SYSemih Yılmaz

Semih Yılmaz

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Semih Yılmaz has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determination of Irbesartan in Pharmaceutical Preparations by Polarographic Methods

    by Bilal Yılmaz, Aytekin Korkmaz, Semih Yılmaz, Yücel Kadıoğlu

    In this study, the polarographic behavior of irbesartan was investigated using the cyclic polarographic method. A mercury drop electrode was used to quantify the peak currents in comparison to Ag/AgCl at 0.10 V/s. Additionally, quick and easy square wave and differential pulse polarographic methods were developed and validated to determine irbesartan in pharmaceutical preparations. For both methods, the calibration curves were linear at concentrations between 5 and 70 μg/mL. The precision was given by relative standard deviation and was less than 2.61%. Accuracy was given with relative error and did not exceed 1.24%. The suggested methods are extremely accurate and precise. No interference was found under the chosen experimental conditions. In pharmaceutical preparations, irbesartan had an average recovery of 99.8%. Therefore, the methods are applicable to the determination of irbesartan in pharmaceutical preparations.

  • Open Access

    Electrochemical Study of Clopidogrel and its Determination in Pharmaceutical Preparations Using Square Wave Voltammetry

    by Bilal Yılmaz, Semih Yılmaz

    In the present study, the electroanalytical behaviour of clopidogrel was investigated by cyclic voltammetry method. The procedure was based on clopidogrel being electrochemically oxidized at a platinum electrode in nonaqueous solutions. At 1.93 V, the oxidation peak was noted. It was discovered that clopidogrel's oxidation was diffusion-controlled. Additionally, a quick and easy SWV approach was developed and validated in this work to determine clopidogrel in pharmaceutical preparations. At concentrations between 5 and 50 µg/mL, the calibration curve was linear. The precision was given by relative standard deviation and was less than 2.73%. Accuracy was given with relative error and did not exceed 3.89%. In pharmaceutical preparations, clopidogrel had an average recovery of 100.1%. Under the chosen experimental conditions, no interference was found. The suggested method is extremely accurate and precise. Therefore, the method is applicable to the measurement of clopidogrel in pharmaceutical formulations.