ANAndrew Nyman

Andrew Nyman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew Nyman has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Standard concentrations of intravenous continuous drug infusions: evaluation of adherence, safety and effectiveness in paediatric critical care as quality improvement initiative

    by Sara Arenas-Lopez, Joanne Perkins, Shane Tibby, Andrew Gustaf Nyman, Virginia Aguado-Lorenzo

    To evaluate the introduction of locally configured standard concentration (StdC) intravenous drug infusions in critically ill children. This two-year quality improvement retrospective cohort study (2018-20) examined post-implementation of 47 StdC drugs configured across three weight bands: 20 kg in a 26-bed, multispecialty paediatric intensive care unit. The main outcome measures were (1) adherence to StdC use (non-adherence defined as using a bespoke drug concentration), (2) attempts at dosing above the pre-set infusion rates, known as hard limit events (HLEs), (3) incidents related to infusions and (4) percentage of total fluid allowance available for nutrition. In total, 33 224 infusions were administered, with morphine, clonidine and milrinone representing 61%. Most of them (83.6%) were initiated in children in the lower weight bands. Adherence to StdCs was 96% and was similar across weight bands. A total of 204 498 pump programming events were examined, with 418 (0.2%) being HLEs. Only 21 HLEs (0.01%) were considered potentially clinically significant (defined as programming >2.5 times the maximum dose). Following investigation, 20/21 were found likely to be related to training episodes, rather than true errors. Twenty clinical incidents linked to StdC infusions were reported but none caused harm. The mean fluid allowance available for nutrition after accounting for StdC volumes was 38.8% in the <5 kg weight band, and 71% and 67.4% in the other two bands, respectively. Configured StdCs are effective and safe across all weight bands and allow for partial provision of nutritional needs in fluid-restricted patients. The high adherence rate facilitated pharmacy supplying infusions as Ready-To-Administer (RTA).

  • Vascular rings in the current era: is this a new disease requiring a new approach?

    by Maya Asir, Kirsty Brennan, Jane Heraghty, Alice Hurn, Haran Jogeesvaran, Grace Moriarty, Andrew Nyman, Simona Turcu, Trisha V Vigneswaran

    Historically, vascular rings, formed by a right or double aortic arch, have been diagnosed in childhood following symptoms or signs of tracheo-oesophageal compression. Many of these features might be attributed to other non-surgical diagnoses, such as asthma, postviral symptoms or simply, sensory feeding behaviours. This has often led to families being falsely reassured, resulting in delayed referral to specialist services for assessment and definitive surgical treatment. Despite surgery, it is common for these postnatally diagnosed patients to have persistent symptoms. In the modern era, most vascular rings are diagnosed prenatally, having been identified on routine ultrasound screening in mid-pregnancy. This has resulted in an exponential increase in the diagnosis of the right aortic arch and double aortic arch, leading to a new form of these conditions for health practitioners to manage—a diagnosis prior to possible clinical presentation. Early symptoms of a vascular ring may be subtle, atypical or not evident despite having a significant degree of tracheal compression, and thus, there is a window for early intervention before symptoms affect a child’s health. Understanding which patients with vascular rings can be managed conservatively and which require surgery to improve outcomes and reduce longer-term morbidity and physical limitations is crucial. The recent literature on the diagnosis, assessment, management and outcomes of isolated vascular rings is reviewed, and our institutional pathway to manage these patients is discussed.

  • Open Access

    Evaluation of efficacy, outcomes and safety of infant haemodialysis and ultrafiltration in clinical use: I-KID a stepped wedge cluster RCT

    by Heather Lambert, Shaun Hiu, Malcolm Coulthard, John N S Matthews, Ruth Wood, Jean Crosier, Rachel Agbeko, Thomas Brick, Heather Duncan, David Grant, et al.

    Background: Critically unwell babies in intensive care units may develop acute renal failure. Options for renal replacement therapy are limited by their small size and available technology. Objectives: To determine the clinical efficacy, outcomes and safety profile of the NIDUS® (a novel infant haemodialysis device) for babies under 8 kg, compared with current renal replacement therapy. Design: A clinical investigation using a non-blinded cluster stepped wedge design with paediatric intensive care units randomised to sequences. Setting: Paediatric intensive care units in six UK hospitals. Participants: Children under 8 kg who required renal replacement therapy for fluid overload or biochemical disturbance. Interventions: Continuous renal replacement therapy was provided by the usual methods: peritoneal dialysis and continuous haemofiltration (during control periods) and by the NIDUS (during intervention periods), a novel device designed for babies with a smaller circuit and filter and volumetric control of ultrafiltration. Main outcome measures: Primary outcome was precision of ultrafiltration compared with prescription; secondary outcomes included biochemical clearances, accuracy of reported ultrafiltration and mortality. Data sources: Bedside study data collected by weighing bags of fluid entering and leaving the device were entered into the study database along with case descriptors. Some secondary outcome data was collected via the Paediatric Intensive Care Audit Network. Results: Ninety-seven participants were recruited by study closure, 62 to control and 35 to intervention. The primary outcome was obtained from 62 control but only 21 intervention patients, largely because of technical difficulties using NIDUS. The analysis comparing the available primary outcomes showed that ultrafiltration with NIDUS was closer to that prescribed than with control: standard deviations controls 18.75, intervention 2.95 (ml/hour), adjusted ratio 0.13, 95% confidence interval (0.03 to 0.71); p = 0.018. The mean clearances for creatinine, urea and phosphate were lower on peritoneal dialysis than NIDUS, which were in turn lower than continuous veno-venous haemofiltration. The variability in the clearances was in the same order. Of the 62 control patients, 10 died (2/62 on peritoneal dialysis; 7/13 on continuous haemofiltration) before discharge from paediatric intensive care unit (16%), compared with 12 out of 35 (34%) in the NIDUS group: p = 0.04, 95% confidence interval for difference (0 to 36%). Harms: No important adverse events occurred and the NIDUS has an acceptable safety profile compared with other renal replacement therapies in this critically ill population with multi-organ failure. Mortality was lowest for Peritoneal Dialysis, highest for continuous haemofiltration, with the NIDUS in-between. Only one serious adverse device event which was reported to the Medicines and Healthcare products Regulatory Agency. Conclusions: NIDUS works effectively, delivering appropriate blood clearances and accurate, controllable fluid removal (ultrafiltration), indicating that it has an important place alongside other dialysis modalities for infant renal replacement therapy. Future work: Findings from this study indicate some modifications are required to NIDUS to improve usability. Further studies on use of the NIDUS device in other populations of babies for example those with chronic renal failure, and long-term outcomes are required. Trial registration: This trial is registered as ISRCTN 13787486. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Efficacy and Mechanism Evaluation Programme (NIHR award ref: 14/23/26) and is published in full in Efficacy and Mechanism Evaluation; Vol. 11, No. 1. See the NIHR Funding and Awards website for further award information.


  • Single‐center review on safety of biodegradable airway stenting in pediatric population

    by Federico Minen, Andrew Durward, Paul James, Athanasios Diamantopoulos, Haran Jogeesvaran, Gareth J. Morgan, Andrew Nyman

    Background: Tracheobronchomalacia (TBM) and airway stenosis are recognized etiologies of airway obstruction among children. Their management is often challenging, requiring multiple interventions and prolonged respiratory support with associated long‐term morbidity. Metallic or silicone stents have been used with mixed success and high complication rates. More recently biodegradable Ella stents (BES) provided an attractive interventional option.Objectives: We report our experience in the treatment of TBM and vascular airway compression using BES. We deliberately downsized them to minimize intraluminal granulation tissue formation.Materials and Methods: Retrospective study over an 8‐year period between November 2012 and December 2020 of pediatric patients with severe airway obstruction requiring airway stenting for extubation failure, malacic death spells, recurrent chest infections, or lung collapse.Results: Thirty‐three patients (5 tracheal and 28 bronchial diseases) required 55 BES during the study period. The smallest patient weighed 1.8 kg. Median age of patient at first stent implantation was 13.1 months (IQR 4.9–58.3). The majority of the bronchial stents were in the left main bronchus (93%), of which 57% for vascular compression. Repeat stents were used in 19 patients (57.7%), with a range of two to four times. We did not experience erosion, infection, or obstructive granuloma needing removal by forceps or lasering. Three stent grid occluded with secretions needing bronchoscopic lavage. Stent migration occurred in three patients.Conclusions: BES holds promise as a treatment option with low rate of adverse effects for a specific subset of pediatric patients with airway malacia or vascular compression. Further studies are warranted.


  • Biodegradable Stents for the Relief of Vascular Bronchial Compression in Children With Left Atrial Enlargement

    by Benedict T. Mbbs Griffiths, Paul Mbbch James, Gareth Mbbch Morgan, Athanasios Ptychio Iatrikes Diamantopoulos, Andrew MBChB Durward, Andrew Mbbch Nyman

    Background: We report our experience of the biodegradable polydioxanone stent in cases of bronchial compression by a dilated left atrium in children with heart disease. Methods: Eight custom-made biodegradable stents were inserted into the left main bronchus in 5 patients diagnosed with critical airway compression. Four of the 5 patients were ventilator-dependent with significant cardiac morbidity. Results: Stents were inserted without complication under fluoroscopic guidance. All experienced improvement in symptoms over time. In 3 patients, repeat bronchial stenting was performed where stent degradation was associated with recurrence of vascular airway compression and symptoms. No stents migrated nor was there evidence of bronchial or vascular erosion. There was 1 death, unrelated to the stent, and all remaining survivors were well at a 2-year follow-up. Conclusion: The use of the polydioxanone biodegradable stent appeared safe in this cohort of critically ill patients with vascular bronchial compression. There use may aid weaning from mechanical ventilation and support eventual cardiac recovery.


  • Case-based discussion from the neonatal intensive care unit: a case of an intentional oesophageal intubation

    by Katharine Jamieson, Stephanie Boyd, Susern Tan, Davina Wong, Paul James, Andrew Durward, Andrew Nyman

    Tracheal agenesis (TA) is a rare congenital defect consisting of complete or partial absence of the trachea below the larynx. Antenatal diagnosis is challenging, and most cases are detected in the postnatal period. Airway management of such cases, particularly in the absence of antenatal diagnosis, can be challenging. Various methods of management have been described but with limited success, and overall prognosis remains very poor. We present an unexpected case of TA, highlighting management issues and diagnostic methods.

  • Safety and efficacy of rescue flexible bronchoscopic intubation using the Bentson floppy‐tip guidewire via a supraglottic airway in critically ill children

    by D. Cross, A. Nyman, P. James, A. Durward

    Summary: Difficulty in tracheal intubation in paediatric intensive care patients is associated with increased morbidity and mortality. Delays to intubation and interruption to oxygenation and ventilation are poorly tolerated. We developed a safe and atraumatic tracheal intubation technique. A floppy‐tipped guidewire and airway exchange catheter were placed to a pre‐determined length under bronchoscopic guidance while oxygenation and ventilation was maintained via a supraglottic airway device ( SAD ). We performed a retrospective review of this technique on patients who were either known to have or who had an unexpected difficultly in intubation. We describe the safety and experience of this in a broad range of critically ill children. Thirteen patients, median (IQR [range]) (9.0 (5.0–10.0 [4.0–12.0]) kg and 15.4 (12.1–23.2 [3.3–49.7]) months) underwent emergency tracheal intubation using this technique, after unsuccessful attempts at intubation using standard laryngoscopy blades. All intubations were successful at the first attempt using this technique and no airway trauma or significant clinical deteriorations were recorded.