Osamah R. S. Alkhafaji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Osamah R. S. Alkhafaji has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Nabil J. Yasin
Engineering Technical College - Baghdad, Middle Technical University, Baghdad, Iraq
2 shared publicationsAudai H. Al-Abbas
Alfurat Alawsat Technical University, Kufa, Iraq- Technical College Almossaib, Kufa, Iraq
1 shared publicationAudai Hussain Al-Abbas
Almosaib Technical College, Alfurat Alawsat Technical University, Kufa , Iraq
1 shared publication- Audai Hussein Al-Abbas
Mechanical Power Engineering Department Mussaib Technical College Al-Furat Al
1 shared publication Firas Basim Ismail
1 shared publication- Majid Hameed Majeed
Air Conditioning Engineering Techniques, Technical Engineering College Baghdad, Middle Technical University, Baghdad, Iraq
1 shared publication
Latest Publications
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3203 (1) , 030007
The thermal performance of the thermosiphon under different parameters: Review study
Nowadays, the increase of the consumed energy within cooling applications is still high. Therefore, enhancements and advancements of the thermal performance for Nowadays, the increase of the consumed energy within cooling applications is still high. Therefore, enhancements and advancements of the thermal performance for
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3203 (1) , 030007
The thermal performance of the thermosiphon under different parameters: Review study
Nowadays, the increase of the consumed energy within cooling applications is still high. Therefore, enhancements and advancements of the thermal performance for Nowadays, the increase of the consumed energy within cooling applications is still high. Therefore, enhancements and advancements of the thermal performance for
- Open Access
- 10 November 2023
- Published by Middle Technical University in Journal of Techniques
- Vol. 5 (4) , 115-130
Experimental Study of the Wickless Heat Pipe Heat Exchanger by Using Nano Fluid
The use of wickless heat pipe heat exchangers has been improving a wide range of thermal applications such as solar water heaters. Therefore, more scientific research needs to be conducted to improve its performance. In the present study, a wickless heat pipe heat exchanger test rig has been designed and fabricated to investigate the effect of different parameters on its performance. Two different heat pipe working fluids have been used namely pure water and water with nanoparticles (Al2O3) using different fluid volume ratios (20%,40%,60%,80%, and 100%). The concentrations of the nanoparticles in water range between 1.3 and 7 % wt. For the heat exchanger, various inlet hot air temperatures (50, 55, and 60 oC) have been tested at the hot side (heat pipe evaporator) whereas the inlet temperature of the cold side (heat pipe condenser) has been maintained at 20 oC. The effect of airflow Reynolds number has also been examined with a range of 2583-20664. Results showed that the best heat exchanger effectiveness is achieved at a Reynolds number of 10332 and nanoparticles concentration of 7% wt. Also, the use of nanoparticles reduced the thermal resistance in the heat pipe due to the significant reduction in its surface temperature compared to that of pure water.
- 10 November 2023
- Published by Middle Technical University in Journal of Techniques
- Vol. 5 (4) , 115-130
Open AccessExperimental Study of the Wickless Heat Pipe Heat Exchanger by Using Nano Fluid
The use of wickless heat pipe heat exchangers has been improving a wide range of thermal applications such as solar water heaters. Therefore, more scientific research needs to be conducted to improve its performance. In the present study, a wickless heat pipe heat exchanger test rig has been designed and fabricated to investigate the effect of different parameters on its performance. Two different heat pipe working fluids have been used namely pure water and water with nanoparticles (Al2O3) using different fluid volume ratios (20%,40%,60%,80%, and 100%). The concentrations of the nanoparticles in water range between 1.3 and 7 % wt. For the heat exchanger, various inlet hot air temperatures (50, 55, and 60 oC) have been tested at the hot side (heat pipe evaporator) whereas the inlet temperature of the cold side (heat pipe condenser) has been maintained at 20 oC. The effect of airflow Reynolds number has also been examined with a range of 2583-20664. Results showed that the best heat exchanger effectiveness is achieved at a Reynolds number of 10332 and nanoparticles concentration of 7% wt. Also, the use of nanoparticles reduced the thermal resistance in the heat pipe due to the significant reduction in its surface temperature compared to that of pure water.
- 31 August 2023
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 41 (4) , 1052-1062
Thermal Performance Optimization of Perforated Fins for Flat Plate Heat Sinks Using CFD Approach
- 31 August 2023
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 41 (4) , 1052-1062
Thermal Performance Optimization of Perforated Fins for Flat Plate Heat Sinks Using CFD Approach
- Open Access
- 1 January 2023
- Published by Chaoyang University of Technology (IJASE) in International Journal of Applied Science and Engineering
- Vol. 20 (3) , 1-12
Optimization of wickless heat pipe heat exchanger using R1234-yf and ethanol as working fluids
This experimental study investigates the use of R1234-yf and ethanol as working fluids in a wickless heat pipe, with air flowing through the heat exchanger ducts. The hot air temperatures were set at 50°C, 55°C and 60°C, while the cold air temperature was fixed at 20°C. Both hot and cold air streams were pumped with Reynolds numbers ranging from 2583 to 20664. The wickless heat pipe was oriented vertically and filled with varying filling ratios of 20%, 40%, 60%, 80% and 100%. The results demonstrate that the wickless heat pipe - heat exchanger achieved the best thermal performance of 0.181 at a filling ratio of 60%, using ethanol as the working fluid and a Reynolds number of 10332. Additionally, a novel approach is proposed to predict the overall thermal performance of the wickless heat pipe - heat exchanger, and the predicted results show good agreement with the experimental findings
- 1 January 2023
- Published by Chaoyang University of Technology (IJASE) in International Journal of Applied Science and Engineering
- Vol. 20 (3) , 1-12
Open AccessOptimization of wickless heat pipe heat exchanger using R1234-yf and ethanol as working fluids
This experimental study investigates the use of R1234-yf and ethanol as working fluids in a wickless heat pipe, with air flowing through the heat exchanger ducts. The hot air temperatures were set at 50°C, 55°C and 60°C, while the cold air temperature was fixed at 20°C. Both hot and cold air streams were pumped with Reynolds numbers ranging from 2583 to 20664. The wickless heat pipe was oriented vertically and filled with varying filling ratios of 20%, 40%, 60%, 80% and 100%. The results demonstrate that the wickless heat pipe - heat exchanger achieved the best thermal performance of 0.181 at a filling ratio of 60%, using ethanol as the working fluid and a Reynolds number of 10332. Additionally, a novel approach is proposed to predict the overall thermal performance of the wickless heat pipe - heat exchanger, and the predicted results show good agreement with the experimental findings