HKHyoung Tae Kim

Hyoung Tae Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hyoung Tae Kim has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy of Large Language Models for Screening of Systematic Reviews on Periprosthetic Joint Infection

    by Woojin Shin, Jaeyoung Hong, Sunwoo Lee, Seongchan Park, Hyoungtae Kim, Suenghwan Jo

    Background: Periprosthetic joint infection (PJI) remains a devastating complication following arthroplasty. Systematic reviews of PJI provide essential evidence to inform clinical practice; however, the screening process remains labor-intensive. Recent advancements in large language models (LLMs) offer potential for automating literature screening, though evaluation of current generation models is needed. Methods: This validation study evaluated GPT-5, GPT-5 Pro, and Gemini 2.5 Pro in replicating the title/abstract and full-text screening stages of a published systematic review on intraosseous versus intravenous antibiotic prophylaxis in total joint arthroplasty. Title/abstract screening was performed on 165 articles, followed by a full-text eligibility assessment of 26 articles. Accuracy, sensitivity, specificity, and Cohen’s kappa (κ) were calculated against human screening decisions as the gold standard. Results: In title/abstract screening, GPT-5 Pro achieved the highest accuracy (92.1–92.7%) and specificity (98.6–99.3%), while GPT-5 demonstrated the highest sensitivity (84.6–96.1%). In full-text screening, Gemini 2.5 Pro showed the most consistent performance across repeated evaluations (κ = 0.839 in both trials), whereas GPT-5 Pro exhibited marked intra-model variability (κ = 0.399 to 0.920). Conclusions: Current-generation LLMs achieve near-human accuracy in systematic review screening for PJI research, though substantial intra-model variability underscores the continued need for human oversight in systematic review workflows.

  • Open Access

    Efficacy of Injectable Calcium Composite Bone Substitute Augmentation for Osteoporotic Intertrochanteric Fractures: A Prospective, Non-Randomized Controlled Study

    by Chae Hun Lee, Hyoung Tae Kim, Hong Moon Sohn, Gwui Cheol Kim, Eun Ju Jin, Suenghwan Jo

    Background/Objectives: Femoral intertrochanteric fractures (ITFs) in older adults are associated with a substantial risk of mechanical failure after fixation, which can lead to persistent pain, delayed mobilization, and increased mortality. Injectable calcium composite bone substitute (ICCBS) augmentation has been proposed as a strategy to enhance construct stability and promote bone healing, but clinical evidence remains limited. The purpose of this study was to evaluate the efficacy of ICCBS in the management of osteoporotic ITFs. Methods: We conducted a multicenter, prospective, non-randomized controlled study of patients undergoing surgical fixation for osteoporotic ITFs using proximal femoral nails. Patients who consented to augmentation received ICCBS, while the control group underwent standard fixation alone. Demographic and injury-related variables were documented, and outcome data were prospectively collected. The primary outcome was time to radiographic bone union, while secondary outcomes included functional recovery (pain and ambulatory status) and complications, including fixation failure. Results: The mean time to radiographic bone union did not differ significantly between groups (p = 0.28). However, patients receiving ICCBS augmentation reported significantly lower postoperative pain scores up to 6 weeks and demonstrated reduced lag screw sliding and varus collapse at the time of bone union. There were no significant differences in complication rates, fixation failure, or ambulatory status at last follow-up between the two groups. Conclusions: ICCBS augmentation may improve early postoperative pain, construct stability, and functional recovery in patients with osteoporotic ITFs, although its effect on fracture healing and long-term outcomes remains uncertain. Further high-quality randomized trials are warranted to confirm these findings.

  • Open Access

    Efficacy and Safety of Intraosseous Versus Intravenous Antibiotic in Primary and Revision Total Joint Arthroplasty: A Systematic Review and Meta-Analysis

    by Sunwoo Lee, Jiyun Kang, Yonggyun Moon, Jaeyoung Hong, Hyoungtae Kim, Suenghwan Jo

    Background and Objectives: Periprosthetic joint infection (PJI) is one of the most serious complications following total joint arthroplasty (TJA), leading to poor functional outcomes and increased healthcare burden. Intraosseous (IO) regional antibiotic prophylaxis has emerged as a promising method for infection prevention, offering potential advantages over conventional intravenous (IV) systemic administration. This study aimed to systematically evaluate the clinical evidence on the efficacy and safety of IO prophylaxis in TJA. Materials and Methods: A comprehensive literature search was conducted in PubMed, Embase, Scopus, Web of Science, and the Cochrane Library up to 23 June 2025. Eligible studies included randomized controlled trials and observational studies reporting outcomes of IO antibiotic administration in TJA. Primary endpoints were systemic and local antibiotic concentrations (bone and fat tissue), the incidence of PJI, and complication profiles. Risk of bias was assessed using the ROB-2 and ROBINS-I tools, and meta-analyses were conducted using RevMan v 7.2.0. Results: Fifteen studies (eight RCTs, one prospective study, and six retrospective studies) were included for qualitative synthesis, of which ten were included in the meta-analysis. As compared with IV, IO administration resulted in significantly higher local antibiotic concentrations in bone (MD: 15.52 μg/g; 95% CI: 8.60–22.45; p < 0.0001) and fat tissue (MD: 18.15 μg/g; 95% CI: 12.86–23.45; p < 0.0001). IO prophylaxis was associated with a significantly lower PJI rate (OR: 0.26; 95% CI: 0.12–0.57; p = 0.008) without a significant difference in the incidence of complications (p = 0.66). Conclusions: IO antibiotic prophylaxis is an effective and safe strategy for infection prevention in total joint arthroplasty. By achieving superior local antibiotic concentrations and reducing PJI rates without increasing complications, this approach holds promise for broader clinical application.


  • Open Access

    Biofilm Growth on Different Materials Used in Contemporary Femoral Head Prosthesis: An In Vitro Study

    by Yonggyun Moon, Jaeyoung Hong, Sookyung Choi, Hyoungtae Kim, Hong Moon Sohn, Suenghwan Jo

    Background/Objectives: Periprosthetic joint infection (PJI) primarily results from bacterial biofilms adhering to prosthetic surfaces, making treatment challenging without prosthesis removal. This in vitro study aims to investigate whether the materials used in contemporary femoral head prosthesis influences bacterial biofilm development. Methods: Femoral head prostheses made of three different materials—cobalt–chrome, oxinium, and ceramic—were inoculated with either Staphylococcus aureus or Pseudomonas aeruginosa in separate experiments, with each pathogen tested independently. The samples were cultured under shaking conditions at 37 °C for 96 h to promote biofilm formation. Scanning electron microscopy (SEM) was used to confirm the presence of biofilms, and adherent biofilms were quantified by counting colony-forming units (CFUs) after sonication. Additionally, crystal violet staining was performed to assess biofilm distribution on the femoral head surfaces. Statistical analyses compared CFU counts across the different materials. Results: The mean CFU counts for S. aureus were 7.6 × 105 ± 9.7 × 104 for cobalt–chrome, 6.9 × 105 ± 3.6 × 105 for oxinium, and 1.1 × 106 ± 3.0 × 105 for ceramic femoral head prostheses. For P. aeruginosa, the CFU counts were 2.3 × 106 ± 7.2 × 105, 3.7 × 106 ± 2.5 × 106, and 2.2 × 106 ± 8.9 × 105, respectively. Regardless of the bacterial strain, differences among the three materials were within one log range, and no statistical significance was observed. While biofilms were confirmed using SEM, limited adherence was observed on the bearing surface, with the biofilm predominantly localized in the taper hole. Conclusions: The findings suggest that the material used in contemporary femoral head prostheses has minimal impact on bacterial biofilm formation. Surgeons’ choice of femoral head prosthesis material should base their material selection on factors other than PJI prevention.


  • Open Access

    Sandwiched Strut Allografts with Stem Retention to Treat Fragile Periprosthetic Femoral Fractures: A Case Report

    by Hyoung Tae Kim, Hyun Jun Lee, Suenghwan Jo

    Managing periprosthetic femoral fractures is challenging, particularly in osteoporotic patients with fragile bones. Revision with a long stem is commonly considered but may fail to provide adequate fixation and stability in fragile bones. A novel approach using sandwiched strut allografts and controlled bone crushing with robust cable fixation can offer mechanical support and provide secondary stability to the loosened femoral stem and can be considered a treatment option for low-demand patients. A 73-year-old female with 23 years of hemodialysis experienced pain and instability in her right thigh following a slip. She had extremely low bone mineral density, and radiographs revealed a periprosthetic femoral fracture with a loosened femoral prosthesis, classified as Vancouver type B3. The patient underwent surgical fixation using a long anatomical plate augmented with dual strut allografts sandwiched anterior and posterior femur. Robust cable fixation was performed to partially crush the native cortical bone against the stem to enhance stability. Postoperative imaging at 18 months confirmed successful bone union and implant stability, and the patient regained preoperative functional capacity without pain. This case demonstrates that partially crushing native bone with dual strut allografts may provide stability to the loosened femoral stem and can be an effective alternative to long-stem revision surgery for patients with highly fragile bones. This approach may provide immediate mechanical stability and can be a potential treatment option for managing fragile periprosthetic femoral fractures.


  • Open Access

    Biomechanical Investigation to Establish Stable Fixation Strategies for Distal Tibial Fractures in Various Situations: Finite Element Analysis Studies

    by Sung Hun Yang, Jun Young Lee, Gu-Hee Jung, Hyoung Tae Kim, Ba Woo Ko

    양성훈, et al. J Korean Fract Soc. 2024 Apr;37(2):71-81. https://doi.org/10.12671/jkfs.2024.37.2.71


  • Open Access

    Treatment of Soft Tissue Defects after Minimally Invasive Plate Osteosynthesis in Fractures of the Distal Tibia: Clinical Results after Reverse Sural Artery Flap

    by Jun Young Lee, Hyo Jun Lee, Sung Hoon Yang, Je Hong Ryu, Hyoung Tae Kim, Byung Ho Lee, Sung Hwan Kim, Ho Sung Kim, Young Koo Lee

    Introduction: Distal tibial fractures make up approximately 3% to 10% of all tibial fractures or about 1% of lower extremity fractures. MIPO is an appropriate procedure and method to achieve stable metal plate fixation and osseointegration by minimizing soft tissue damage and vascular integrity at the fracture site. MIPO to the medial tibia during distal tibial fractures induces skin irritation due to the thickness of the metal plate, which causes discomfort and pain on the medial side of the distal leg, and if severe, complications such as infection and skin defect may occur. The reverse sural flap is a well-researched approach for covering defects in the lower third of the leg, ankle, and foot. Materials and Methods: Among 151 patients with distal tibia fractures who underwent minimally invasive metal plate fixation, soft tissue was injured due to postoperative complications. We treated 13 cases with necrosis and exposed metal plates by retrograde nasogastric artery flap surgery. For these patients, we collected obligatory patient records, radiological data, and wound photographs of the treatment results and complications of reconstructive surgery. Results: In all the cases, flap survival was confirmed at the final outpatient follow-up. The exposed area of the metal plate was well coated, and there was no plate failure due to complete necrosis. Three out of four women complained of aesthetic dissatisfaction because the volume of the tunnel through which the skin mirror passed and the skin plate itself were thick. In two cases, defatting was performed to reduce the thickness of the plate while removing the metal plate. Conclusions: Metal plate exposure after distal tibial fractures have been treated with minimally invasive metal plate fusion and can be successfully treated with retrograde nasogastric artery flaps, and several surgical techniques are used during flap surgery.