Min-Yuan Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Min-Yuan Cheng has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jui-Sheng Chou
National Taiwan University of Science and Technology, Taipei, Taiwan
2 shared publications Andrés Lepage
Department of Civil Environmental, and Architectural Engineering The University of Kansas Lawrence USA
1 shared publicationBasyaruddin
1 shared publication- Basyaruddin
Dept. of Civil Engineering, Institut Teknologi Kalimatan, Balikpapan, Indonesia
1 shared publication - Chen-Ming Lee
National Taiwan University of Science and Technology, Taipei, Taiwan
1 shared publication Cheng-Cheng Chen
Professor, Dept. of Civil and Construction Engineering, National Taiwan Univ. of Science and Technology, Taipei City 10607, Taiwan
1 shared publication
Latest Publications
- 1 October 2024
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 150 (10)
Cyclic Behavior of Steel Tube-Confined Circular RC Columns under High Axial Load
- 1 October 2024
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 150 (10)
Cyclic Behavior of Steel Tube-Confined Circular RC Columns under High Axial Load
- 30 September 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 97
Dynamic Gradient Boosted Metaheuristic approach for efficient reinforced concrete structure optimization
- 30 September 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 97
Dynamic Gradient Boosted Metaheuristic approach for efficient reinforced concrete structure optimization
- 20 September 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (1) , 89-115
Shake table tests to compare the seismic response of concrete frames with conventional and high‐strength reinforcement
Reported test results suggest reinforcement grade can have an important effect on the seismic displacement demands of reinforced concrete (RC) structures. Two one‐story one‐bay RC frames (Specimens C1 and H1) were mounted in parallel on the NCREE‐Taiwan shake table and simultaneously subjected to 16 base motions, each representing a horizontal component of recorded earthquakes. The dynamic tests were followed by quasi‐static large‐amplitude cyclic testing. The specimens had the same nominal dimensions and base shear strengths with longitudinal reinforcement that was Grade 60 (60 ksi [420 MPa]) in C1 and Grade 100 (100 ksi [690 MPa]) in H1. Maximum drifts of H1 were 1.3 to 2.3 times larger than for C1. The lateral stiffness of H1 was consistently lower than C1, with stiffness ratios (H1 to C1) ranging from 0.78 after Run 1 to 0.45 after Run 16. Drift estimates using stiffness values based on gross‐section properties provided a reasonable upper bound for C1 but were unconservative for H1. Drift estimates based on the secant‐to‐yield stiffnesses, which were inversely proportional to reinforcement grade, provided an upper bound for both specimens. Preliminary recommendations are made for accounting for these effects in design.
- 20 September 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (1) , 89-115
Shake table tests to compare the seismic response of concrete frames with conventional and high‐strength reinforcement
Reported test results suggest reinforcement grade can have an important effect on the seismic displacement demands of reinforced concrete (RC) structures. Two one‐story one‐bay RC frames (Specimens C1 and H1) were mounted in parallel on the NCREE‐Taiwan shake table and simultaneously subjected to 16 base motions, each representing a horizontal component of recorded earthquakes. The dynamic tests were followed by quasi‐static large‐amplitude cyclic testing. The specimens had the same nominal dimensions and base shear strengths with longitudinal reinforcement that was Grade 60 (60 ksi [420 MPa]) in C1 and Grade 100 (100 ksi [690 MPa]) in H1. Maximum drifts of H1 were 1.3 to 2.3 times larger than for C1. The lateral stiffness of H1 was consistently lower than C1, with stiffness ratios (H1 to C1) ranging from 0.78 after Run 1 to 0.45 after Run 16. Drift estimates using stiffness values based on gross‐section properties provided a reasonable upper bound for C1 but were unconservative for H1. Drift estimates based on the secant‐to‐yield stiffnesses, which were inversely proportional to reinforcement grade, provided an upper bound for both specimens. Preliminary recommendations are made for accounting for these effects in design.
- 3 January 2022
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 29 (4) , e2918
Identifying deflections of reinforced concrete beams under seismic loads by bio‐inspired optimization of deep residual learning
- 3 January 2022
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 29 (4) , e2918
Identifying deflections of reinforced concrete beams under seismic loads by bio‐inspired optimization of deep residual learning
- Open Access
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 620 (1) , 012063
Issues of shear deformation measurement in experimental studies
Shear deformation determined using “X configuration method” as traditional instrumentation plan is controversial. Shear deformation of two specimens was re-investigated in this research. One of those (SP3) was representing a RC beam member using a single curvature test scenario and a coupling beam specimen (CB2) was representing a RC beam member using double curvature test scenario. The new instrumentation technology, optical system, provides a useful tool to evaluate different traditional instrumentation plans. Shear deformation is evaluated with different gauge lengths. The best-possible solutions of both specimens are determined using the optical system with the finest grid. Error is estimated by comparing results from “X Configuration” method with the best-possible solution. Analysis results indicate that the smaller gauge length yields the better results. A gauge length of 6.3 in. (160 mm) from X configuration method gives the smallest error, less than 10 %, in measuring shear deformation in a flexural governed member. It suggests that the gauge length to \measure shear deformation in a coupling beam specimen can be limited within 16.5 in. (420 mm). The largest gauge length from X configuration method in measuring shear deformation shows the largest error for both specimen SP3 and specimen CB2.
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 620 (1) , 012063
Open AccessIssues of shear deformation measurement in experimental studies
Shear deformation determined using “X configuration method” as traditional instrumentation plan is controversial. Shear deformation of two specimens was re-investigated in this research. One of those (SP3) was representing a RC beam member using a single curvature test scenario and a coupling beam specimen (CB2) was representing a RC beam member using double curvature test scenario. The new instrumentation technology, optical system, provides a useful tool to evaluate different traditional instrumentation plans. Shear deformation is evaluated with different gauge lengths. The best-possible solutions of both specimens are determined using the optical system with the finest grid. Error is estimated by comparing results from “X Configuration” method with the best-possible solution. Analysis results indicate that the smaller gauge length yields the better results. A gauge length of 6.3 in. (160 mm) from X configuration method gives the smallest error, less than 10 %, in measuring shear deformation in a flexural governed member. It suggests that the gauge length to \measure shear deformation in a coupling beam specimen can be limited within 16.5 in. (420 mm). The largest gauge length from X configuration method in measuring shear deformation shows the largest error for both specimen SP3 and specimen CB2.
- 11 July 2013
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 18 (1) , 24-40
Seismic Design Issue of Corner Slab-Column Connection
Design criteria of slab-column connections in the ACI Building Code [2011] were mostly developed from experimental results of interior connections. When dealing with corner slab-column connections, supplementary documents published by ACI Committee 352 and Committee 421 provide better explanations than the ACI Building Code [2011] and become useful references for practical engineers. However, different design values can be obtained using approaches recommended by different documents. In this article, a summary of this issue is presented. Among several design parameters discussed in this article, bi-axial moment, gravity shear ratio and column rectangularity have more significant effect to enlarge the discrepancy.
- 11 July 2013
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 18 (1) , 24-40
Seismic Design Issue of Corner Slab-Column Connection
Design criteria of slab-column connections in the ACI Building Code [2011] were mostly developed from experimental results of interior connections. When dealing with corner slab-column connections, supplementary documents published by ACI Committee 352 and Committee 421 provide better explanations than the ACI Building Code [2011] and become useful references for practical engineers. However, different design values can be obtained using approaches recommended by different documents. In this article, a summary of this issue is presented. Among several design parameters discussed in this article, bi-axial moment, gravity shear ratio and column rectangularity have more significant effect to enlarge the discrepancy.
- 30 October 2012
- Published by Springer Nature in Natural Hazards
- Vol. 65 (3) , 2031-2061
Emergency shelter capacity estimation by earthquake damage analysis
- 30 October 2012
- Published by Springer Nature in Natural Hazards
- Vol. 65 (3) , 2031-2061
Emergency shelter capacity estimation by earthquake damage analysis