DHDerek Hogue

Derek Hogue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Derek Hogue has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Treavor H. Boyer

    School of Sustainable Engineering and the Built Environment (SSEBE), Arizona State University, PO Box 873005, Tempe, Arizona 85287-3005, United States

    2 shared publications
  • James Brown

    The School of Sustainable Engineering and the Built Environment, Arizona State University, 660S College Ave, Tempe, AZ 85281, USA

    1 shared publication
  • Jumana Alja'FAri

    The Biodesign Institute Center for Environmental Health Engineering, Arizona State University, 1001 S McAlister Ave, Tempe, AZ 85281, USA

    1 shared publication
  • Kathryn Call

    The School of Sustainable Engineering and the Built Environment, Arizona State University, 660S College Ave, Tempe, AZ 85281, USA

    1 shared publication
  • Kerry Ann Hamilton

    The Biodesign Institute Center for Environmental Health Engineering Arizona State University Tempe Arizona USA

    1 shared publication
  • Lee Emerson Voth-Gaeddert

    Biodesign Center for Health through Microbiomes, Arizona State University, Tempe, AZ 85281, USA

    1 shared publication

Latest Publications

  • Pilot‐Scale Analysis of Stagnation and Flushing in Premise Plumbing

    by Derek Hogue, McKenzie Steele, Treavor H. Boyer

    Research has demonstrated that water quality degrades in commercial and institutional (C&I) building premise plumbing leading to increased risk to consumers. This study aimed to bridge the gap between real premise plumbing systems and theory by using a pilot scale pipe rig representative of C&I premise plumbing. The research examined changes in key water quality parameters, including chlorine, copper, trihalomethanes (THMs), and cellular ATP (cATP) across different flushing and stagnation conditions. Results indicated significant degradation during periods of stagnation found in real premise plumbing, with reductions in chlorine levels and increases in copper and THM concentrations. Conversely, flushing effectively renewed water quality, though the extent varied with system size and flow dynamics. Correlations were found between key water quality variables. The findings emphasize the need for strategic water management practices to mitigate risks associated with poor water quality in building plumbing systems.


  • Water quality trade-offs for risk management interventions in a green building

    by Sayalee Joshi, Sayalee Joshi, Rain Richard, Rain Richard, Derek Hogue, Derek Hogue, James Brown, James Brown, Molly Cahill, Molly Cahill, et al.

    Premise plumbing water quality degradation has led to negative health impacts from pathogen outbreaks (e.g., Legionella pneumophila and non-tuberculous mycobacteria), as well as chronic effects from exposure to heavy metals or disinfection by-products (DBP). Common water quality management interventions include flushing, heat shock (thermal disinfection), supplemental disinfection (shock or super chlorination), and water heater temperature setpoint change. In this study, a Legionella pneumophila – colonized Leadership in Energy and Environmental Design (LEED) certified building was monitored to study health-relevant water quality changes before and after three controlled management interventions: (1) flushing at several points throughout the building; (2) changing the water heater set point; and (3) a combination of interventions (1) and (2) by flushing during a period of elevated water heater set point (incompletely performed due to operational issues). Microbial (culturable L. pneumophila, the L. pneumophila mip gene, and cATP) and physico-chemical (pH, temperature, conductivity, disinfectant residual, disinfection by-products (DBPs; total trihalomethanes, TTHM), and heavy metals) water quality parameters were monitored alongside building occupancy as approximated using Wi-Fi logins. Flushing alone resulted in a significant decrease in cATP and L. pneumophila concentrations (p = 0.018 and 0.019, respectively) and a significant increase in chlorine concentrations (p = 0.002) as well as iron and DBP levels (p = 0.002). Copper concentrations increased during the water heater temperature setpoint increase alone to 140 °F during December 2022 (p = 0.01). During the flushing and elevated temperature in parts of the building in February 2023, there was a significant increase in chlorine concentrations (p = 0.002) and iron (p = 0.002) but no significant decrease in L. pneumophila concentrations in the drinking water samples (p = 0.27). This study demonstrated the potential impacts of short-term or incompletely implemented interventions which in this case were not sufficient to holistically improve water quality. As implementing interventions is logistically- and time-intensive, more effective approaches are needed for informing preventative and corrective actions that are beneficial for multiple water quality and sustainability goals.


  • Predictive capability of THM models for drinking water treatment and distribution

    by Derek Hogue, Pitu B. Mirchandani, Treavor H. Boyer

    This work evaluates generalizability of THM models and provides a framework to promote cohesive and collaborative model development efforts moving forward.