Mohammed Ed-Dhahraouy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammed Ed-Dhahraouy has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Manal Ezzahmouly
Chouaib Doukkali University
3 shared publications - Zineb Hatim
Chouaib Doukkali University
2 shared publications A. ElAlbani
IC2MP, UMR CNRS 7285, Poitiers University, Poitiers, France
1 shared publicationA. Elmoutaouakkil
Research Laboratory in Optimization, Emerging Systems, Networks and Imaging, LAROSERI, Computer Science Department, ChouaïbDoukkali University, Eljadida, Morocco
1 shared publication- Abdelaziz Elouahli
Chouaib Doukkali University
1 shared publication - Abdelmajid El Moutaouakkil
Chouaib Doukkali University
1 shared publication
Latest Publications
- Open Access
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 3161-3169
The contribution of image processing in the evaluation of guided bone regeneration
One of the most ambitious goals of modern bone surgery is to predict the shape of the bone defect, monitor the progress of bone regeneration, and assess the quantity and quality of newly formed bone. Calcium phosphate biomaterials such as hydroxyapatite and tricalcium phosphate are commonly used as bone substitutes in maxillofacial and dental surgery. The objective of this work is to use cone-beam computed tomography (CBCT) and image processing to assess the spatial (architectural) layout, rate of bone generation and osseointegration of implanted commercial granules (PAH 40%, β-TCP 60%, size 0.5 to 1 mm) in the bone defect generated after tooth extraction. CBCT measurements were performed at 48 hours and 12 months. The analysis of 3D images and the application of appropriate morphological mathematical operations allowed us to evaluate the volume of the cavity to be filled, the volume occupied by the granules and the volume of porosity generated by the random stacking of the granules. The result shows that the bone generation rate reaches a value of 89% after one year of implantation. This study shows that by using 3D image processing techniques CBCT, the same results as classical anatomical and histological studies can be obtained.
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 3161-3169
Open AccessThe contribution of image processing in the evaluation of guided bone regeneration
One of the most ambitious goals of modern bone surgery is to predict the shape of the bone defect, monitor the progress of bone regeneration, and assess the quantity and quality of newly formed bone. Calcium phosphate biomaterials such as hydroxyapatite and tricalcium phosphate are commonly used as bone substitutes in maxillofacial and dental surgery. The objective of this work is to use cone-beam computed tomography (CBCT) and image processing to assess the spatial (architectural) layout, rate of bone generation and osseointegration of implanted commercial granules (PAH 40%, β-TCP 60%, size 0.5 to 1 mm) in the bone defect generated after tooth extraction. CBCT measurements were performed at 48 hours and 12 months. The analysis of 3D images and the application of appropriate morphological mathematical operations allowed us to evaluate the volume of the cavity to be filled, the volume occupied by the granules and the volume of porosity generated by the random stacking of the granules. The result shows that the bone generation rate reaches a value of 89% after one year of implantation. This study shows that by using 3D image processing techniques CBCT, the same results as classical anatomical and histological studies can be obtained.
- Open Access
- 1 August 2023
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 19 (10) , 169-176
Threshold-Based Segmentation for Landmark Detection Using CBCT Images
The aim of this study is to examine the influence of threshold-based segmentation on the mean error of automatic landmark detection in 3D CBCT images. A GUI was developed for radiologists, allowing manual landmark identification and visualization of CBCT images. After a threshold-based segmentation, a semi-automatic algorithm for landmark detection was designed using the anatomic definition of each landmark. A step of 50 Hounsfield units was used for threshold variation to assess the detection error. 5 CBCT images were used to validate the proposed approach. The measurement of error detection for one patient was influenced by the threshold variation. For this patient, the error changed from 1.49 mm to 10.32 mm at a low threshold value, while for another patient, the error changed from 1.96 mm to 12.28 mm at high a threshold value. In a CBCT scanner, the choice of threshold value for segmentation can be an important factor in causing error in measurements.
- 1 August 2023
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 19 (10) , 169-176
Open AccessThreshold-Based Segmentation for Landmark Detection Using CBCT Images
The aim of this study is to examine the influence of threshold-based segmentation on the mean error of automatic landmark detection in 3D CBCT images. A GUI was developed for radiologists, allowing manual landmark identification and visualization of CBCT images. After a threshold-based segmentation, a semi-automatic algorithm for landmark detection was designed using the anatomic definition of each landmark. A step of 50 Hounsfield units was used for threshold variation to assess the detection error. 5 CBCT images were used to validate the proposed approach. The measurement of error detection for one patient was influenced by the threshold variation. For this patient, the error changed from 1.49 mm to 10.32 mm at a low threshold value, while for another patient, the error changed from 1.96 mm to 12.28 mm at high a threshold value. In a CBCT scanner, the choice of threshold value for segmentation can be an important factor in causing error in measurements.