JTJustina Tam

Justina Tam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Justina Tam has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lead Migration Following Sacral Neuromodulation Implantation: Contemporary Real‐World Experience From a High‐Volume Academic Center

    by Zhenyue Huang, Spencer H. Griffin, Sargam Panpaliya, Eshwin Varghese, Sara O'SUllivan‐Bakshi, Kathryn Bass, Heng Ruan, Tiffany Lynn Damm, Tal Cohen, Justina Tam, et al.

    Introduction: Lead migration is a recognized cause of recurrent symptoms and revision following sacral neuromodulation (SNM), yet its radiographic characteristics and associated risk factors remain poorly defined. We evaluated postoperative sacral imaging obtained for suspected lead migration to characterize migration patterns and to identify factors independently associated with lead migration in a contemporary cohort of patients undergoing SNM implantation. Materials and Methods: We performed a retrospective review of all patients undergoing SNM implantation at a tertiary academic referral center between September 2019 and June 2025. Lead migration was assessed by comparing baseline intraoperative fluoroscopic images with follow‐up radiographs using a standardized radiographic measurement protocol. Results: Among 445 patients undergoing SNM implantation, 173 met at least one predefined indication for postoperative imaging. Ninety‐two had both baseline and follow‐up imaging available for quantitative assessment. Overall, 35/445 (7.86%) patients had confirmed lead migration. Migration occurred predominantly in the forward direction (62.9%), with a median time to migration of 16 months (interquartile range, 7–28 months). A total of 29/35 patients (82.9%) underwent surgical revision or device removal. On Firth bias‐reduced multivariable logistic regression analysis, Axonics devices were associated with higher odds of lead migration compared with Medtronic devices (adjusted odds ratio [aOR], 2.66; 95% confidence interval [CI], 1.09–6.62; p = 0.031), after adjustment for implantation approach, rechargeable device status, BMI, and age‐adjusted CCI. Massive migration (> 21 mm) occurred only in Axonics devices. Conclusions: Lead migration following SNM implantation was uncommon but frequently resulted in surgical intervention. Axonics devices were associated with higher odds of lead migration after adjustment for selected clinical and device‐related factors. Importantly given the relatively small number of migration events and retrospective study design, this finding should be considered hypothesis‐generating rather than evidence of a causal association. Prospective multicenter studies are warranted to validate these findings and further define the mechanisms and clinical significance of SNM lead migration.

  • Brain Activity Changes During Bladder Filling in Women With Overactive Bladder After Percutaneous Tibial Neuromodulation

    by Justina Tam, Kenneth Wengler, Jie Yang, Chencan Zhu, Xiang He, Steven Weissbart

    Purpose: Percutaneous tibial neuromodulation (PTNM) is a standard third line therapy for patients with overactive bladder (OAB). While the therapy has demonstrated efficacy, its exact mechanism of action is unclear. Functional neuroimaging is employed to understand brain activity changes during the micturition cycle in women with OAB. In this study, we measure brain perfusion using functional MRI (fMRI) during bladder filling at discrete bladder volumes in women with OAB pre and post PTNM. We also assess brain perfusion at discrete bladder volumes in healthy women without OAB. Materials and Methods: Women with and without OAB were enrolled. All participants completed validated urinary symptom questionnaires. Subjects underwent an fMRI exam with arterial spin labeling (ASL) fMRI while their bladders were filled through a urethral catheter at discrete bladder volumes. Subjects with OAB underwent a second ASL fMRI after treatment with PTNM. Results: Twelve women with OAB and 13 women without OAB were enrolled. Patients with OAB had increased bladder filling sensations at lower bladder volumes compared to women without OAB. Anterior cingulate cortex (ACC), insula and supplemental motor area (SMA) perfusion during bladder filling did not increase in a linear fashion in healthy women nor women with OAB; there were changes in ACC, insula, and SMA perfusion during bladder filling at set bladder volumes, which changed after a single session of PTNM. Conclusions: Perfusion of the ACC, insula, or SMA does not change linearly during bladder filling in women, irrespective of OAB. After a single session of PTNM, perfusion changes during bladder filling in the ACC, Insula, and SMA in a non‐linear fashion.

  • Trends in Urogynecologic and Reconstructive Pelvic Surgery Among Early-career Urologists: Analysis of American Board of Urology Case Logs From 2009-2020

    by Zhenyue Huang, Tal Cohen, Kelly Ieong, Jason Zhang, Michael Ernst, Steven J. Weissbart, Justina Tam, Jason Kim


  • Open Access

    Abnormal Cerebral Perfusion and Functional Connectivity in Women with Overactive Bladder

    by Shichun Chen, Zongpai Zhang, Yakun Zhang, Kenneth Wengler, Steven Weissbart, Weiying Dai, Xiang He, Justina Tam

    Background: Overactive bladder (OAB) has been linked to abnormal cerebral blood flow (CBF) and functional connectivity (FC). However, findings related to CBF and FC changes in OAB remain inconsistent across the literature. Methods: This feasibility study employed arterial spin labeling (ASL) to investigate abnormal CBF and posterior cingulate cortex (PCC) FC in individuals with OAB, both at rest and during bladder filling. ASL images were collected from twenty-two female participants (twelve with OAB and ten healthy controls) at bladder filling volumes of 0, 50, 100, 200, 350, and 500 mL. For OAB participants, scans were obtained both at baseline and following a single-session treatment. ASL images were categorized into low-urge and high-urge conditions based on participants’ subjective urge rating during bladder filling. A flexible factorial design was implemented with three factors: subject, group (control, OAB at baseline, and OAB posttreatment), and urge state (low vs. high). Results: Compared to controls, OAB participants exhibited significant decreases in ΔCBF (high urge minus low urge) in the medial prefrontal cortex and increases in ΔCBF in the supramarginal region. Additionally, ΔPCC FC with the insula was reduced in OAB participants. Posttreatment, OAB participants showed increased ΔPCC FC with the postcentral and parietal (PocP), regions associated with the sensorimotor network. Notably, changes in ΔPCC-PocP FC were associated with improvements in OAB symptoms. Conclusions: These findings support the feasibility of using ASL to probe dysfunctional brain–bladder control mechanisms and treatment-related changes in OAB participants, highlighting the involvement of sensory processing and attention regulation in this condition.

  • Revision Rates for Rechargeable Versus Non‐Rechargeable Sacral Neuromodulation Devices in the Management of Overactive Bladder

    by Tal Cohen, Zhenyue Huang, Arshia Aalami‐Harandi, Jiyeon Park, Kaitlyn Sbrollini, Natalie Braun, Steven Weissbart, Justina Tam, Jason Kim

    Purpose: Overactive bladder (OAB) is a prevalent condition that can have a significant impact on quality of life. Sacral neuromodulation (SNM) is proven as an effective treatment option for OAB patients. Rechargeable devices have gained popularity in recent years. However, there is a paucity of data investigating revision rates for rechargeable SNM devices and associated impacting factors.Materials and Methods: We conducted a retrospective cohort study to investigate the revision rates of SNM devices in patients diagnosed with OAB. Patients who underwent implantation of rechargeable or non‐rechargeable SNM devices at our institution between January 2019 and June 2023 were included. Revision events, reasons for revisions, and patient demographics were analyzed and compared between the device groups.Results: The study included 246 patients. One hundred fifty received rechargeable SNM devices and 96 received non‐rechargeable devices. Revision rates were significantly different between the two groups, with 34% of patients in the rechargeable device group requiring revisions compared to 13.5% in the non‐rechargeable group (p < 0.001). The most common reasons for revision in the rechargeable group included difficulty charging (35.3%) and reduction of symptom improvement (23.5%). Having a rechargeable device resulted in a significantly higher probability of requiring a revision over time compared to non‐rechargeable (p < 0.001).Conclusion: Our study demonstrated that patients who received rechargeable SNM devices were more likely to require revision. Factors such as device malfunction or difficulties connecting to the device may contribute to the higher revision rates. Further studies are needed to elucidate factors affecting revision rates in SNM devices.


  • A Randomized Controlled Trial of Percutaneous Tibial Nerve Stimulation in the Treatment of Female Sexual Dysfunction

    by Zhenyue Huang, Sina Mehraban Far, Jonathan Aronov, Arshia Aalami Harandi, Kuemin Hwang, Xiaoyue Zhang, Varun Talanki, Heng Ruan, Tal Meir Cohen, Steven Weissbart, et al.

    Background: Female sexual dysfunction (FSD) is a prevalent and multifaceted condition affecting women's sexual well‐being. This randomized controlled trial aimed to evaluate the efficacy of percutaneous tibial nerve stimulation (PTNS) compared to a validated sham control in the treatment of FSD.Methods: We conducted a single‐center randomized controlled trial. Participants with FSD were recruited and randomly assigned at a 1:1 allocation ratio to either PTNS or a validated sham control using transcutaneous nerve stimulation (TENS). Treatment was performed through weekly 30‐min session for 12 weeks total. Sexual function was assessed at baseline, 6 weeks, and 12 weeks primarily using the Female Sexual Function Index (FSFI) questionnaire. Urogenital distress inventory‐6 was collected to evaluate for any baseline urinary incontinence/voiding dysfunction. Linear mixed‐effect models for longitudinal data were used to compare FSFI scores across different time points. Statistical analysis was performed using SAS 9.4 (SAS Institute Inc. Cary, NC).Results: In total, 34 PTNS and 31 TENS subjects were included in our final analysis. Overall, 48% (16/34) of PTNS subjects versus 29% (11/33) of TENS subjects were no longer at risk for FSD (FSFI > 26.55) after 12 weekly treatments. Both PTNS and TENS subjects demonstrated similar improvements in FSFI total scores after 12 weeks of treatments. Interestingly, patients who did not present with baseline urogenital distress symptoms reported a statistically significant larger improvement in sexual satisfaction after PTNS treatments as compared to placebo (p = 0.017).Conclusion: This study demonstrated a sustained efficacy of PTNS in improving sexual function. Specifically, patients who did not have coexisting urinary dysfunction reported significant improvement in sexual satisfaction after PTNS. Our study suggested that PTNS may have a direct neuromodulation effect on sexual dysfunction and may hold promise as a treatment modality for FSD.


  • Open Access

    Age- and Population-Adjusted Trends in Inpatient Surgical Management of Vaginal Prolapse, Rectal Prolapse, and Concurrent Vaginal and Rectal Prolapse Surgery

    by Justina Tam, Hannah G. Koenig, Celine R. Soriano, Alvaro Lucioni, Jennifer A. Kaplan, Kathleen C. Kobashi, Vlad V. Simianu, Una J. Lee

    ObjectiveTo report age- and population-adjusted trends in the prevalence of inpatient vaginal prolapse (VP), rectal prolapse (RP), and concurrent VP/RP surgical procedures in women in Washington State over a 12-year period.MethodsThe Comprehensive Hospital Abstract Reporting System, an inpatient claims database, was queried for female patients aged 20 years or older with a diagnosis of VP and/or RP and associated surgical procedures from 2008 to 2019. Rates for female patients were adjusted by age and population based on census results.ResultsBetween 2008 and 2019, inpatient admissions for concurrent VP/RP surgery remained stable, with adjusted rates ranging from 1.42 to 3.38 per 100 000, with a majority performed in patients < 80 years old. The population-adjusted rate of inpatient RP repairs remained stable at 3.12 to 5.14 per 100 000. The population-adjusted rate of inpatient VP repairs decreased dramatically, from 81.79 to 6.96 per 100 000.ConclusionsThe rate of inpatient RP and combined RP/VP surgical procedures was low and remained stable, while inpatient VP surgical repairs decreased substantially. Since the dataset is limited to inpatient surgery, this trend may reflect a shift to outpatient settings for VP surgeries. Nationally in the United States, there has been a trend toward multidisciplinary surgical management of concurrent VP/RP. However, this same trend does not appear to be reflected in Washington State, suggesting that nationwide trends may not be reflective of trends within each state. Further study is needed to understand how and why local trends in the management concurrent VP/RP may differ from national trends, and potentially improve concurrent VP/RP management using multidisciplinary approaches.