Laura Maghiar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Laura Maghiar has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Mircea Sandor
Department of Surgical Disciplines, Faculty of Medicine and Pharmacy, University of Oradea, 1st December Square No. 10, 410073 Oradea, Romania
4 shared publications - Anca Huniadi
Department of Surgical Sciences, Obstetrics and Gynecology, Faculty of Medicine and Pharmacy, University of Oradea, 1 University Street, 410087 Oradea, Romania
3 shared publications - Liliana Sachelarie
Department of Dental Medicine, Apollonia University, 700511 Iasi, Romania
3 shared publications - Loredana Liliana Hurjui
Department of Morpho-Functional Sciences II, Physiology Discipline, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
2 shared publications - Adina Maria Marza
Department of Surgery, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania
1 shared publication - Alin Bodog
Faculty of Medicine and Pharmacy, University of Oradea, 1St December Square 10, 410073 Oradea, Romania
1 shared publication
Latest Publications
- Open Access
- 9 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5) , 500
Electrospun Nanofibers in Wound Healing: Real-World Evaluation of Spincare™ Technology
(1) Background: The increasing prevalence of chronic wounds, along with their significant healthcare burden, underscores the need for innovative and technologically advanced treatment strategies. Electrospun nanofiber-based dressings have emerged as a promising solution, mimicking the skin’s extracellular matrix and promoting efficient tissue regeneration. (2) Methods: This real-world, 10-month observational study conducted at CF Oradea Clinical Hospital enrolled 60 patients with chronic, non-healing wounds. Patients were randomly assigned to two groups: 30 received standard vacuum-assisted wound therapy, serving as the control group. In contrast, 30 received treatment with Spincare™, a novel electrospinning technology that delivers a personalized nanofiber matrix directly onto the wound. Symptom progression, pain levels, and treatment adaptation were assessed using standardized questionnaires. (3) Results: Patients treated with Spincare™ demonstrated faster wound healing, especially in the epithelialization phase, with significantly improved pain scores and quality of life measures. The technology was well-tolerated and reduced the need for repeated hospitalizations. (4) Conclusions: Spincare™ represents an effective and innovative electrospun nanofiber solution for chronic wound management, accelerating healing and enhancing patient outcomes, particularly in individuals with underlying conditions such as peripheral arterial disease. These findings support the integration of electrospinning-based therapies in modern wound care protocols.
- 9 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5) , 500
Open AccessElectrospun Nanofibers in Wound Healing: Real-World Evaluation of Spincare™ Technology
(1) Background: The increasing prevalence of chronic wounds, along with their significant healthcare burden, underscores the need for innovative and technologically advanced treatment strategies. Electrospun nanofiber-based dressings have emerged as a promising solution, mimicking the skin’s extracellular matrix and promoting efficient tissue regeneration. (2) Methods: This real-world, 10-month observational study conducted at CF Oradea Clinical Hospital enrolled 60 patients with chronic, non-healing wounds. Patients were randomly assigned to two groups: 30 received standard vacuum-assisted wound therapy, serving as the control group. In contrast, 30 received treatment with Spincare™, a novel electrospinning technology that delivers a personalized nanofiber matrix directly onto the wound. Symptom progression, pain levels, and treatment adaptation were assessed using standardized questionnaires. (3) Results: Patients treated with Spincare™ demonstrated faster wound healing, especially in the epithelialization phase, with significantly improved pain scores and quality of life measures. The technology was well-tolerated and reduced the need for repeated hospitalizations. (4) Conclusions: Spincare™ represents an effective and innovative electrospun nanofiber solution for chronic wound management, accelerating healing and enhancing patient outcomes, particularly in individuals with underlying conditions such as peripheral arterial disease. These findings support the integration of electrospinning-based therapies in modern wound care protocols.
- Open Access
- 9 October 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (10) , 1045
Correlation between Human Embryo Morphokinetics Observed through Time-Lapse Incubator and Life Birth Rate
(1) Background: Does the variation in sequential development times of embryos, observed through time-lapse monitoring, between the two study groups play a role in predicting pregnancy success? (2) Methods: The prospective double-arm study was to identify the morphokinetic parameters specific to embryos that were capable of implanting and were conducted on 89 embryos cultured in the Esco Miri time-lapse incubator, divided into two groups: Lot A, consisting of 57 embryos that successfully implanted and resulted in life birth rate (LBR), and Lot B (NLB), comprising 32 embryos that did not implant, leading to a negative beta-hCG outcome. (3) Results: Baseline characteristics, including female age, were not found to be statistically significant (p > 0.01). In contrast, there is a highly statistically significant difference concerning oocytes (p = 0.0029). Morphokinetic variables represented by sequential culture times were not statistically significant (p > 0.01) when comparing the two groups. However, the negative mean differences between these parameters suggest that the times for Lot A are better (shorter) than those for Lot B. While not statistically significant, these differences may still have practical significance. In the case of grading, the difference is considered to be extremely statistically significant (p < 0.01). (4) Conclusions: Although there are no statistically significant differences in sequential timings (p > 0.01) between the two groups, there are parameters indicating predictive potential for exploring pregnancy in embryo morphokinetics.
- 9 October 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (10) , 1045
Open AccessCorrelation between Human Embryo Morphokinetics Observed through Time-Lapse Incubator and Life Birth Rate
(1) Background: Does the variation in sequential development times of embryos, observed through time-lapse monitoring, between the two study groups play a role in predicting pregnancy success? (2) Methods: The prospective double-arm study was to identify the morphokinetic parameters specific to embryos that were capable of implanting and were conducted on 89 embryos cultured in the Esco Miri time-lapse incubator, divided into two groups: Lot A, consisting of 57 embryos that successfully implanted and resulted in life birth rate (LBR), and Lot B (NLB), comprising 32 embryos that did not implant, leading to a negative beta-hCG outcome. (3) Results: Baseline characteristics, including female age, were not found to be statistically significant (p > 0.01). In contrast, there is a highly statistically significant difference concerning oocytes (p = 0.0029). Morphokinetic variables represented by sequential culture times were not statistically significant (p > 0.01) when comparing the two groups. However, the negative mean differences between these parameters suggest that the times for Lot A are better (shorter) than those for Lot B. While not statistically significant, these differences may still have practical significance. In the case of grading, the difference is considered to be extremely statistically significant (p < 0.01). (4) Conclusions: Although there are no statistically significant differences in sequential timings (p > 0.01) between the two groups, there are parameters indicating predictive potential for exploring pregnancy in embryo morphokinetics.
- Open Access
- 11 January 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (1) , 85
Assessing the Efficacy of Laser Therapy and Autologous Platelet-Rich Plasma (PRP) Treatment for Chronic Wounds
(1) Background: The management of persistent wounds is a topic of significant concern, particularly when they become chronic. Clinicians are focused on reducing the healing duration of chronic wounds and employing the most efficient treatments. Successful wound management requires an understanding of standard healing processes, the elements that can impede healing progress, and strategies to manage these impediments. (2) Methods: We participated in a study involving a cohort of 115 patients. Data were collected through subjective assessments via questionnaires, examining the comparative effects of laser therapy and platelet-rich plasma (PRP) on patients’ conditions and monitored the progression of chronic wounds. For the study, we utilized a branded laser equipped with a 12-watt probe to stimulate chronic wounds in 65 patients, while the PRP procedure was administered to 50 patients. (3) Results: We observed a greater improvement in local symptoms among the patients who received laser therapy compared to those in the PRP group. (4) Conclusions: We consider both therapies to be of significant importance due to their positive and beneficial effects, particularly on the symptomatology and progression of chronic wounds. Nevertheless, superior results were documented in patients who underwent laser therapy.
- 11 January 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (1) , 85
Open AccessAssessing the Efficacy of Laser Therapy and Autologous Platelet-Rich Plasma (PRP) Treatment for Chronic Wounds
(1) Background: The management of persistent wounds is a topic of significant concern, particularly when they become chronic. Clinicians are focused on reducing the healing duration of chronic wounds and employing the most efficient treatments. Successful wound management requires an understanding of standard healing processes, the elements that can impede healing progress, and strategies to manage these impediments. (2) Methods: We participated in a study involving a cohort of 115 patients. Data were collected through subjective assessments via questionnaires, examining the comparative effects of laser therapy and platelet-rich plasma (PRP) on patients’ conditions and monitored the progression of chronic wounds. For the study, we utilized a branded laser equipped with a 12-watt probe to stimulate chronic wounds in 65 patients, while the PRP procedure was administered to 50 patients. (3) Results: We observed a greater improvement in local symptoms among the patients who received laser therapy compared to those in the PRP group. (4) Conclusions: We consider both therapies to be of significant importance due to their positive and beneficial effects, particularly on the symptomatology and progression of chronic wounds. Nevertheless, superior results were documented in patients who underwent laser therapy.
- Open Access
- 3 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6346
Perioperative Analgesia and Patients’ Satisfaction in Spinal Anesthesia for Cesarean Section: Fentanyl Versus Morphine
Perioperative analgesia for cesarean section aims to ensure the mother’s comfort, facilitate a smooth surgical experience, and promote a successful recovery. One-hundred-ninety patients were enrolled in a randomized double-blind study designed to assess the quality of perioperative analgesia, level of satisfaction, and incidence of adverse reactions in elective cesarean section under spinal anesthesia when fentanyl or morphine was added to bupivacaine. Two treatment groups comprising 173 subjects were compared in the per-protocol analysis: F (fentanyl, standard dose 25 μg) and M (morphine, standard dose 100 μg). Numerical pain scores were recorded perioperatively for 72 h (both at rest and on mobilization), with overall postoperative satisfaction and analgesic-related side effects. The patients in the morphine group had significantly better pain management (Mann–Whitney U test, p < 0.001) and higher level of satisfaction (Mann–Whitney U test, p < 0.001). The latter was related to the greater need for rescue medication in the fentanyl group (OR = 4.396; p = 0.019). On the other hand, fentanyl had significantly fewer non-life-threatening side effects, such as high-intensity pruritus (Mann–Whitney U test, p < 0.001), nausea (OR = 0.324; p = 0.019), vomiting and dizziness upon first mobilization (OR = 0.256; p < 0.001). It remains for future clinical trials to help establish doses that will tilt the scale to one side or the other.
- 3 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6346
Open AccessPerioperative Analgesia and Patients’ Satisfaction in Spinal Anesthesia for Cesarean Section: Fentanyl Versus Morphine
Perioperative analgesia for cesarean section aims to ensure the mother’s comfort, facilitate a smooth surgical experience, and promote a successful recovery. One-hundred-ninety patients were enrolled in a randomized double-blind study designed to assess the quality of perioperative analgesia, level of satisfaction, and incidence of adverse reactions in elective cesarean section under spinal anesthesia when fentanyl or morphine was added to bupivacaine. Two treatment groups comprising 173 subjects were compared in the per-protocol analysis: F (fentanyl, standard dose 25 μg) and M (morphine, standard dose 100 μg). Numerical pain scores were recorded perioperatively for 72 h (both at rest and on mobilization), with overall postoperative satisfaction and analgesic-related side effects. The patients in the morphine group had significantly better pain management (Mann–Whitney U test, p < 0.001) and higher level of satisfaction (Mann–Whitney U test, p < 0.001). The latter was related to the greater need for rescue medication in the fentanyl group (OR = 4.396; p = 0.019). On the other hand, fentanyl had significantly fewer non-life-threatening side effects, such as high-intensity pruritus (Mann–Whitney U test, p < 0.001), nausea (OR = 0.324; p = 0.019), vomiting and dizziness upon first mobilization (OR = 0.256; p < 0.001). It remains for future clinical trials to help establish doses that will tilt the scale to one side or the other.