ISIlya G. Shatskiy

Ilya G. Shatskiy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ilya G. Shatskiy has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Alexandr Valerievich Vodovatov

    Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing; Saint Petersburg State Pediatric Medical University

    7 shared publications
  • Larisa A. Chipiga

    Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance of Consumer Rights Protection and Human Wellbeing

    6 shared publications
  • Polina S. Druzhinina

    Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance of Consumer Rights Protection and Human Wellbeing

    6 shared publications
  • Artem Mikhaylovich Biblin

    Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing

    3 shared publications
  • G. A. Gorsky

    Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing; I. Mechnikov North Western State Medical University

    3 shared publications
  • N. M. Vishnyakova

    Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights and Human Wellbeing; North-Western State Medical University named after I.I. Mechnikov

    3 shared publications

Latest Publications

  • Open Access

    Patient doses from radiographic procedures in St. Petersburg and the Leningrad Region

    by A. V. Vodovatov, E. A. Kosarlukova, P. S. Egorova, I. G. Shatsky, G. A. Gorsky, L. A. Eremina, N. M. Vishnyakova, D. A. Likhun, А. В. Водоватов, Е. А. Косарлукова, et al.

    Evaluation of patient doses for the establishment of diagnostic reference levels should be performed using dedicated dose surveys. Objective. To assess patient doses from common radiographic procedures in medical facilities in St-Petersburg and the Leningrad Region. Materials and Methods: Data on standard radiographic protocols were collected from 33 medical facilities in St-Petersburg and 18 medical facilities in the Leningrad Region, covering 137 digital X-ray units in St-Petersburg and 53 digital and 62 analogue X-ray units in the Leningrad Region in 2023-2025 and 2019-2021, respectively. Data were collected for radiography of the skull, chest, cervical, thoracic and lumbosacral spine, abdomen and pelvis in frontal and lateral projections. Effective dose, entrance surface dose and calculated dose-area product were determined for each protocol. Results and Discussion: For all radiographic procedures, differences between minimum and maximum patient doses were pronounced and reached up to two orders of magnitude. Statistically significant differences between regional patient-dose samples were observed only for individual procedures; no differences in effective dose were found between digital X-ray units in St-Petersburg and the Leningrad Region. When digital and analogue X-ray units in the Leningrad Region were compared, a significant difference was observed only for entrance surface dose in posteroanterior chest radiography. Standard patient doses in the present study differed significantly from the results of previous dose surveys, both upwards and downwards, indicating the need for detailed systematic assessment of patient doses. The data obtained may be used to justify numerical values of regional diagnostic reference levels. Conclusion: The study results showed that diagnostic reference levels should be established at the regional level, while pooling samples for digital and analogue X-ray units is acceptable.

  • Absorbed organ doses in computed tomography using personal radiation protective equipment: a phantom study of a five-year-old child

    by P. S. Druzhinina, I. G. Shatsky, L. A. Chipiga, S. Yu. Bazhin, E. N. Shleenkova, D. V. Alekseeva, O. I. Volok

    Despite international recommendations, some medical organizations continue the practice of using protective aprons, including for children. Existing calculation methods do not allow for the assessment of absorbed doses when using an apron, which makes direct dosimetric research relevant.    Materials and Methods:  The study was performed using a phantom of a 5-year-old child with thermoluminescent detectors. Chest scanning was conducted on a Somatom Force tomograph (Siemens, Germany, manufactured in 2022) with three apron use options: without an apron; with an apron wrapped around the phantom; and with an apron used as a blanket. Two scanning parameter sets were used: 1) fixed voltage of 70 kV with tube current modulation; 2) fully automatic mode.    Results and Discussion: Wrapping the apron resulted in both dose reduction in some radiosensitive organs and dose increase in others by a factor of 3–8. Using the apron as a blanket led to a substantial dose increase for the majority of radiosensitive organs and tissues, including organs fully or partially covered by the apron (3–15 times). In organs partially covered by the apron, dose changes depending on the PPE use case were most pronounced: in automatic scanning modes, when using the apron wrapped around the phantom, doses in these organs increased by a factor of 1.1–4.2 compared to doses in the same organs without protective apron; when using the apron as a blanket, doses in organs partially covered by the apron increased by a factor of 4.5–8.5.    Conclusion:  The use of an apron during computed tomography reduces doses in some organs but is accompanied by a significant (up to 15 times or more) increase in doses in others, especially in automatic modes.

  • Evaluation of the impact of personal protective equipment on the automatic exposure control system in computed tomography

    by I. G. Shatsky, P. S. Druzhinina, L. A. Chipiga, D. V. Alekseeva

    The relevance of this study lies in the need to reconsider established approaches to the use of personal protective equipment in computed tomography due to the widespread implementation of automatic tube current and voltage modulation algorithms. Since PPE can distort the input data for these algorithms, their use may not only fail to reduce but could also unjustifiably increase the patient's radiation dose, which requires detailed experimental verification, especially in pediatric practice where patients are most sensitive to ionizing radiation. The aim of this work is to assess the influence of personal protective equipment on the performance of the automatic tube current and voltage modulation programs (CareDose 4D and Care kV) during CT examinations on a Somatom Force (Siemens) scanner, using an anthropomorphic phantom of a five-year-old child. Materials and Methods : The study was conducted at the CT department of the Almazov National Medical Research Centre using an anthropomorphic phantom of a five-year-old child and a technically sound Somatom Force (Siemens) tomograph. To assess the impact of personal protective equipment on the operation of the automatic current and voltage modulation programs (CareDose 4D and Care kV), a series of phantom scans was performed with and without various positioning options for a protective lead apron, simulating real clinical practice. Results and Discussion : The results showed that when a lead apron enters the topogram area, the system interprets this as an increase in the patient's body size and density, which automatically increases the radiation parameters compared to a scan performed without the lead apron. Conclusion: Evaluating the impact of this effect on absorbed and effective doses requires further research to determine the appropriateness of using personal protective equipment in computed tomography.


  • Open Access

    Comments on amendments and additions to the mandatory requirements for radiation safety in X-ray diagnostics and therapy

    by A. V. Vodovatov, G. A. Gorsky, L. A. Chipiga, A. V. Likhacheva, I. G. Shatsky, P. S. Druzhinina, N. M. Vishnyakova

    Starting from September 1, 2025, SanPiN 2.6.4115-25 came into force. This is a comprehensive document that establishes requirements for ensuring radiation safety when working with a specific list of ionizing radiation sources, including those used in X-ray diagnostics and therapy. As a result, several regulatory legal acts in the field of radiation safety will be repealed, including SanPiN 2.6.1.1192-03 and SanPiN 2.6.1.2891-11. SanPiN 2.6.4115-25 introduces a number of new as well as revised and updated requirements for ensuring radiation safety in the operation of ionizing radiation-generating equipment used in medical practice. This paper presents analysis of the changes and additions introduced in SanPiN 2.6.4115-25 in comparison with the documents that should be repealed starting from September 1, 2025, which previously regulated radiation safety requirements for X-ray diagnostics and therapy. Conclusion: The work presents the background for revising the sanitary rules and standards and provides recommendations for improving the regulation of radiation protection in medical exposure.


  • Open Access

    Comments on amendments and additions to the mandatory requirements for radiation safety in radionuclide diagnostics and therapy

    by L. A. Chipiga, G. A. Gorsky, A. V. Vodovatov, A. V. Likhacheva, I. G. Shatsky, P. S. Druzhinina, N. M. Vishnyakova

    The regulatory legal acts of Rospotrebnadzor that established requirements for ensuring radiation safety during radionuclide diagnostics and therapy procedures before September 1, 2025 are significantly outdated and do not reflect the technologies and radionuclides currently in use. The development of nuclear medicine technologies and the introduction of an increasingly wide range of therapeutic radiopharmaceutical drugs necessitate the updating of requirements for the conduct of procedures, patient discharge, and waste management during radionuclide therapy, as well as the consideration of modern practices in organizing radionuclide therapy units based on radionuclide diagnostics departments. This work presents an analysis of the changes and additions introduced in SanPiN 2.6.4115-25, aimed at establishing unified requirements for ensuring radiation safety for personnel, the public, and patients during nuclear medicine procedures. The requirements implemented in SanPiN 2.6.4115-25 for ensuring radiation safety during nuclear medicine procedures have addressed two important scientific and practical problems: accounting for the specifics of modern nuclear medicine methods and resolving a number of contradictions among the existing regulatory legal acts of Rospotrebnadzor. Conclusion: SanPiN 2.6.4115-25 is fully harmonized with international regulatory documents and comprehensively includes requirements for ensuring radiation safety in radionuclide therapy, with an emphasis on protecting the public from radiation exposure.


  • Open Access

    Diagnostic reference levels for the city of Moscow during X-ray examinations

    by Yu. V. Druzhinina, Z. A. Lantukh, K. V. Tolkachev, I. V. Soldatov, M. P. Shatenok, A. V. Vodovatov, P. S. Druzhinina, I. G. Shatsky, S. A. Ryzhov

    Diagnostic reference levels are one of the effective tools for optimizing patient radiation doses in diagnostic radiology. The staff of domestic radiology departments does not have an understanding of the development process and use of diagnostic reference levels during X-ray examinations, although this tool is a generally accepted in practice abroad. The article shows the experience of forming regional diagnostic reference levels based on measurements provided by the accredited testing laboratory of the Scientific and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Healthcare Department. The diagnostic reference levels for radiography in Moscow were developed for eight of the most common types of examinations based on the operation of 216 digital X-ray machines. The resulting levels, expressed in the dose-area product (cGy-cm2) and effective dose (mSv), were compared with the local diagnostic reference levels for the Ryazan region, Russia, and national diagnostic reference levels for other countries. The analysis showed continuity in the values. Some types of studies have been optimized. The developed diagnostic reference levels are the quality performance indicators foe diagnostic radiology departments and will be used to optimize a patient radiation dose during diagnostic studies in Moscow.


  • Open Access

    Using disability-adjusted life years measure for characterization of radiation risk from fluoroscopy

    by L. V. Repin, R. R. Akhmatdinov, A. M. Biblin, A. V. Vodovatov, I. G. Shatskiy

    Medical diagnostics procedures involving the use of ionising radiation is one of the most intensively developing areas in medical diagnostics. At the same time, medical exposure of patients has a number of fundamental differences from other routine situations of planned exposure. As a rule, medical exposure is acute, and radiation doses in some types of examinations exceed the level of natural and man-made exposure associated with normal operation of radiation facilities. In such a situation, risk differentiation is of great importance, taking into account the different radiosensitivity of individual sex and age groups of patients. Radiation risks should be taken into account both when prescribing examinations involving the use of ionising radiation and when analysing the benefit-harm ratio associated with their application to specific patients. Another reason why risk assessment is an urgent task is the need to inform patients and/or their legal representatives about the health risks associated with the carrying out of examinations, including radiation risks. Within the framework of the present work, the risks associated with fluoroscopic examinations were assessed. To characterise the risk we used the DALY indicator, which is more and more frequently used in risk assessment, reflecting the possible number of lost years of healthy life as a result of radiation exposure during the study. The aim of the work was to calculate DALY values for different sex and age groups of patients from the Russian population during fluoroscopic examinations. To achieve this aim, the method of estimating the number of healthy life years lost due to exposure to ionising radiation, which was developed in the course of the research work, was used. The paper presents the results of calculating DALY values for three types of fluoroscopic examinations. This work represents the next step in the direction of harmonisation of radiation risk assessment methodology with the methodologies of risk assessment of other nature. One of the directions of using the calculation results is the development of methodological approaches to the calculation of sex- and age-dependent risk coefficients associated with medical exposure of patients. The analysis of the obtained results showed that the contribution of oncological diseases to the total radiation harm in older men was significantly higher than in women.


  • Open Access

    Characterization of radiation risk associated with computed tomography for the Russian patients using disability-adjusted life years measure

    by L. V. Repin, R. R. Akhmatdinov, A. M. Biblin, A. V. Vodovatov, L. A. Chipiga, I. G. Shatskiy

    Adiation risks assessment in medical exposure of patients is one of the mandatory steps in justifying the medical radiological examinations. The main objectives of such assessment are the need for benefit-harm analysis, when prescribing a study, and informing patients or their legal representatives about the radiation risk associated with the recommended examination. The traditional approach to radiation risk assessment is the use of measures based on lifetime morbidity and/or mortality due to radiation exposure in risk characterization. However, the development of the methodology of population health assessment and the need to harmonize the methodology of radiation risk assessment with risks from exposure to factors of other nature imply the use of more informative generalized health indicators in the assessment of exposure to harmful environmental factors. The aim of actual work was to apply the developed methodology of radiation detriment assessment to characterize the risk by calculating DALY (number of years of healthy full life lost due to exposure to ionizing radiation) values for different sex and age groups of Russian patients undergoing computed tomography. To achieve this goal, the previously developed method of estimating the number of years of healthy life lost due to exposure to ionizing radiation was used. Calculations were performed with the use of a specially developed computer program based on the models of the International Commission on Radiological Protection using medical and demographic data of Russian population. The article presents the results of DALY calculation for six types of computed tomographic examinations. The use of DALY to characterize risk instead of the most widely used value of radiation detriment (or lifetime risk of death, relating the harm from the reduction in the quality of life in the case of non-fatal oncological disease) is an attempt to harmonize the methodology of radiation risk assessment with the methodologies of other kind of health risks. One of the directions of calculation results usage is the development of sexand age-dependent risk coefficients associated with medical exposure of patients. The analysis of the obtained results showed that the age distribution of risks agrees well with the data presented in the methodological recommendations MR 2.6.1.0215-20 “Assessment of radiation risk to patients in radiology examinations”. It is also shown that the DALY indicator can serve as a basis for comparative assessment of obtainable and avoidable risks in the field of medical radiation exposure of patients.


  • Open Access

    Update of the federal governmental statistical surveillance form № 3-DOZ: “Data on patient doses from medical X-ray examinations”— Part 2 (FORM completion Recommendations)

    by Aleksandr V. Vodovatov, Larisa A. Chipiga, Polina S. Druzhinina, Ilya G. Shatskiy, Anastasiya V. Petryakova, Svetlana S. Sarycheva, Artem M. Biblin, Ruslan R. Akhmatdinov, Yuliya N. Kapyrina, Anzhelika A. Bratilova, et al.

    The form of federal governmental statistical surveillance № 3-DOZ, titled Data on patient doses from medical X-ray examinations, has changed significantly by the order of Rosstat N 880. In particular, the structure of the forms has been revised: studies involving high doses were dedicated from the rest; the section on radionuclide diagnostics has been redesigned; the information on the levels of patient exposure when using individual radionuclides and in hybrid studies have been displayed; information on the number of radiological studies and collective doses for pediatric patients have been introduced; and the number of studies for which typical (average) effective doses of patients are presented has been reduced. The structure of the updated form № 3-DOZ is presented within the framework of this work. In this article, recommendations for filling out № 3-DOZ have been developed in order to increase the reliability of the data provided and reduce the number of procedural errors. This work is a continuation of the article Vodovatov A.V., Chipiga L.A., Bratilova A.A., Druzhinina P.S., Shatskiy I.G., Petryakova A.V., Sarycheva S.S., Biblin A.M., Akhmatdinov R.R., Kapyrina Yu.N., Soldatov I.V., Puzyrev V.G., and Ryzhov S.A. Update of the federal governmental statistical surveillance form № 3-DOZ Data on patient doses from medical X-ray examinations. Perquisites for the update, published in the journal Radiatsionnaya Gygiena (2023. Vol. 16, N 2. P. 126136. DOI: https://doi.org/10.21514/1998-426X-2023-16-2-126-136).