Zhuohan Gu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zhuohan Gu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ashwin Seetharaman
Department of Biomedical Engineering, National University of Singapore, Singapore 119077, Singapore
1 shared publication - Chi Wei Ong
School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore
1 shared publication - Ganesh Ananthanarayanan
Microsoft, Redmond, USA
1 shared publication - Hwa Liang Leo
National University of Singapore
1 shared publication - Junchen Jiang
The University of Chicago
1 shared publication - Kollengode Ramanathan
Yong Loo Lin School of Medicine, National University of Singapore, National University Health System, Singapore
1 shared publication
Latest Publications
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 606-622
METIS: Fast Quality-Aware RAG Systems with Configuration Adaptation
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 606-622
Open AccessMETIS: Fast Quality-Aware RAG Systems with Configuration Adaptation
- Open Access
- 1 October 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (6) , 465
The Impact of Left Ventricular Assist Device Outflow Graft Positioning on Aortic Hemodynamics: Improving Flow Dynamics to Mitigate Aortic Insufficiency
Heart failure is a global health concern with significant implications for healthcare systems. Left ventricular assist devices (LVADs) provide mechanical support for patients with severe heart failure. However, the placement of the LVAD outflow graft within the aorta has substantial implications for hemodynamics and can lead to aortic insufficiency during long-term support. This study employs computational fluid dynamics (CFD) simulations to investigate the impact of different LVAD outflow graft locations on aortic hemodynamics. The introduction of valve morphology within the aorta geometry allows for a more detailed analysis of hemodynamics at the aortic root. The results demonstrate that the formation of vortex rings and subsequent vortices during the high-velocity jet flow from the graft interacted with the aortic wall. Time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI) indicate that modification of the outflow graft location changes mechanical states within the aortic wall and aortic valve. Among the studied geometric factors, both the height and inclination angle of the LVAD outflow graft are important in controlling retrograde flow to the aortic root, while the azimuthal angle primarily determines the rotational direction of blood flow in the aortic arch. Thus, precise positioning of the LVAD outflow graft emerges as a critical factor in optimizing patient outcomes by improving the hemodynamic environment.
- 1 October 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (6) , 465
Open AccessThe Impact of Left Ventricular Assist Device Outflow Graft Positioning on Aortic Hemodynamics: Improving Flow Dynamics to Mitigate Aortic Insufficiency
Heart failure is a global health concern with significant implications for healthcare systems. Left ventricular assist devices (LVADs) provide mechanical support for patients with severe heart failure. However, the placement of the LVAD outflow graft within the aorta has substantial implications for hemodynamics and can lead to aortic insufficiency during long-term support. This study employs computational fluid dynamics (CFD) simulations to investigate the impact of different LVAD outflow graft locations on aortic hemodynamics. The introduction of valve morphology within the aorta geometry allows for a more detailed analysis of hemodynamics at the aortic root. The results demonstrate that the formation of vortex rings and subsequent vortices during the high-velocity jet flow from the graft interacted with the aortic wall. Time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI) indicate that modification of the outflow graft location changes mechanical states within the aortic wall and aortic valve. Among the studied geometric factors, both the height and inclination angle of the LVAD outflow graft are important in controlling retrograde flow to the aortic root, while the azimuthal angle primarily determines the rotational direction of blood flow in the aortic arch. Thus, precise positioning of the LVAD outflow graft emerges as a critical factor in optimizing patient outcomes by improving the hemodynamic environment.