JJJulia I. Jäger

Julia I. Jäger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julia I. Jäger has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Road transport of trapped antiprotons

    by M. Leonhardt, J. Morgner, F. Abbass, K. K. Anjum, B. Arndt, R. P. Czampiel, N. Daehnhardt, S. Endoh, T. Imamura, J. I. Jäger, et al.

    Low-energy antiprotons confined in ultrahigh-vacuum Penning traps 1 enable precision investigations of charge, parity and time-reversal (CPT) invariance 2 to test the fundamental symmetry between matter and antimatter. These studies are driven by the search for physics beyond the standard model of particle physics, including efforts to explain the observed cosmological matter–antimatter asymmetry. Until now, such experiments have only been possible at CERN’s Antimatter Factory 3,4 . At present, magnetic-field fluctuations caused by the facility operation limit the sensitivity of trapped-antiproton precision measurements 5 , which provide the most stringent matter–antimatter symmetry tests in the baryon sector 6–9 . This has inspired us to develop the cryogenic, open and transportable Penning-trap system BASE-STEP 5,10 , designed to relocate antiprotons into low-noise offline laboratories, a strategy expected to enable at least 100-fold improved CPT tests 9,11 . Here we demonstrate the road transport of antiprotons trapped in BASE-STEP. Ninety-two trapped antiprotons have been transported outside the Antimatter Factory along a 7.5-km route without particle loss or measurable degradation of the trap vacuum. This achievement marks the starting point for a new era of antiproton precision measurements 8,12 in dedicated low-noise offline laboratory environments.


  • Open Access

    Road Transport of Trapped Antiprotons

    by Christian Smorra, Marcel Leonhardt, Jonathan Morgner, Fatma Abbass, Khwaish Anjum, Bela Arndt, Raphael Czampiel, Nuno Daehnhardt, Satoshi Endo, Tomoka Imamura, et al.

    Low-energy antiprotons confined in ultra-high vacuum Penning traps enable precision investigations of charge, parity, and time-reversal (CPT) invariance to test the fundamental symmetry between matter and antimatter. These studies are driven by the search for physics beyond the Standard Model of particle physics, including efforts to explain the observed cosmological matter–antimatter asymmetry. To date, such experiments have only been possible at CERN’s Antimatter Factory (AMF). Magnetic-field fluctuations caused by the facility operation currently limit the sensitivity of trapped-antiproton precision measurements, which currently provide the most stringent matter/antimatter symmetry tests in the baryon sector. This has inspired us to develop the cryogenic, open, and transportable Penning-trap system BASE-STEP, designed to relocate antiprotons into low-noise offline laboratories, a strategy expected to enable at least 100-fold improved CPT tests. Here, we demonstrate the first road transport of antiprotons trapped in BASE-STEP. 92 trapped antiprotons have been transported for the first time outside of the AMF over a 7.5 km route without particle loss or measurable degradation of the trap vacuum. This achievement marks the starting point for a new era of antiproton precision measurements in dedicated low-noise offline laboratory environments.


  • Open Access

    Proton transport from the antimatter factory of CERN

    by M. Leonhardt, D. Schweitzer, F. Abbass, K. K. Anjum, B. Arndt, S. Erlewein, S. Endoh, P. Geissler, T. Imamura, J. I. Jäger, et al.

    Precision measurements using low-energy antiprotons, exclusively available at the antimatter factory (AMF) of CERN 1 , offer stringent tests of charge–parity–time (CPT) invariance, which is a fundamental symmetry in the Standard Model of particle physics 2 . These tests have been realized, for example, in antiprotonic helium 3 and antihydrogen 4 . In our cryogenic Penning-trap experiments 5 , we measure the magnetic moments 6,7 and charge-to-mass ratios of protons and antiprotons and now provide the most precise test of CPT invariance in the baryon sector 8 . Our experiments are limited by magnetic field fluctuations imposed by the decelerators in the AMF; therefore, we are advancing the relocation of antiprotons to dedicated precision laboratories. Here we present the successful transport of a trapped proton cloud from the AMF using BASE-STEP 9 —a transportable, superconducting, autonomous and open Penning-trap system that can distribute antiprotons into other experiments. We transferred the trapped protons from our experimental area at the AMF onto a truck and transported them across the Meyrin site of CERN, demonstrating autonomous operation without external power for 4 h and loss-free proton relocation. We thereby confirm the feasibility of transferring particles into low-noise laboratories in the vicinity of the AMF and of using a power generator on the truck 10 to reach laboratories throughout Europe. This marks the potential start of a new era in precision antimatter research, enabling low-noise measurements of antiprotons, the charged antimatter ions $${\bar{{\rm{H}}}}^{+}$$ H ¯ + 11 and $${\bar{{\rm{H}}}}_{2}^{-}$$ H ¯ 2 − (ref. 12 ), and other accelerator-produced ions, such as hydrogen-like lead or uranium ions 13,14 .


  • Open Access

    Orders of Magnitude Improved Cyclotron-Mode Cooling for Nondestructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons

    by B. M. Latacz, M. Fleck, J. I. Jäger, G. Umbrazunas, B. P. Arndt, S. R. Erlewein, E. J. Wursten, J. A. Devlin, P. Micke, F. Abbass, et al.

    We demonstrate efficient subthermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures T+=E+/kB below 200 mK in preparation times shorter than 500 s. This corresponds to the fastest resistive single-particle cyclotron cooling to subthermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error rate <0.000 023, more than 3 orders of magnitude better than in previous best experiments. This method has enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter and antimatter symmetry, high-precision mass spectrometry, and measurements of electron g factors bound to highly charged ions that test quantum electrodynamics and establish standards for magnetometry.


  • Open Access

    Image-Current Mediated Sympathetic Laser Cooling of a Single Proton in a Penning Trap Down to 170 mK Axial Temperature

    by C. Will, M. Wiesinger, P. Micke, H. Yildiz, T. Driscoll, S. Kommu, F. Abbass, B. P. Arndt, B. B. Bauer, S. Erlewein, et al.

    We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled Be+9. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone toward the next generation of high-precision Penning-trap measurements with exotic particles.


  • Open Access

    BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies

    by C. Smorra, F. Abbass, D. Schweitzer, M. Bohman, J. D. Devine, Y. Dutheil, A. Hobl, B. Arndt, B. B. Bauer, J. A. Devlin, et al.

    Currently, the world’s only source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of fundamental interactions and their symmetries. However, magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of charge, parity, and time-reversal invariance with antiprotons and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.


  • Open Access

    Ultra-thin polymer foil cryogenic window for antiproton deceleration and storage

    by B. M. Latacz, B. P. Arndt, J. A. Devlin, S. R. Erlewein, M. Fleck, J. I. Jäger, P. Micke, G. Umbrazunas, E. Wursten, F. Abbass, et al.

    We present the design and characterization of a cryogenic window based on an ultra-thin aluminized biaxially oriented polyethylene terephthalate foil at T < 10 K, which can withstand a pressure difference larger than 1 bar at a leak rate <1×10−9 mbar l/s. Its thickness of ∼1.7 μm makes it transparent to various types of particles over a broad energy range. To optimize the transfer of 100 keV antiprotons through the window, we tested the degrading properties of different aluminum coated polymer foils of thicknesses between 900 and 2160 nm, concluding that 1760 nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of seven holes with a diameter of 1 mm and will transmit up to 2.5% of the injected 100 keV antiproton beam delivered by the Antiproton Decelerator and Extra Low ENergy Antiproton ring facility of CERN.


  • Open Access

    Dissociative Recombination of Rotationally Cold OH+ and Its Implications for the Cosmic Ray Ionization Rate in Diffuse Clouds

    by Ábel Kálosi, Lisa Gamer, Manfred Grieser, Robert von Hahn, Leonard W. Isberner, Julia I. Jäger, Holger Kreckel, David A. Neufeld, Daniel Paul, Daniel W. Savin, et al.

    Observations of OH+ are used to infer the interstellar cosmic ray ionization rate in diffuse atomic clouds, thereby constraining the propagation of cosmic rays through and the shielding by interstellar clouds, as well as the low energy cosmic ray spectrum. In regions where the H2-to-H number density ratio is low, dissociative recombination (DR) is the dominant destruction process for OH+ and the DR rate coefficient is important for predicting the OH+ abundance and inferring the cosmic ray ionization rate. We have experimentally studied DR of electronically and vibrationally relaxed OH+ in its lowest rotational levels, using an electron–ion merged-beams setup at the Cryogenic Storage Ring. From these measurements, we have derived a kinetic temperature rate coefficient applicable to diffuse cloud chemical models, i.e., for OH+ in its electronic, vibrational, and rotational ground level. At typical diffuse cloud temperatures, our kinetic temperature rate coefficient is a factor of ∼5 times larger than the previous experimentally derived value and a factor of ∼33 times larger than the value calculated by theory. Our combined experimental and modeling results point to a significant increase for the cosmic ray ionization rate inferred from observations of OH+ and H2O+, corresponding to a geometric mean of (6.6 ± 1.0) × 10−16 s−1, which is more than a factor of 2 larger than the previously inferred values of the cosmic ray ionization rate in diffuse atomic clouds. Combined with observations of diffuse and dense molecular clouds, these findings indicate a greater degree of cosmic ray shielding in interstellar clouds than has been previously inferred.