Prabhat Kumar Vidyarthi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Prabhat Kumar Vidyarthi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Ashiwani Kumar
5 shared publicationsAaryan Kumar
National Institute of Technology Patna, patna, Patna, Bihar, 800005, INDIA
1 shared publicationAnkita Kumari
National Institute of Technology Patna, patna, Patna, Bihar, 800005, INDIA
1 shared publication- Ashiwani Kumar
Department of Electrical Engineering, NIT Patna, Patna, India
1 shared publication
Latest Publications
- 3 June 2026
- Published by Springer Nature
- p. 51-62
Modelling of Multi-area Deregulated LFC Microgrid Based on Renewable Energy Sources
- 3 June 2026
- Published by Springer Nature
- p. 51-62
Modelling of Multi-area Deregulated LFC Microgrid Based on Renewable Energy Sources
- 15 February 2026
- Published by Springer Nature
- p. 61-73
Designing of Two-Area Deregulated Fuzzy Based Microgrid Penetration of Renewable Energy Sources
- 15 February 2026
- Published by Springer Nature
- p. 61-73
Designing of Two-Area Deregulated Fuzzy Based Microgrid Penetration of Renewable Energy Sources
- Open Access
- 29 April 2024
- Published by IOP Publishing in Engineering Research Express
- Vol. 6 (2) , 025320
Renewable sources with virtual inertia penetration in multi area interconnected AGC using a modified MPC controller
The challenge of controlling frequency deviation becomes more difficult as the complexity of a power plant increases. The robustness of the controller has a major impact on the stability of a complex power system (CPS). Due to the hybridization of CPS basic Automatic Generation Control (AGC) controllers (PID, FOPID, and TID), they are insufficient to give optimal performance to a plant. This requires a robust controller. So, a modified MPC controller has been proposed and evaluated by comparing it with several existing controllers, which gives optimal performance in terms of overshoot, undershoot, and settling time and improves its performance approximately 45%. This research discusses a combined AGC model and control for a three-area CPS, where each producing area consists of a thermal plant, a Diesel power plant, and a Solar Thermal Power Plant (STPP). The results of the modified MPC are superior to those of the basic controller compared to several existing controllers. An improved version of Sea-horse Optimization (SHO) has been proposed to optimize the different controller settings. The superiority of the SHO is shown by a comparison with some well-known, current meta-heuristic methods. The higher penetration levels of renewable energy sources (RESs) reduced system inertia which further deteriorate frequency response in CPS. To overcome these challenges, virtual inertia (VI) has been implemented with MPC. VI is applied to improve the performance of the AGC of the interconnected CPS along with emphasizing the nature of intermittent RESs of PV and wind energy. The thorough study findings provide compelling evidence for the effectiveness and efficiency of the recommended control strategies and also point to the possibility of applying them in actual power systems to improve stability and performance.
- 29 April 2024
- Published by IOP Publishing in Engineering Research Express
- Vol. 6 (2) , 025320
Open AccessRenewable sources with virtual inertia penetration in multi area interconnected AGC using a modified MPC controller
The challenge of controlling frequency deviation becomes more difficult as the complexity of a power plant increases. The robustness of the controller has a major impact on the stability of a complex power system (CPS). Due to the hybridization of CPS basic Automatic Generation Control (AGC) controllers (PID, FOPID, and TID), they are insufficient to give optimal performance to a plant. This requires a robust controller. So, a modified MPC controller has been proposed and evaluated by comparing it with several existing controllers, which gives optimal performance in terms of overshoot, undershoot, and settling time and improves its performance approximately 45%. This research discusses a combined AGC model and control for a three-area CPS, where each producing area consists of a thermal plant, a Diesel power plant, and a Solar Thermal Power Plant (STPP). The results of the modified MPC are superior to those of the basic controller compared to several existing controllers. An improved version of Sea-horse Optimization (SHO) has been proposed to optimize the different controller settings. The superiority of the SHO is shown by a comparison with some well-known, current meta-heuristic methods. The higher penetration levels of renewable energy sources (RESs) reduced system inertia which further deteriorate frequency response in CPS. To overcome these challenges, virtual inertia (VI) has been implemented with MPC. VI is applied to improve the performance of the AGC of the interconnected CPS along with emphasizing the nature of intermittent RESs of PV and wind energy. The thorough study findings provide compelling evidence for the effectiveness and efficiency of the recommended control strategies and also point to the possibility of applying them in actual power systems to improve stability and performance.
- 21 April 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (6) , 6731-6747
A cascaded tilt MPC controller for AGC in multi-area interconnected HPS with penetration of RESs and virtual inertia
- 21 April 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (6) , 6731-6747
A cascaded tilt MPC controller for AGC in multi-area interconnected HPS with penetration of RESs and virtual inertia
- 19 March 2024
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 45 (4) , 1750-1773
Enhancing frequency regulation in multi‐area interconnected MPS with virtual inertia using MPC + PIDN controller
The challenge of controlling frequency deviation becomes more difficult as the complexity of a power network increases. The robustness of the controller has a major impact on the stability of a Modern Power system (MPS). Due to the hybridization of MPS basic AGC controllers (PID, FOPID, and TID) are insufficient to give optimal performance of a plant. This requires a robust controller. So, a novel MPC + PIDN controller has been proposed and evaluated by comparing it with several existing controllers, which gives optimal performance in terms of overshoot, undershoot, and settling time. A new modified Opposition‐based Sea‐horse Optimization (OSHO) method has been suggested to optimize the various controller settings. To demonstrate the OSHO's superiority, it is compared with a few popular, existing meta‐heuristic optimizations. The higher penetration levels of RESs reduced system inertia which further deteriorate frequency response in MPS. To overcome these challenges virtual inertia (VI) is implemented with MPC. VI is applied to improve the performance of the AGC of the interconnected MPS along with emphasizing the nature of intermittent renewable energy sources (RESs) of PV and wind energy. To determine the reliability and flexibility of the proposed controller, analysis has been done under a different situation, including step, random disturbances, and modified IEEE‐39 bus. Finally, the stability analysis is performed on a bode plot and the proposed results are compared with previously published literature. The extensive study demonstrates strong evidence that the suggested control approach is efficient and effective.
- 19 March 2024
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 45 (4) , 1750-1773
Enhancing frequency regulation in multi‐area interconnected MPS with virtual inertia using MPC + PIDN controller
The challenge of controlling frequency deviation becomes more difficult as the complexity of a power network increases. The robustness of the controller has a major impact on the stability of a Modern Power system (MPS). Due to the hybridization of MPS basic AGC controllers (PID, FOPID, and TID) are insufficient to give optimal performance of a plant. This requires a robust controller. So, a novel MPC + PIDN controller has been proposed and evaluated by comparing it with several existing controllers, which gives optimal performance in terms of overshoot, undershoot, and settling time. A new modified Opposition‐based Sea‐horse Optimization (OSHO) method has been suggested to optimize the various controller settings. To demonstrate the OSHO's superiority, it is compared with a few popular, existing meta‐heuristic optimizations. The higher penetration levels of RESs reduced system inertia which further deteriorate frequency response in MPS. To overcome these challenges virtual inertia (VI) is implemented with MPC. VI is applied to improve the performance of the AGC of the interconnected MPS along with emphasizing the nature of intermittent renewable energy sources (RESs) of PV and wind energy. To determine the reliability and flexibility of the proposed controller, analysis has been done under a different situation, including step, random disturbances, and modified IEEE‐39 bus. Finally, the stability analysis is performed on a bode plot and the proposed results are compared with previously published literature. The extensive study demonstrates strong evidence that the suggested control approach is efficient and effective.
- 15 September 2023
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 45 (1) , 185-207
A modified tilt controller for AGC in hybrid power system integrating forecasting of renewable energy sources
This article emphasizes the intermittent characteristics of renewable energy sources (RESs) and explores the role of forecasting in improving the performance of the automatic generation control (AGC) mechanism of the interconnected power system. Due to hybridization of power system basic AGC controller (PID, TID, and ID‐T) are insufficient to stabilized the system parameters. So, a new type of fractional order integral tilted derivative controller (FIDN‐T) has been proposed, which give better performance in terms of settling time, undershoot and overshoot in case of RESs with real data forecasting also. FIDN‐T has been compared with some existing controller which give the results better than basic controller. In order to optimize the different parameters of the proposed controller, a new modified Opposition‐based Sea‐horse Optimization (OSHO) algorithm has been proposed. The OSHO is compared with a few existing, well‐known meta‐heuristic algorithms to show its superiority. The analysis has been conducted under different operating conditions, including step and random disturbances as well as the IEEE‐39 bus, to verify the robustness as well as adaptability of the suggested controller. The comprehensive results of the studies provide strong evidence in support of the effectiveness and efficacy of the suggested control methods and suggest that it has the potential to be implemented in real‐world power systems for improved performance and stability.
- 15 September 2023
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 45 (1) , 185-207
A modified tilt controller for AGC in hybrid power system integrating forecasting of renewable energy sources
This article emphasizes the intermittent characteristics of renewable energy sources (RESs) and explores the role of forecasting in improving the performance of the automatic generation control (AGC) mechanism of the interconnected power system. Due to hybridization of power system basic AGC controller (PID, TID, and ID‐T) are insufficient to stabilized the system parameters. So, a new type of fractional order integral tilted derivative controller (FIDN‐T) has been proposed, which give better performance in terms of settling time, undershoot and overshoot in case of RESs with real data forecasting also. FIDN‐T has been compared with some existing controller which give the results better than basic controller. In order to optimize the different parameters of the proposed controller, a new modified Opposition‐based Sea‐horse Optimization (OSHO) algorithm has been proposed. The OSHO is compared with a few existing, well‐known meta‐heuristic algorithms to show its superiority. The analysis has been conducted under different operating conditions, including step and random disturbances as well as the IEEE‐39 bus, to verify the robustness as well as adaptability of the suggested controller. The comprehensive results of the studies provide strong evidence in support of the effectiveness and efficacy of the suggested control methods and suggest that it has the potential to be implemented in real‐world power systems for improved performance and stability.