KKKyleigh Kriener

Kyleigh Kriener

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kyleigh Kriener has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Mark John Midwinter

    School of Biomedical Sciences, Faculty of Health, Behavioural Science and Medicine The University of Queensland Brisbane Queensland Australia

    2 shared publications
  • Raushan Lala

    School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, Brisbane, QLD 4072, Australia

    2 shared publications
  • Bryn Rubin

    School of Biomedical Sciences, The University of Queensland, Brisbane, Qld, Australia

    1 shared publication
  • Christopher Futter

    Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women’s Hospital, Brisbane, QLD, Australia

    1 shared publication
  • Edward Frails

    Department of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA, United States

    1 shared publication
  • Grant Robison

    School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, Brisbane, QLD 4072, Australia

    1 shared publication

Latest Publications

  • Open Access

    Investigating the Reliability of Shore Hardness in the Design of Procedural Task Trainers

    by Kyleigh Kriener, Kate Sinclair, Grant Robison, Raushan Lala, Hayley Finley, William Jase Richardson, Mark J. Midwinter

    The haptic fidelity of biomimetic materials used in the design of procedural task trainers is of growing interest to the medical community. Shore hardness has been proposed as a method for assessing tissue biomechanics and replicating the results as a way to increase the fidelity of biomimetics to tissues. However, there is limited research on the reliability of human tissue measurements using Shore scales. Using human tissues (internal carotid artery [ICA], internal jugular vein [IJV], vagus nerve [VN], sternocleidomastoid muscle [SCM], and overlying skin [skin]), this study evaluates (1) the inter-rater reliability of Shore hardness measurements, (2) examines the relationship between tissue thickness and hardness, and (3) investigates the impact of a measurement method (freehand vs. durometer stand). Preserved tissues, specifically a liver and components of the anterior triangle of the neck, were extracted from cadavers and measured by three independent raters using digital Shore durometers. Testing revealed that although Shore A demonstrated better inter-rater reliability compared to Shore OO, both scales exhibited poor-to-moderate reliability. ICC values for Shore A ranged from 0.21 to 0.80 and were statistically significant (p < 0.05) for all tissue types except the SCM. In contrast, Shore OO demonstrated poorer reliability, with ICC values ranging from 0.00 to 0.41. The ICC values were only significant for the ICA, IJV, and VN (p < 0.05). An inverse correlation between tissue thickness and hardness on the Shore A scale was found for all tissues and was significant (p < 0.05) for ICA, VN, and skin. There were mixed results for the correlation between tissue thickness and hardness on the Shore OO scale (−0.06–0.92), and only IJV had a statistically significant correlation (p < 0.05). Finally, the median hardness values on the Shore OO scale were significantly greater when measured using a durometer stand vs. freehand (Z = 4.78, p < 0.05). In summary, when using appropriate standards and addressing the challenges of tissue thickness and variability in freehand measures, Shore hardness has the potential to be used by clinicians in the clinical setting and in the selection of biomimetic materials in the design of task trainers.


  • Open Access

    Mechanical Characterization of the Human Abdominal Wall Using Uniaxial Tensile Testing

    by Kyleigh Kriener, Raushan Lala, Ryan Anthony Peter Homes, Hayley Finley, Kate Sinclair, Mason Kelley Williams, Mark John Midwinter

    It is generally accepted that the human abdominal wall is comprised of skin, subcutaneous tissues, muscles and their aponeuroses, and the parietal peritoneum. Understanding these layers and their mechanical properties provides valuable information to those designing procedural skills trainers, supporting surgical procedures (hernia repair), and engineering-based work (in silico simulation). However, there is little literature available on the mechanical properties of the abdominal wall in layers or as a composite. This work characterizes the tensile properties of the human abdominal wall by layer and as a partial composite. Tissues were collected from fresh-never-frozen and fresh-frozen cadavers and tested in uniaxial tension at a rate of 5 mm/min until failure. Stress-strain curves were created for each sample, and the values for elastic moduli, ultimate tensile strength, and strain at failure were obtained. The experimental outcomes from this study demonstrated variation of tensile properties within and between tissues. The data also suggest that the tensile properties of composite abdominal walls are not additive. Ultimately, this body of work contributes to a deeper comprehension of these mechanical properties and will serve to enhance patient care, refine surgical interventions, and assist with more sophisticated engineering solutions.


  • Applied use of biomechanical measurements from human tissues for the development of medical skills trainers: a scoping review

    by Kyleigh Kriener, Harrison Whiting, Nicholas Storr, Ryan Homes, Raushan Lala, Robert Gabrielyan, Jasmine Kuang, Bryn Rubin, Edward Frails, Hannah Sandstrom, et al.

    Objective: The objective of this review was to identify quantitative biomechanical measurements of human tissues, the methods for obtaining these measurements, and the primary motivations for conducting biomechanical research. Introduction: Medical skills trainers are a safe and useful tool for clinicians to use when learning or practicing medical procedures. The haptic fidelity of these devices is often poor, which may be because the synthetic materials chosen for these devices do not have the same mechanical properties as human tissues. This review investigates a heterogeneous body of literature to identify which biomechanical properties are available for human tissues, the methods for obtaining these values, and the primary motivations behind conducting biomechanical tests. Inclusion criteria: Studies containing quantitative measurements of the biomechanical properties of human tissues were included. Studies that primarily focused on dynamic and fluid mechanical properties were excluded. Additionally, studies only containing animal, in silico, or synthetic materials were excluded from this review. Methods: This scoping review followed the JBI methodology for scoping reviews and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Sources of evidence were extracted from CINAHL (EBSCO), IEEE Xplore, MEDLINE (PubMed), Scopus, and engineering conference proceedings. The search was limited to the English language. Two independent reviewers screened titles and abstracts as well as full-text reviews. Any conflicts that arose during screening and full-text review were mediated by a third reviewer. Data extraction was conducted by 2 independent reviewers and discrepancies were mediated through discussion. The results are presented in tabular, figure, and narrative formats. Results: Data were extracted from a total of 186 full-text publications. All of the studies, except for 1, were experimental. Included studies came from 33 countries, with the majority coming from the United States. Ex vivo methods were the predominant approach for extracting human tissue samples, and the most commonly studied tissue type was musculoskeletal. In this study, nearly 200 unique biomechanical values were reported, and the most commonly reported value was Young’s (elastic) modulus. The most common type of mechanical test performed was tensile testing, and the most common reason for testing human tissues was to characterize biomechanical properties. Although the number of published studies on biomechanical properties of human tissues has increased over the past 20 years, there are many gaps in the literature. Of the 186 included studies, only 7 used human tissues for the design or validation of medical skills training devices. Furthermore, in studies where biomechanical values for human tissues have been obtained, a lack of standardization in engineering assumptions, methodologies, and tissue preparation may implicate the usefulness of these values. Conclusions: This review is the first of its kind to give a broad overview of the biomechanics of human tissues in the published literature. With respect to high-fidelity haptics, there is a large gap in the published literature. Even in instances where biomechanical values are available, comparing or using these values is difficult. This is likely due to the lack of standardization in engineering assumptions, testing methodology, and reporting of the results. It is recommended that journals and experts in engineering fields conduct further research to investigate the feasibility of implementing reporting standards. Review registration: Open Science Framework https://osf.io/fgb34