Ramazan Arslan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ramazan Arslan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Koray Gürsoy
Department of Plastic, Reconstructive and Aesthetic Surgery, Ankara Training and Research Hospital, Ankara, Turkey
2 shared publications - Murat Kara
Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Hacettepe University, Mehmet Akif Ersoy St., 06230, Ankara, Türkiye
2 shared publications - Uğur Koçer
Ankara Eğitim ve Araştırma Hastanesi
2 shared publications - Ayşegül Fırat
Department of Anatomy, Faculty of Medicine, Hacettepe University, Ankara, Turkey
1 shared publication - Burkay Akduman
S.B. Ankara Eğitim ve Araştırma Hastanesi
1 shared publication Ferhat Kargalıoğlu
Department of Plastic Reconstructive and Aesthetic Surgery, Ankara Research and Training Hospital, Ankara, Turkey
1 shared publication
Latest Publications
- Open Access
- 28 September 2023
- Published by Hacettepe University - Medical School in Acta Medica
- Vol. 54 (3) , 199-210
An effective technique in nerve defect repair: Analysis of sliding epineural tube graft technique and comparison with autologous nerve graft and turn-over epineural tube graft techniques
Objective: Autologous nerve graft (ANG) is the standard of care in the reconstruction of nerve gaps. However, scarification of a donor nerve, donor-site complications (wound complications, sensory dysfunction, neuroma, etc.) and unpredictable results lead surgeons to search for alternative techniques. Epineural tube graft (ETG) is a good option in the repair of nerve gaps. At this point, the present study aims to analyze the utility of the sliding epineural tube graft (SETG)technique in the reconstruction of nerve gaps. Materials and Methods: Thirty Wistar albino rats were divided into five groups according to the repair technique of a 7 mm nerve defect created on the right sciatic nerve. In Group 1 the defect was left unrepaired as a negative control group. The defect was repaired with ANG in Group 2, with turn-over ETG (TETG) in Group 3, with one-directional SETG (O-SETG) in Group 4 and with bi-directional SETG (B-SETG) in Group 5. On the 12th week of the experiment, electrophysiologic, gross macroscopic and microscopic evaluation of muscle function and microscopic assessments of muscle and nerve samples were performed. The left limb and proximal nerve segment of the defect area were used as the control side. Results: Electrophysiologic, macroscopic (wet muscle weight) and microscopic (axonal count, muscle fiber thickness was superior in the ANG group compared with TETG and SETG techniques. B-SETG showed poor results in all of the aforementioned findings. TETG and O-SETG techniques showed similar neuromuscular functions. Conclusion: Although the ANG technique has some disadvantages depending on the sacrification of a donor nerve and donor side, it has significantly superior reconstructive outcomes compared to ETG techniques. However, since the ETG techniques provide acceptable results, they should be in surgeons’ treatment repertoire because of the unique features of the microsurgical intervention.
- 28 September 2023
- Published by Hacettepe University - Medical School in Acta Medica
- Vol. 54 (3) , 199-210
Open AccessAn effective technique in nerve defect repair: Analysis of sliding epineural tube graft technique and comparison with autologous nerve graft and turn-over epineural tube graft techniques
Objective: Autologous nerve graft (ANG) is the standard of care in the reconstruction of nerve gaps. However, scarification of a donor nerve, donor-site complications (wound complications, sensory dysfunction, neuroma, etc.) and unpredictable results lead surgeons to search for alternative techniques. Epineural tube graft (ETG) is a good option in the repair of nerve gaps. At this point, the present study aims to analyze the utility of the sliding epineural tube graft (SETG)technique in the reconstruction of nerve gaps. Materials and Methods: Thirty Wistar albino rats were divided into five groups according to the repair technique of a 7 mm nerve defect created on the right sciatic nerve. In Group 1 the defect was left unrepaired as a negative control group. The defect was repaired with ANG in Group 2, with turn-over ETG (TETG) in Group 3, with one-directional SETG (O-SETG) in Group 4 and with bi-directional SETG (B-SETG) in Group 5. On the 12th week of the experiment, electrophysiologic, gross macroscopic and microscopic evaluation of muscle function and microscopic assessments of muscle and nerve samples were performed. The left limb and proximal nerve segment of the defect area were used as the control side. Results: Electrophysiologic, macroscopic (wet muscle weight) and microscopic (axonal count, muscle fiber thickness was superior in the ANG group compared with TETG and SETG techniques. B-SETG showed poor results in all of the aforementioned findings. TETG and O-SETG techniques showed similar neuromuscular functions. Conclusion: Although the ANG technique has some disadvantages depending on the sacrification of a donor nerve and donor side, it has significantly superior reconstructive outcomes compared to ETG techniques. However, since the ETG techniques provide acceptable results, they should be in surgeons’ treatment repertoire because of the unique features of the microsurgical intervention.
- 1 January 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75 (1) , 286-295
Analysis of 1430 hand fractures and identifying the ‘Red Flags’ for cases requiring surgery
- 1 January 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75 (1) , 286-295
Analysis of 1430 hand fractures and identifying the ‘Red Flags’ for cases requiring surgery