PJPaul Jäger

Paul Jäger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul Jäger has a total of 163 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Including AI in diffusion-weighted breast MRI has potential to increase reader confidence and reduce workload

    by Dimitrios Bounias, Lina Simons, Michael Baumgartner, Chris Ehring, Peter Neher, Lorenz A Kapsner, Balint Kovacs, Ralf Floca, Paul F Jaeger, Jessica Eberle, et al.

    Objectives: Breast diffusion-weighted imaging (DWI) has shown potential as a standalone imaging technique for certain indications, eg, supplemental screening of women with dense breasts. This study evaluates an artificial intelligence (AI)-powered computer-aided diagnosis (CAD) system for clinical interpretation and workload reduction in breast DWI. Materials and Methods: This retrospective IRB-approved study included: n = 824 examinations for model development (2017-2020) and n = 235 for evaluation (01/2021-06/2021). Readings were performed by three readers using either the AI-CAD or manual readings. BI-RADS-like (Breast Imaging Reporting and Data System) classification was based on DWI. Histopathology served as ground truth. The model was nnDetection-based, trained using 5-fold cross-validation and ensembling. Statistical significance was determined using McNemar’s test. Inter-rater agreement was calculated using Cohen’s kappa. Model performance was calculated using the area under the receiver operating curve (AUC). Results: The AI-augmented approach significantly reduced BI-RADS-like 3 calls in breast DWI by 29% (P =.019) and increased interrater agreement (0.57 ± 0.10 vs 0.49 ± 0.11), while preserving diagnostic accuracy. Two of the three readers detected more malignant lesions (63/69 vs 59/69 and 64/69 vs 62/69) with the AI-CAD. The AI model achieved an AUC of 0.78 (95% CI: [0.72, 0.85]; P <.001), which increased for women at screening age to 0.82 (95% CI: [0.73, 0.90]; P <.001), indicating a potential for workload reduction of 20.9% at 96% sensitivity. Discussion and Conclusion: Breast DWI might benefit from AI support. In our study, AI showed potential for reduction of BI-RADS-like 3 calls and increase of inter-rater agreement. However, given the limited study size, further research is needed.

  • Open Access

    Navigating prevalence shifts in image analysis algorithm deployment

    by Patrick Godau, Piotr Kalinowski, Evangelia Christodoulou, Annika Reinke, Minu Tizabi, Luciana Ferrer, Paul Jäger, Lena Maier-Hein


  • Open Access

    Application-driven validation of posteriors in inverse problems

    by Tim J. Adler, Jan-Hinrich Nölke, Annika Reinke, Minu Dietlinde Tizabi, Sebastian Gruber, Dasha Trofimova, Lynton Ardizzone, Paul F. Jaeger, Florian Buettner, Ullrich Köthe, et al.


  • Open Access

    Comparative benchmarking of failure detection methods in medical image segmentation: Unveiling the role of confidence aggregation

    by Maximilian Zenk, David Zimmerer, Fabian Isensee, Jeremias Traub, Tobias Norajitra, Paul F. Jäger, Klaus Maier-Hein


  • Open Access

    Deep Interactive Segmentation of Medical Images: A Systematic Review and Taxonomy

    by Zdravko Marinov, Paul F. Jäger, Jan Egger, Jens Kleesiek, Rainer Stiefelhagen

    Interactive segmentation is a crucial research area in medical image analysis aiming to boost the efficiency of costly annotations by incorporating human feedback. This feedback takes the form of clicks, scribbles, or masks and allows for iterative refinement of the model output so as to efficiently guide the system towards the desired behavior. In recent years, deep learning-based approaches have propelled results to a new level causing a rapid growth in the field with 121 methods proposed in the medical imaging domain alone. In this review, we provide a structured overview of this emerging field featuring a comprehensive taxonomy, a systematic review of existing methods, and an in-depth analysis of current practices. Based on these contributions, we discuss the challenges and opportunities in the field. For instance, we find that there is a severe lack of comparison across methods which needs to be tackled by standardized baselines and benchmarks.


  • Open Access

    Abstract: Anatomy-informed Data Augmentation for Enhanced Prostate Cancer Detection

    by Balint Kovacs, Nils Netzer, Michael Baumgartner, Carolin Eith, Dimitrios Bounias, Clara Meinzer, Paul F. Jäger, Kevin S. Zhang, Ralf Floca, Adrian Schrader, et al.


  • Top Cited Papers
    Open Access

    Understanding metric-related pitfalls in image analysis validation

    by Annika Reinke, Minu D. Tizabi, Michael Baumgartner, Matthias Eisenmann, Doreen Heckmann-Nötzel, A. Emre Kavur, Tim Rädsch, Carole H. Sudre, Laura Acion, Michela Antonelli, et al.

    Validation metrics are key for tracking scientific progress and bridging the current chasm between artificial intelligence research and its translation into practice. However, increasing evidence shows that, particularly in image analysis, metrics are often chosen inadequately. Although taking into account the individual strengths, weaknesses and limitations of validation metrics is a critical prerequisite to making educated choices, the relevant knowledge is currently scattered and poorly accessible to individual researchers. Based on a multistage Delphi process conducted by a multidisciplinary expert consortium as well as extensive community feedback, the present work provides a reliable and comprehensive common point of access to information on pitfalls related to validation metrics in image analysis. Although focused on biomedical image analysis, the addressed pitfalls generalize across application domains and are categorized according to a newly created, domain-agnostic taxonomy. The work serves to enhance global comprehension of a key topic in image analysis validation.


  • Top Cited Papers
    Open Access

    Metrics reloaded: recommendations for image analysis validation

    by Lena Maier-Hein, Annika Reinke, Patrick Godau, Minu D. Tizabi, Florian Buettner, Evangelia Christodoulou, Ben Glocker, Fabian Isensee, Jens Kleesiek, Michal Kozubek, et al.

    Increasing evidence shows that flaws in machine learning (ML) algorithm validation are an underestimated global problem. In biomedical image analysis, chosen performance metrics often do not reflect the domain interest, and thus fail to adequately measure scientific progress and hinder translation of ML techniques into practice. To overcome this, we created Metrics Reloaded, a comprehensive framework guiding researchers in the problem-aware selection of metrics. Developed by a large international consortium in a multistage Delphi process, it is based on the novel concept of a problem fingerprint—a structured representation of the given problem that captures all aspects that are relevant for metric selection, from the domain interest to the properties of the target structure(s), dataset and algorithm output. On the basis of the problem fingerprint, users are guided through the process of choosing and applying appropriate validation metrics while being made aware of potential pitfalls. Metrics Reloaded targets image analysis problems that can be interpreted as classification tasks at image, object or pixel level, namely image-level classification, object detection, semantic segmentation and instance segmentation tasks. To improve the user experience, we implemented the framework in the Metrics Reloaded online tool. Following the convergence of ML methodology across application domains, Metrics Reloaded fosters the convergence of validation methodology. Its applicability is demonstrated for various biomedical use cases.


  • Open Access

    Addressing image misalignments in multi-parametric prostate MRI for enhanced computer-aided diagnosis of prostate cancer

    by Balint Kovacs, Nils Netzer, Michael Baumgartner, Adrian Schrader, Fabian Isensee, Cedric Weißer, Ivo Wolf, Magdalena Görtz, Paul F. Jaeger, Victoria Schütz, et al.

    Prostate cancer (PCa) diagnosis on multi-parametric magnetic resonance images (MRI) requires radiologists with a high level of expertise. Misalignments between the MRI sequences can be caused by patient movement, elastic soft-tissue deformations, and imaging artifacts. They further increase the complexity of the task prompting radiologists to interpret the images. Recently, computer-aided diagnosis (CAD) tools have demonstrated potential for PCa diagnosis typically relying on complex co-registration of the input modalities. However, there is no consensus among research groups on whether CAD systems profit from using registration. Furthermore, alternative strategies to handle multi-modal misalignments have not been explored so far. Our study introduces and compares different strategies to cope with image misalignments and evaluates them regarding to their direct effect on diagnostic accuracy of PCa. In addition to established registration algorithms, we propose ‘misalignment augmentation’ as a concept to increase CAD robustness. As the results demonstrate, misalignment augmentations can not only compensate for a complete lack of registration, but if used in conjunction with registration, also improve the overall performance on an independent test set.


  • Anatomy-Informed Data Augmentation for Enhanced Prostate Cancer Detection

    by Balint Kovacs, Nils Netzer, Michael Baumgartner, Carolin Eith, Dimitrios Bounias, Clara Meinzer, Paul F. Jäger, Kevin S. Zhang, Ralf Floca, Adrian Schrader, et al.