Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shu Zhang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimized Cable-Armor Blocking for Metro Stray Current Mitigation in Urban Power Grids

    by Shu Zhang, Shengbao Zhang, Shixiang Wang, Hong Shen, Kangguan Ke, Chuang Wang

    Metro DC traction systems cause return current to leak from the running rails into the earth. This stray current intrudes into urban power grids through metallic paths such as cable armors, driving transformer DC bias that can cause core saturation, increased losses, vibration, and accelerated insulation aging. Conventional mitigation measures install blocking devices at transformer neutral points only after the current limit is exceeded; this single-point treatment protects the treated transformer but may redistribute stray current to neighboring substations, requiring repeated device installations. To overcome this limitation, this paper proposes a coordinated mitigation method for metro stray current in urban power grids based on cable armor path blocking. An equivalent nodal admittance model incorporating cable armor blocking is established to calculate transformer neutral-point currents following current redistribution. A constrained optimization model is formulated and solved by NSGA-II to jointly minimize the maximum neutral-point current and the number of blocking devices, and Monte Carlo sampling of train positions is used to determine the selection frequency of each candidate location across repeated optimization outcomes and identify priority installation locations. Simulation results show that, in a practical coupled metro–power grid case, the proposed method effectively suppresses transformer neutral-point currents throughout the network with fewer devices than conventional single-point neutral-point blocking under the examined operating conditions. Multi-scenario analysis further identifies cable armor paths that consistently have high placement priority across different train positions, supporting coordinated siting and phased deployment of blocking devices.

  • Open Access

    Fault Location Method for Continuous Transmission Lines of High-Speed Railway Based on Low-Voltage Measurements at Box-Type Substations

    by Jie Tang, Shu Zhang, Yuyin Zhao

    Precise fault localization for high-speed railway continuous transmission lines is indispensable for sustaining power supply reliability and mitigating power outages. This study presents a novel fault localization approach that uses low-voltage information obtained from box-type substations distributed along continuous transmission lines. The proposed scheme relies on the distribution features of the positive-to-negative sequence voltage ratio (rPNV) measured at the low-voltage terminals of box-type substations. Results reveal that the magnitude of rPNV gradually declines from the main substation to the fault location in the fault upstream area, while it stays nearly unchanged in the downstream section. Based on this feature, the faulted section is initially determined by means of the nearest neighbor clustering method. Subsequently, the precise fault location is calculated by solving equations that combine the sequence voltage ratio at the fault point with the measurements obtained from the main substation and box-type substations downstream of the fault. The proposed method requires only asynchronous low-voltage measurements, eliminates the need for fault impedance modeling, and is applicable to various asymmetric faults. Simulation tests under different fault types, fault resistances (up to 2000 Ω), noise conditions, and neutral grounding modes demonstrate that the method achieves high accuracy and robustness.

  • Open Access

    Generalized Lissajous Trajectory Image Learning for Multi-Load Series Arc Fault Detection in 220 V AC Systems Considering PV and Battery Storage

    by Wenhai Zhang, Rui Tang, Junjian Wu, Yiwei Chen, Chunlan Yang, Shu Zhang

    This paper proposes a novel AC side series arc fault (SAF) identification method based on Generalized Lissajous Trajectory (GLT) learning for low-voltage residential circuits. The method addresses challenges in detecting SAFs—characterized by high concealment, random occurrence, and limitations in existing protection devices—by leveraging the Hilbert transform to map current signals into 2D Generalized Lissajous Trajectories. These trajectories amplify key SAF features (e.g., zero-break distortion and random pulses). A ResNet50-based image recognition model achieves high-precision fault detection under specific load types, with a validation accuracy of up to 99.91% for linear loads and 98.93% for nonlinear loads. The algorithm operates within 1.6 ms, enabling real-time circuit breaker tripping. The proposed method achieves higher recognition accuracy with lower computational cost compared to other image-based methods. In this paper, an adjustable load signal modeling approach is proposed to visualize the current signal using GLT and complete the lightweight identification based on ResNet network, which provides new ideas and methods for series arc fault detection.


  • Open Access

    Two-Layer Optimization Strategy of Electric Vehicle and Air Conditioning Load Considering the Benefit of Peak-to-Valley Smoothing

    by Sichen Shi, Peiyi Wang, Zixuan Zheng, Shu Zhang

    To satisfy the interests of multiple agents and those of comprehensive indicators such as peak-to-valley differences and load fluctuations occurring on the network side, this paper presents a flexible load demand-side response optimization method that considers the benefits of peak-to-valley smoothing. First, load aggregation modelling of air conditioning and electric vehicles was conducted, and the complementarity of the power consumption behavior of different types of flexible loads was used to improve the responsiveness of the load aggregator. Second, considering demand-side responses and taking into account the interests of both supply and demand, the load fluctuation and peak-to-valley difference on the network side are reduced, and a flexible load double-layer optimization model incorporating the peak-to-valley smoothing benefit is established. Finally, the effectiveness of the proposed optimization model is verified by using the KKT condition and the big M method to evaluate this two-layer optimization problem as a single-layer optimization problem. Comparative examples show that the proposed two-layer optimization method can take advantage of the complementarity of air conditioning and electric vehicles to improve the income of load aggregators. Moreover, the proposed method can effectively reduce the load peak-to-valley difference and load fluctuation of the distribution network by introducing the peak-to-valley smoothing benefit model.


  • Open Access

    A Demand-Side Response Optimization Method for Flexible Loads Considering the Benefits of Peak-to-Valley Smoothing

    by Sichen Shi, Peiyi Wang, Zixuan Zheng, Shu Zhang

    To satisfy the interests of multiple agents and those of comprehensive indicators such as peak-to-valley differences and load fluctuations occurring on the network side, this paper presents a flexible load demand-side response optimization method that considers the benefits of peak-to-valley smoothing. First, load aggregation modelling of air conditioning and electric vehicles was conducted, and the complementarity of the power consumption behaviour of different types of flexible loads was used to improve the responsiveness of the load aggregator. Second, considering demand-side responses and taking into account the interests of both supply and demand, the load fluctuation and peak-to-valley difference on the network side are reduced, and a flexible load double-layer optimization model incorporating the peak-to-valley smoothing benefit is established. Finally, the effectiveness of the proposed optimization model is verified by using the KKT condition and the big M method to evaluate this two-layer optimization problem as a single-layer optimization problem. Comparative examples demonstrate that the proposed two-layer optimization method can improve the revenue of the distribution network operators and the load aggregators by using the complementary nature of the load response characteristics of electric vehicles and air conditioners. Moreover, the proposed method can effectively reduce the load peak-to-valley difference and load fluctuation of the distribution network by introducing the peak-to-valley smoothing benefit model.

  • Adaptive Harmonic Virtual Impedance Control for Improving Voltage Quality of Microgrids

    by Yang Wang, Xiang Zhou, Junmiao Tang, Xianyong Xiao, Shu Zhang, Jiandong Si

    The effects of nonlinear loads on voltage quality represent an emerging concern for islanded microgrids. Existing research works have mainly focused on harmonic power sharing among multiple inverters, which ignores the diversity of different inverters to mitigate harmonics from nonlinear loads. As a result, the voltage quality of microgrids cannot be effectively improved. To address this issue, this study proposes an adaptive harmonic virtual impedance (HVI) control for improving voltage quality of microgrids. Based on the premise that no inverter is overloaded, the main objective of the proposed control is to maximize harmonic power absorption by shaping the lowest output impedances of inverters. To achieve this, the proposed control is utilized to adjust the HVI of each inverter based on its operation conditions. In addition, the evaluation based on Monte Carlo harmonic power flow is designed to assess the performance of the proposed control in practice. Finally, comparative studies and control-in-the-loop experiments are conducted.


  • Open Access

    Three-stage day-ahead scheduling strategy for regional thermostatically controlled load aggregators

    by Dejin Fan, Shu Zhang, He Huang, Liping Zhou, Yang Wang, Xianyong Xiao

    Thermostatically controlled loads (TCLs) are regarded as having potential to participate in power grid regulation. This paper proposes a scheduling strategy with three-stage optimization for regional aggregators jointly participating in day-ahead scheduling to support demand response. The first stage is on the profit of aggregators and peak load of the grid. The line loss and voltage deviation of regulation are considered to ensure stable operation of the power grid at the second stage, which guarantees the fairness of the regulation and the comfort of users. A single temperature adjustment strategy is used to control TCLs to maximize the response potential in the third stage. Finally, digital simulation based on the IEEE 33-bus distribution network system proves that the proposed three-stage scheduling strategy can keep the voltage deviation within ± 5% in different situations. In addition, the Gini coefficient of distribution increases by 20% and the predicted percentage of dissatisfied is 48% lower than those without distribution.