Yuanrui Huang
Research Subjects
Yuanrui Huang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hongbin Liu
Centre for Artificial Intelligence and Robotics, Hong Kong Institute of Science Innovation, Chinese Academy of Sciences, Hong Kong, China
5 shared publications - Jian Hu
Beijing University of Technology
3 shared publications - Heng Wang
South China University of Technology
2 shared publications - Jian Chen
Centre for Artificial Intelligence and Robotics, Hong Kong Institute of Science Innovation, Chinese Academy of Sciences, Hong Kong, China
2 shared publications - Shuangyi Wang
Institute of Automation, Chinese Academy of Sciences
2 shared publications - Fan Zhang
School of Robotics, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu, China
1 shared publication
Latest Publications
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (1) , 124-135
HM-Array: A Novel Haptic Magnetism-Based Leader-Follower Platform for Minimally Invasive Robotic Surgery
Ensuring the safety and authenticity of haptic feed2 back is crucial in the domain of surgical operations, particularly in procedures like Natural Orifice Transluminal Endoscopic Surgery (NOTES) and Minimally Invasive Robotic Surgery (MIRS). To enhance the control efficiency of the robotic operating console, we propose a haptic magnetism-based array (HM7 Array). This system employs a solenoid array and a detection stylus to achieve controller localization without the need for additional sensors, while simultaneously generating haptic effects. The device effectively controls the surgical robot's pose through a localization-haptic combined loopback. The entire system is scheduled on a finite state machine (FSM), seamlessly fusing localization and haptic generation. Psychometric evaluations con14 ducted through user studies have demonstrated the device's pre15 cision and accuracy. Teleoperation experimental results further confirm its potential value in surgical treatments and broader medical haptic applications.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (1) , 124-135
HM-Array: A Novel Haptic Magnetism-Based Leader-Follower Platform for Minimally Invasive Robotic Surgery
Ensuring the safety and authenticity of haptic feed2 back is crucial in the domain of surgical operations, particularly in procedures like Natural Orifice Transluminal Endoscopic Surgery (NOTES) and Minimally Invasive Robotic Surgery (MIRS). To enhance the control efficiency of the robotic operating console, we propose a haptic magnetism-based array (HM7 Array). This system employs a solenoid array and a detection stylus to achieve controller localization without the need for additional sensors, while simultaneously generating haptic effects. The device effectively controls the surgical robot's pose through a localization-haptic combined loopback. The entire system is scheduled on a finite state machine (FSM), seamlessly fusing localization and haptic generation. Psychometric evaluations con14 ducted through user studies have demonstrated the device's pre15 cision and accuracy. Teleoperation experimental results further confirm its potential value in surgical treatments and broader medical haptic applications.
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (4) , 3956-3963
Design and Modeling of a Multi-DoF Magnetic Continuum Robot With Diverse Deformation Modes
Magnetically-actuated continuum robots (MCRs) have the potential to be miniaturized to submillimeter sizes. However, their limited deformation modes hinder their ability to navigate through narrow and tortuous lumens. In this paper, we introduce a novel 2-degrees of freedom (DoF) MCR with diverse deformation modes. To validate the concept, a 20mm-long MCR is fabricated. We also present an optimization algorithm to expand the MCR's workspace, relying on a deformation estimation algorithm that has been experimentally proven to have an error of less than 1.15mm on the fabricated prototype. The optimized MCR exhibits a 40% larger workspace compared to conventional MCRs. Additionally, we integrate the 2-DoF MCR with mechanical devices and propose a Jacobian-based control scheme for them. Experimental results confirm its capability for tip trajectory tracking tasks with an RMS error of 0.71mm and demonstrate its ability for obstacle avoidance. These innovations hold significant implications for the development of MCRs, paving the way toward more efficient interventional procedures.
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (4) , 3956-3963
Design and Modeling of a Multi-DoF Magnetic Continuum Robot With Diverse Deformation Modes
Magnetically-actuated continuum robots (MCRs) have the potential to be miniaturized to submillimeter sizes. However, their limited deformation modes hinder their ability to navigate through narrow and tortuous lumens. In this paper, we introduce a novel 2-degrees of freedom (DoF) MCR with diverse deformation modes. To validate the concept, a 20mm-long MCR is fabricated. We also present an optimization algorithm to expand the MCR's workspace, relying on a deformation estimation algorithm that has been experimentally proven to have an error of less than 1.15mm on the fabricated prototype. The optimized MCR exhibits a 40% larger workspace compared to conventional MCRs. Additionally, we integrate the 2-DoF MCR with mechanical devices and propose a Jacobian-based control scheme for them. Experimental results confirm its capability for tip trajectory tracking tasks with an RMS error of 0.71mm and demonstrate its ability for obstacle avoidance. These innovations hold significant implications for the development of MCRs, paving the way toward more efficient interventional procedures.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (3) , 2670-2677
Multi-Interface Strain Transfer Modeling for Flexible Endoscope Shape Sensing
Robot-assisted minimally invasive surgery (MIS) using flexible endoscopy has emerged as a groundbreaking technology for improving traditional surgical approaches. However, a major challenge in advancing this technology is the lack of shape sensing, which leads to inaccurate navigation and control of ultra-long flexible endoscopy within the narrow and tortuous lumen environment. The unique characteristics of flexible endoscopy, including large slenderness ratio, high bending angles, and non-symmetric, multi-channel configurations, pose significant challenges to accurate shape sensing. To address this challenge, we propose a novel shape-sensing scheme based on distributed fiber optic strain measurement, which incorporates a complete and applicable multi-interface strain transfer model adapted to large deformation and multiple sensing points. To validate the theoretical model, a shape sensor with a diameter of 2.84 mm and a length of 500 mm is fabricated. Both 2D and 3D shape sensing experiments are conducted on predefined templates, and the results highlight a significant improvement in the precision of sensor measurements through the utilization of the proposed model. Specifically, the 3D experiment results show a mean absolute error (MAE) of 5.38 mm for complex geometrical shapes and the proposed model reduces the MAE by approximately 52.9% compared to the unmodified case.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (3) , 2670-2677
Multi-Interface Strain Transfer Modeling for Flexible Endoscope Shape Sensing
Robot-assisted minimally invasive surgery (MIS) using flexible endoscopy has emerged as a groundbreaking technology for improving traditional surgical approaches. However, a major challenge in advancing this technology is the lack of shape sensing, which leads to inaccurate navigation and control of ultra-long flexible endoscopy within the narrow and tortuous lumen environment. The unique characteristics of flexible endoscopy, including large slenderness ratio, high bending angles, and non-symmetric, multi-channel configurations, pose significant challenges to accurate shape sensing. To address this challenge, we propose a novel shape-sensing scheme based on distributed fiber optic strain measurement, which incorporates a complete and applicable multi-interface strain transfer model adapted to large deformation and multiple sensing points. To validate the theoretical model, a shape sensor with a diameter of 2.84 mm and a length of 500 mm is fabricated. Both 2D and 3D shape sensing experiments are conducted on predefined templates, and the results highlight a significant improvement in the precision of sensor measurements through the utilization of the proposed model. Specifically, the 3D experiment results show a mean absolute error (MAE) of 5.38 mm for complex geometrical shapes and the proposed model reduces the MAE by approximately 52.9% compared to the unmodified case.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling and Compensation of Self-Twisting Angle for Shape Sensing in Flexible Bronchoscopy
This work presents a novel scheme for shape sensing, targeting the inherent characteristics and challenges of flexible bronchoscopes (FB) with a large slenderness ratio, low stiffness, asymmetrical multi-channel structures, and significant bending deformations. The approach analyzes the coupling issue between bending angles and self-twist angles in shape reconstruction and proposes a viable compensation model to enhance shape-sensing accuracy. Furthermore, experimental results conducted on a scaled human bronchial model demonstrate an average absolute error (MAE) of 2.28mm and a root mean square error (RMSE) of 1.23mm for the proposed scheme, validating the effectiveness and feasibility.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling and Compensation of Self-Twisting Angle for Shape Sensing in Flexible Bronchoscopy
This work presents a novel scheme for shape sensing, targeting the inherent characteristics and challenges of flexible bronchoscopes (FB) with a large slenderness ratio, low stiffness, asymmetrical multi-channel structures, and significant bending deformations. The approach analyzes the coupling issue between bending angles and self-twist angles in shape reconstruction and proposes a viable compensation model to enhance shape-sensing accuracy. Furthermore, experimental results conducted on a scaled human bronchial model demonstrate an average absolute error (MAE) of 2.28mm and a root mean square error (RMSE) of 1.23mm for the proposed scheme, validating the effectiveness and feasibility.
- 27 September 2023
- Published by Elsevier in Mechatronics
- Vol. 95
A hybrid force-magnetic control scheme for flexible medical device steering
- 27 September 2023
- Published by Elsevier in Mechatronics
- Vol. 95
A hybrid force-magnetic control scheme for flexible medical device steering