Larissa Krambeck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Larissa Krambeck has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Marcia Barbosa Henriques Mantelli
9 shared publications- Kelvin Guessi Domiciano
Federal University of Santa Catarina
8 shared publications - Thiago Antonini Alves
UTFPR
7 shared publications Davi Fusão
Universidade Tecnológica Federal do Paraná
6 shared publicationsGuilherme Antonio Bartmeyer
Universidade Tecnológica Federal do Paraná
6 shared publicationsKelvin Guessi Domiciano
Federal University of Santa Catarina,Heat Pipe Laboratory,Florianopolis,Brazil
6 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-10
Thermal-Hydraulic Analysis of Miniaturized Loop Heat Pipe
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-10
Thermal-Hydraulic Analysis of Miniaturized Loop Heat Pipe
- Open Access
- 14 June 2026
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 76
Thin loop heat pipe with twisted wires as wick structure for microelectronics
- 14 June 2026
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 76
Open AccessThin loop heat pipe with twisted wires as wick structure for microelectronics
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3258 (1)
Enhanced flat heat pipe with twisted wires as the capillary structure
The present research aims to refine and optimize a twisted wire wick structure for use in a flat heat pipe. A miniature flat heat pipe measuring 100 × 55 × 2.6 mm 3 was fabricated using diffusion bonding technology and tested under different working fluid volumes and orientations. The device consists of a sandwich structure formed by copper plates, with an internal capillary wick composed of 12 twisted-wire rolls made of thin copper wires obtained from standard commercial electrical cables. Thermal testing showed that the heat pipe performed reliably in all orientations, achieving a minimum thermal resistance of 0.159 °C/W in the horizontal position. Furthermore, its thermal performance was compared with that of the original reference designs. These results underscore the strong potential of twisted wire wicks as efficient, low-cost alternatives for capillary structures in two-phase heat transfer systems. The combination of good thermal performance and a simple, low-cost fabrication process makes this design particularly well-suited for electronics cooling applications.
- 1 June 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3258 (1)
Open AccessEnhanced flat heat pipe with twisted wires as the capillary structure
The present research aims to refine and optimize a twisted wire wick structure for use in a flat heat pipe. A miniature flat heat pipe measuring 100 × 55 × 2.6 mm 3 was fabricated using diffusion bonding technology and tested under different working fluid volumes and orientations. The device consists of a sandwich structure formed by copper plates, with an internal capillary wick composed of 12 twisted-wire rolls made of thin copper wires obtained from standard commercial electrical cables. Thermal testing showed that the heat pipe performed reliably in all orientations, achieving a minimum thermal resistance of 0.159 °C/W in the horizontal position. Furthermore, its thermal performance was compared with that of the original reference designs. These results underscore the strong potential of twisted wire wicks as efficient, low-cost alternatives for capillary structures in two-phase heat transfer systems. The combination of good thermal performance and a simple, low-cost fabrication process makes this design particularly well-suited for electronics cooling applications.
- Open Access
Thermal Characterization of a Stainless Steel Flat Pulsating Heat Pipe and Benchmarking Against Copper
Copper is widely used in two-phase devices for electronic cooling due to its ease of manufacture and high thermal conductivity. However, such high-heat conduction can limit the performance of pulsating heat pipes (PHPs) through transverse heat leakage. The use of lower-conductivity materials such as stainless steel enhances phase-change heat transfer by promoting stronger flow oscillations and reducing parasitic heat leakage, but it may be overall detrimental due to its poor thermal linkage between evaporator and condenser sections. Therefore, in this study, two main objectives are addressed: (i) experimentally characterizing the thermal behavior of a mini flat-plate PHP made of stainless steel (AISI 316L), and (ii) benchmarking its performance against a copper counterpart. Both devices were manufactured by diffusion bonding and tested under different orientations to evaluate operational robustness. The stainless steel PHP initiated oscillations at lower heat loads and showed larger temperature oscillations compared to the copper PHP, demonstrating effective phase-change heat transfer despite its lower thermal conductivity. A filling ratio of 71% of water provided the most stable operation, while orientation affected startup conditions and oscillation amplitude. Overall, stainless steel achieved comparable thermal performance to copper at low-to-moderate heat loads from 2.6 to 13.0 W/cm2, with additional benefits including reduced mass (~11% lighter), higher mechanical strength, and corrosion resistance. These results indicate that stainless steel is a viable alternative to copper at least for miniature flat-plate PHPs, offering a balance between thermal efficiency, mechanical robustness, and operational reliability.
Open AccessThermal Characterization of a Stainless Steel Flat Pulsating Heat Pipe and Benchmarking Against Copper
Copper is widely used in two-phase devices for electronic cooling due to its ease of manufacture and high thermal conductivity. However, such high-heat conduction can limit the performance of pulsating heat pipes (PHPs) through transverse heat leakage. The use of lower-conductivity materials such as stainless steel enhances phase-change heat transfer by promoting stronger flow oscillations and reducing parasitic heat leakage, but it may be overall detrimental due to its poor thermal linkage between evaporator and condenser sections. Therefore, in this study, two main objectives are addressed: (i) experimentally characterizing the thermal behavior of a mini flat-plate PHP made of stainless steel (AISI 316L), and (ii) benchmarking its performance against a copper counterpart. Both devices were manufactured by diffusion bonding and tested under different orientations to evaluate operational robustness. The stainless steel PHP initiated oscillations at lower heat loads and showed larger temperature oscillations compared to the copper PHP, demonstrating effective phase-change heat transfer despite its lower thermal conductivity. A filling ratio of 71% of water provided the most stable operation, while orientation affected startup conditions and oscillation amplitude. Overall, stainless steel achieved comparable thermal performance to copper at low-to-moderate heat loads from 2.6 to 13.0 W/cm2, with additional benefits including reduced mass (~11% lighter), higher mechanical strength, and corrosion resistance. These results indicate that stainless steel is a viable alternative to copper at least for miniature flat-plate PHPs, offering a balance between thermal efficiency, mechanical robustness, and operational reliability.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stainless-Steel Flat Plate Pulsating Heat Pipe: An Alternative for Electronic Cooling
The present study characterizes the thermal performance of a mini flat plate pulsating heat pipe (PHP) fabricated entirely from stainless steel using diffusion bonding, with the goal of assessing its viability as an alternative solution for electronics cooling. To ensure a comprehensive evaluation, the thermal performance of a copper mini flat PHP was also investigated under identical conditions. Experimental results revealed that the stainless-steel PHP exhibited enhanced phasechange behaviour due to reduced lateral conduction between channels, which promoted stronger temperature oscillations and improved heat transfer efficiency, particularly at low heat loads. While the copper PHP achieved higher maximum heat loads, the stainless-steel version attained comparable thermal resistance in the 80 to 100 W range, despite reduced container conduction, and offered a significant mass reduction of approximately 17 g. Also, stainless steel provides superior mechanical strength, corrosion resistance, and environmental advantages, making it a cost-effective and robust alternative to copper. These findings highlight the critical role of material selection in PHP design and demonstrate the strong potential of stainless steel for use in compact, lightweight, and highperformance thermal management systems for electronic devices.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stainless-Steel Flat Plate Pulsating Heat Pipe: An Alternative for Electronic Cooling
The present study characterizes the thermal performance of a mini flat plate pulsating heat pipe (PHP) fabricated entirely from stainless steel using diffusion bonding, with the goal of assessing its viability as an alternative solution for electronics cooling. To ensure a comprehensive evaluation, the thermal performance of a copper mini flat PHP was also investigated under identical conditions. Experimental results revealed that the stainless-steel PHP exhibited enhanced phasechange behaviour due to reduced lateral conduction between channels, which promoted stronger temperature oscillations and improved heat transfer efficiency, particularly at low heat loads. While the copper PHP achieved higher maximum heat loads, the stainless-steel version attained comparable thermal resistance in the 80 to 100 W range, despite reduced container conduction, and offered a significant mass reduction of approximately 17 g. Also, stainless steel provides superior mechanical strength, corrosion resistance, and environmental advantages, making it a cost-effective and robust alternative to copper. These findings highlight the critical role of material selection in PHP design and demonstrate the strong potential of stainless steel for use in compact, lightweight, and highperformance thermal management systems for electronic devices.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Thermal Performance of a Heat Pipe with Triangular Grooves for Battery Cooling Applications in Electric Vehicles
The increasing global concern with climate change has positioned electric vehicles (EVs) as a key technology for reducing greenhouse gas emissions and improving air quality. However, the thermal management of lithium-ion battery cells remains critical to preventing degradation, extending lifespan, and ensuring operational reliability. This study presents the design, fabrication, and experimental evaluation of an innovative heat pipe developed as a passive thermal management solution for cylindrical lithium-ion battery cells used in EV applications. To achieve this, a copper heat pipe was fabricated by welding three convex sheets, specifically shaped to conform to the curvature of three adjacent cylindrical cells, without altering the original module configuration. The contact between the curved surfaces forms triangular axial grooves that function as effective capillary structures. Ethanol was used as the working fluid, and several filling ratios were tested in a horizontal orientation. The best performance was achieved with a 15 % filling ratio, resulting in a minimum thermal resistance of $0.41 \pm 0.034^{\circ} \mathrm{C} / \mathrm{W}$ and a temperature reduction of approximately 8.5° C during a 30 A discharge cycle. These findings confirm the effectiveness of two-phase passive cooling and demonstrate that the proposed system is a compact, scalable, and energy-efficient solution for battery thermal management in electric vehicles.- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Thermal Performance of a Heat Pipe with Triangular Grooves for Battery Cooling Applications in Electric Vehicles
The increasing global concern with climate change has positioned electric vehicles (EVs) as a key technology for reducing greenhouse gas emissions and improving air quality. However, the thermal management of lithium-ion battery cells remains critical to preventing degradation, extending lifespan, and ensuring operational reliability. This study presents the design, fabrication, and experimental evaluation of an innovative heat pipe developed as a passive thermal management solution for cylindrical lithium-ion battery cells used in EV applications. To achieve this, a copper heat pipe was fabricated by welding three convex sheets, specifically shaped to conform to the curvature of three adjacent cylindrical cells, without altering the original module configuration. The contact between the curved surfaces forms triangular axial grooves that function as effective capillary structures. Ethanol was used as the working fluid, and several filling ratios were tested in a horizontal orientation. The best performance was achieved with a 15 % filling ratio, resulting in a minimum thermal resistance of $0.41 \pm 0.034^{\circ} \mathrm{C} / \mathrm{W}$ and a temperature reduction of approximately 8.5° C during a 30 A discharge cycle. These findings confirm the effectiveness of two-phase passive cooling and demonstrate that the proposed system is a compact, scalable, and energy-efficient solution for battery thermal management in electric vehicles.- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Effect of the Condenser on the Thermal Performance of a Mini Loop Heat Pipe
In the present study, the effect of the cooling heat transfer coefficient on the thermal performance of a loop heat pipe (LHP) was investigated. The diffusion-bonded LHP was specifically designed for electronics cooling, with overall dimensions of $76 \times 60 \times 1.6 \text{mm}$. As the heat transfer coefficient increased from approximately 62 to 641 W/m2 K, the LHP consistently exhibited the same startup heat load across all cases. However, while the higher heat transfer coefficients enabled the device to dissipate greater heat loads, the overall thermal performance was compromised. This study underscores the critical importance of the condenser in the design and optimization of two-phase cooling systems.- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Effect of the Condenser on the Thermal Performance of a Mini Loop Heat Pipe
In the present study, the effect of the cooling heat transfer coefficient on the thermal performance of a loop heat pipe (LHP) was investigated. The diffusion-bonded LHP was specifically designed for electronics cooling, with overall dimensions of $76 \times 60 \times 1.6 \text{mm}$. As the heat transfer coefficient increased from approximately 62 to 641 W/m2 K, the LHP consistently exhibited the same startup heat load across all cases. However, while the higher heat transfer coefficients enabled the device to dissipate greater heat loads, the overall thermal performance was compromised. This study underscores the critical importance of the condenser in the design and optimization of two-phase cooling systems.- 5 June 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 277
Twisted wire wick structure in a novel flat heat pipe
- 5 June 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 277
Twisted wire wick structure in a novel flat heat pipe
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 28 (suppl 1) , e20250065
Evaluation of Copper Diffusion Bonding Parameters Applied to the Manufacture of Flat Heat Pipes
Flat heat pipes are highly effective for electronic thermal management, combining compact design with efficient heat transfer. Diffusion bonding is a promising manufacturing method, enabling leak-tight joints without notable plastic deformation. This study examined the effects of bonding temperature and pressure on the quality of miniature copper heat pipe joints. Optical microscopy, microhardness tests, and shear strength evaluations were used for assessment. Optimal results occurred at 875°C and 7MPa. Among four temperatures and three pressures tested, 900°C and 9MPa also yielded strong joints. Bonding time was fixed at 3600s. Good joints showed shear strengths of 5.92–6.17MPa and microhardness of 45–49HV. Interfaces had small, rounded, well-distributed defects that did not impair integrity. Temperature had a greater impact than pressure on joint quality. A flat miniature loop heat pipe made under optimal conditions (875°C, 7MPa, 3600s) displayed high-quality, deformation-free bonding and transferred up to 8W before reaching its operational limit—suitable for electronics.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 28 (suppl 1) , e20250065
Open AccessEvaluation of Copper Diffusion Bonding Parameters Applied to the Manufacture of Flat Heat Pipes
Flat heat pipes are highly effective for electronic thermal management, combining compact design with efficient heat transfer. Diffusion bonding is a promising manufacturing method, enabling leak-tight joints without notable plastic deformation. This study examined the effects of bonding temperature and pressure on the quality of miniature copper heat pipe joints. Optical microscopy, microhardness tests, and shear strength evaluations were used for assessment. Optimal results occurred at 875°C and 7MPa. Among four temperatures and three pressures tested, 900°C and 9MPa also yielded strong joints. Bonding time was fixed at 3600s. Good joints showed shear strengths of 5.92–6.17MPa and microhardness of 45–49HV. Interfaces had small, rounded, well-distributed defects that did not impair integrity. Temperature had a greater impact than pressure on joint quality. A flat miniature loop heat pipe made under optimal conditions (875°C, 7MPa, 3600s) displayed high-quality, deformation-free bonding and transferred up to 8W before reaching its operational limit—suitable for electronics.
- 12 September 2024
- Published by Universidade Federal do Parana in Revista de Engenharia Térmica
- Vol. 23 (2) , 03
THERMAL PERFORMANCE OF MINI FLAT PLATE HEAT PIPES FOR HIGH-POWER CHIPS
The waste heat generated by the high-power chips increases their operating temperature, reducing their performance and service life. Flat plate two-phase devices are promising cooling solutions for power electronics. Among them, the thermosyphons and pulsating heat pipes, which respectively promote the fluid circulation by gravity and oscillatory motion of liquid slugs and vapor plugs, are interesting devices to be investigated, as both show excellent heat transfer capacities. In the present work, the thermal performance of a mini flat plate thermosyphon is experimentally investigated and compared with that of a pulsating heat pipe, aiming for the thermal management of waste heat produced by miniaturized high-power chips. Both two-phase devices have the same external dimensions (100 x 55 mm2) and were manufactured by diffusion bonding technology. Distilled water was used as the working fluid. Tested in the same conditions, both operated successfully for the gravity-assisted mode; however, the thermosyphon, the lighter device, was able to transfer more heat. In the horizontal position, the pulsating heat pipe showed excellent thermal performance after the startup, working until high heat loads. In general, it was observed that the PHP became independent of gravity action for heat loads above 100 W.
- 12 September 2024
- Published by Universidade Federal do Parana in Revista de Engenharia Térmica
- Vol. 23 (2) , 03
THERMAL PERFORMANCE OF MINI FLAT PLATE HEAT PIPES FOR HIGH-POWER CHIPS
The waste heat generated by the high-power chips increases their operating temperature, reducing their performance and service life. Flat plate two-phase devices are promising cooling solutions for power electronics. Among them, the thermosyphons and pulsating heat pipes, which respectively promote the fluid circulation by gravity and oscillatory motion of liquid slugs and vapor plugs, are interesting devices to be investigated, as both show excellent heat transfer capacities. In the present work, the thermal performance of a mini flat plate thermosyphon is experimentally investigated and compared with that of a pulsating heat pipe, aiming for the thermal management of waste heat produced by miniaturized high-power chips. Both two-phase devices have the same external dimensions (100 x 55 mm2) and were manufactured by diffusion bonding technology. Distilled water was used as the working fluid. Tested in the same conditions, both operated successfully for the gravity-assisted mode; however, the thermosyphon, the lighter device, was able to transfer more heat. In the horizontal position, the pulsating heat pipe showed excellent thermal performance after the startup, working until high heat loads. In general, it was observed that the PHP became independent of gravity action for heat loads above 100 W.