repair and implant integration, yet its conserved regulatory architecture remains undefined. While transcriptomic alterations following neural injury and implantation have been described, the ECM-centered programs that unify traumatic injury and neural implant responses remain unclear. Here, integrative systems-level transcriptomic analysis identifies a dominant and conserved ECM regulatory axis linking traumatic brain injury (BI), spinal cord injury (SCI), and neural implant–induced injury. By integrating transcriptomic datasets from brain and spinal cord injury models using weighted gene co-expression network analysis (WGCNA), six conserved ECM-associated gene modules are identified, with hyaluronan (HA)-centered networks emerging as the dominant and conserved regulatory axis across both injury types. Modules enriched for low-molecular-weight HA (LMW-HA) are linked to Toll-like receptor signaling and pro-inflammatory cytokine expression, whereas high-molecular-weight HA (HMW-HA)–associated modules correlate with Cd44 signaling, tissue stabilization and repair. Furthermore, independent validation in thin-film intracortical microelectrode datasets confirms robust activation of HA damage-associated molecular pattern (HA-DAMP) signaling following implantation, with 9/10 injury-derived modules preserved and 88% of transcripts exhibiting resolving temporal dynamics. These findings indicate that neural implants engage conserved trauma-associated ECM programs rather than a conventional foreign-body response, highlighting HA-related metabolisms. Given that HA fragments and HA-modifying enzymes are detectable in cerebrospinal fluid and peripheral circulation, HA-associated signatures may serve as minimally invasive biomarkers of neural injury and implant biocompatibility, enabling longitudinal monitoring and informing next-generation neural interface design.
Open AccessIn Search for Biomarkers Reflecting Neural Implant-Induced Tissue Response Dynamics
Extracellular matrix (ECM) remodeling is a fundamental determinant of neural tissue repair and implant integration, yet its conserved regulatory architecture remains undefined. While transcriptomic alterations following neural injury and implantation have been described, the ECM-centered programs that unify traumatic injury and neural implant responses remain unclear. Here, integrative systems-level transcriptomic analysis identifies a dominant and conserved ECM regulatory axis linking traumatic brain injury (BI), spinal cord injury (SCI), and neural implant–induced injury. By integrating transcriptomic datasets from brain and spinal cord injury models using weighted gene co-expression network analysis (WGCNA), six conserved ECM-associated gene modules are identified, with hyaluronan (HA)-centered networks emerging as the dominant and conserved regulatory axis across both injury types. Modules enriched for low-molecular-weight HA (LMW-HA) are linked to Toll-like receptor signaling and pro-inflammatory cytokine expression, whereas high-molecular-weight HA (HMW-HA)–associated modules correlate with Cd44 signaling, tissue stabilization and repair. Furthermore, independent validation in thin-film intracortical microelectrode datasets confirms robust activation of HA damage-associated molecular pattern (HA-DAMP) signaling following implantation, with 9/10 injury-derived modules preserved and 88% of transcripts exhibiting resolving temporal dynamics. These findings indicate that neural implants engage conserved trauma-associated ECM programs rather than a conventional foreign-body response, highlighting HA-related metabolisms. Given that HA fragments and HA-modifying enzymes are detectable in cerebrospinal fluid and peripheral circulation, HA-associated signatures may serve as minimally invasive biomarkers of neural injury and implant biocompatibility, enabling longitudinal monitoring and informing next-generation neural interface design.
- Open Access
- 12 March 2025
- Published by Wiley in Advanced Materials Interfaces
- Vol. 12 (9)
Assessing the Safety Margin for Micromotion‐Induced Strain at Electrode–Tissue Interface: A Finite Element Analysis via COMSOL
Brain movement significantly impacts the biocompatibility of neural probes, primarily due to continuous loading and strain on neural tissue. This study investigates the strain profile at the electrode–tissue interface under various brain displacements—vertical, lateral, diagonal, and torque—across different brain models (linear elastic, hyperelastic, and viscoelastic). The safety margin for tissue damage is assessed by evaluating a 5% strain threshold using two probe widths (30 µm and 100 µm) in tethered and floating configurations. The probe dimensions are informed by previously developed devices implanted in rats for 12 weeks, allowing to correlate the findings with existing immunohistochemical data. A comprehensive simulation studies accounting for various conditions, such as different brain displacements and physics, has not been reported elsewhere. These results challenge the conventional 5% strain threshold for tissue damage, revealing that strains below this critical limit may still pose risks depending on probe geometry and brain model. Furthermore, these simulations underscore the necessity of size‐dependent micromotion models for accurate predictions in untethered conditions. This work highlights the feasibility of integrating immunohistological data into simulation studies, offering valuable insights for researchers while minimizing the need for extensive animal testing during initial probe design phases.
- 12 March 2025
- Published by Wiley in Advanced Materials Interfaces
- Vol. 12 (9)
Open AccessAssessing the Safety Margin for Micromotion‐Induced Strain at Electrode–Tissue Interface: A Finite Element Analysis via COMSOL
Brain movement significantly impacts the biocompatibility of neural probes, primarily due to continuous loading and strain on neural tissue. This study investigates the strain profile at the electrode–tissue interface under various brain displacements—vertical, lateral, diagonal, and torque—across different brain models (linear elastic, hyperelastic, and viscoelastic). The safety margin for tissue damage is assessed by evaluating a 5% strain threshold using two probe widths (30 µm and 100 µm) in tethered and floating configurations. The probe dimensions are informed by previously developed devices implanted in rats for 12 weeks, allowing to correlate the findings with existing immunohistochemical data. A comprehensive simulation studies accounting for various conditions, such as different brain displacements and physics, has not been reported elsewhere. These results challenge the conventional 5% strain threshold for tissue damage, revealing that strains below this critical limit may still pose risks depending on probe geometry and brain model. Furthermore, these simulations underscore the necessity of size‐dependent micromotion models for accurate predictions in untethered conditions. This work highlights the feasibility of integrating immunohistological data into simulation studies, offering valuable insights for researchers while minimizing the need for extensive animal testing during initial probe design phases.
- Open Access
- 27 September 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1846
From Bioinspired Topographies toward Non-Wettable Neural Implants
The present study investigates different design strategies to produce non-wettable micropatterned surfaces. In addition to the classical method of measuring the contact angle, the non-wettability is also discussed by means of the immersion test. Inspired by non-wettable structures found in nature, the effects of features such as reentrant cavities, micropillars, and overhanging layers are studied. We show that a densely populated array of small diameter cavities exhibits superior non-wettability, with 65% of the cavities remaining intact after 24 h of full immersion in water. In addition, it is suggested that the wetting transition time is influenced by the length of the overhanging layer as well as by the number of columns within the cavity. Our findings indicate a non-wetting performance that is three times longer than previously reported in the literature for a small, densely populated design with cavities as small as 10 μm in diameter. Such properties are particularly beneficial for neural implants as they may reduce the interface between the body fluid and the solid state, thereby minimiing the inflammatory response following implantation injury. In order to assess the effectiveness of this approach in reducing the immune response induced by neural implants, further in vitro and in vivo studies will be essential.
- 27 September 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1846
Open AccessFrom Bioinspired Topographies toward Non-Wettable Neural Implants
The present study investigates different design strategies to produce non-wettable micropatterned surfaces. In addition to the classical method of measuring the contact angle, the non-wettability is also discussed by means of the immersion test. Inspired by non-wettable structures found in nature, the effects of features such as reentrant cavities, micropillars, and overhanging layers are studied. We show that a densely populated array of small diameter cavities exhibits superior non-wettability, with 65% of the cavities remaining intact after 24 h of full immersion in water. In addition, it is suggested that the wetting transition time is influenced by the length of the overhanging layer as well as by the number of columns within the cavity. Our findings indicate a non-wetting performance that is three times longer than previously reported in the literature for a small, densely populated design with cavities as small as 10 μm in diameter. Such properties are particularly beneficial for neural implants as they may reduce the interface between the body fluid and the solid state, thereby minimiing the inflammatory response following implantation injury. In order to assess the effectiveness of this approach in reducing the immune response induced by neural implants, further in vitro and in vivo studies will be essential.