Guiying Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guiying Xu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Fan Yang
College of Hydraulic Science and Engineering Yangzhou University, Yangzhou, 225009, China
3 shared publications - Dongjin Jiang1 shared publication
Fangping Tang
1 shared publicationHaoru Zhao
1 shared publicationJiale Ding
1 shared publicationSihai Li
Shandong Survey and Design Institute of Water Conservancy Co., Ltd. 1 , Jinan 250013, China
1 shared publication
Latest Publications
- 1 June 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (6)
Newton–Raphson-based optimizer guided feature mode decomposition and Hilbert transform for pressure pulsation analysis in a tubular pump
To address the challenge of extracting dynamic features from nonlinear and non-stationary pressure pulsation signals (PPSs) in tubular pumps with blade attachments, while overcoming issues often associated with traditional PPS processing methods, this study establishes a co-analytical algorithm by integrating Newton–Raphson-based optimizer guided feature mode decomposition and Hilbert transform (HT). The principal conclusions derived from this study can be summarized as follows: under high blade attachment area ratios (BAARs), the disturbance effect of the blade attachments on the flow pattern increases at Span = 0.50 and 0.95 of the impeller blades, and the surface velocity of blade fluctuates obviously at these positions. At the monitoring points near the hub and the middle of the impeller outlet, the PPSs exhibit sudden lower pressure coefficients over time, while the PPSs of the monitoring point closer to the rim side remain relatively stable. Under high BAARs, the number of occurrences of the maximum amplitude in the HT spectrum at the same monitoring point also increases. In addition, the monitoring point at the middle of the impeller outlet has the highest average of the standard deviation of pressure coefficient, reaching 0.0344.
- 1 June 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (6)
Newton–Raphson-based optimizer guided feature mode decomposition and Hilbert transform for pressure pulsation analysis in a tubular pump
To address the challenge of extracting dynamic features from nonlinear and non-stationary pressure pulsation signals (PPSs) in tubular pumps with blade attachments, while overcoming issues often associated with traditional PPS processing methods, this study establishes a co-analytical algorithm by integrating Newton–Raphson-based optimizer guided feature mode decomposition and Hilbert transform (HT). The principal conclusions derived from this study can be summarized as follows: under high blade attachment area ratios (BAARs), the disturbance effect of the blade attachments on the flow pattern increases at Span = 0.50 and 0.95 of the impeller blades, and the surface velocity of blade fluctuates obviously at these positions. At the monitoring points near the hub and the middle of the impeller outlet, the PPSs exhibit sudden lower pressure coefficients over time, while the PPSs of the monitoring point closer to the rim side remain relatively stable. Under high BAARs, the number of occurrences of the maximum amplitude in the HT spectrum at the same monitoring point also increases. In addition, the monitoring point at the middle of the impeller outlet has the highest average of the standard deviation of pressure coefficient, reaching 0.0344.
- Open Access
- 1 July 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (7)
Numerical analysis of pressure fluctuation characteristics of axial flow pump device of edge pump unit in multi-unit pumping station
Asymmetric layout gate station projects are prevalent in gate station engineering. When multiple pump units operate within such projects, the inflow patterns of the pump devices at different stations exhibit significant variations. Notably, edge pump units often display adverse operating characteristics, including vibration. This study aims to elucidate the hydraulic behavior of edge pump units in asymmetric layout gate station projects using numerical simulation methods. We validate the reliability of our numerical calculations through physical model tests. Specifically, we investigate the flow pressure pulsation characteristics of the axial flow pump device within the edge pump unit under various switching schemes employed in the gate station project. The results show that pressure fluctuations in axial flow pump devices exhibit distinct time-frequency characteristics based on different flow rates. An increase in flow rate results in a sharp rise in pressure fluctuation amplitudes within the axial flow pump device of the edge pump unit. During symmetric operation, the peak pressure fluctuations of the axial flow pump device are significantly smaller than those observed during asymmetric operation. This suggests that the edge pump unit operates more stably and experiences fewer pressure fluctuations under symmetric conditions. Optimizing the operation of edge pump units ensures stability and prolongs the service life of gate station projects.
- 1 July 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (7)
Open AccessNumerical analysis of pressure fluctuation characteristics of axial flow pump device of edge pump unit in multi-unit pumping station
Asymmetric layout gate station projects are prevalent in gate station engineering. When multiple pump units operate within such projects, the inflow patterns of the pump devices at different stations exhibit significant variations. Notably, edge pump units often display adverse operating characteristics, including vibration. This study aims to elucidate the hydraulic behavior of edge pump units in asymmetric layout gate station projects using numerical simulation methods. We validate the reliability of our numerical calculations through physical model tests. Specifically, we investigate the flow pressure pulsation characteristics of the axial flow pump device within the edge pump unit under various switching schemes employed in the gate station project. The results show that pressure fluctuations in axial flow pump devices exhibit distinct time-frequency characteristics based on different flow rates. An increase in flow rate results in a sharp rise in pressure fluctuation amplitudes within the axial flow pump device of the edge pump unit. During symmetric operation, the peak pressure fluctuations of the axial flow pump device are significantly smaller than those observed during asymmetric operation. This suggests that the edge pump unit operates more stably and experiences fewer pressure fluctuations under symmetric conditions. Optimizing the operation of edge pump units ensures stability and prolongs the service life of gate station projects.
- 1 September 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (9)
Cross influence of rotational speed and flow rate on pressure pulsation and hydraulic noise of an axial-flow pump
Axial-flow pumps may experience significant pressure pulsation and high hydraulic noise when deviating from design conditions, and this article investigates the cross influence of rotational speed and flow rate on inlet pressure pulsation and hydraulic noise of an axial-flow pump based on coherence theory through physical model experiments. The energy amplitude of pressure pulsation is directly proportional to rotational speed and inversely proportional to flow rate, as rotational speed increases, the energy distribution of the blade passage frequency (fBPF) within different frequency bands of pressure pulsation improves. Pressure pulsation and the overall natural frequency of the pump device work together to define the primary and secondary frequencies of the sound pressure level, as rotational speed increases, these frequencies eventually move toward 2fBPF, and the coherence coefficient at frequencies of fBPF and 2fBPF is above 0.9. To reduce hydraulic noise, both pressure pulsation and natural frequency should be given sufficient attention.
- 1 September 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (9)
Cross influence of rotational speed and flow rate on pressure pulsation and hydraulic noise of an axial-flow pump
Axial-flow pumps may experience significant pressure pulsation and high hydraulic noise when deviating from design conditions, and this article investigates the cross influence of rotational speed and flow rate on inlet pressure pulsation and hydraulic noise of an axial-flow pump based on coherence theory through physical model experiments. The energy amplitude of pressure pulsation is directly proportional to rotational speed and inversely proportional to flow rate, as rotational speed increases, the energy distribution of the blade passage frequency (fBPF) within different frequency bands of pressure pulsation improves. Pressure pulsation and the overall natural frequency of the pump device work together to define the primary and secondary frequencies of the sound pressure level, as rotational speed increases, these frequencies eventually move toward 2fBPF, and the coherence coefficient at frequencies of fBPF and 2fBPF is above 0.9. To reduce hydraulic noise, both pressure pulsation and natural frequency should be given sufficient attention.