Nyayu Aisyah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nyayu Aisyah has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Hifni Mukhtar Ariyadi
Universitas Gadjah Mada
3 shared publications Nugroho Adi Sasongko
National Research and Innovation Agency (BRIN)
3 shared publicationsAllan Trench
2 shared publicationsMartin Anda
2 shared publicationsYoyon Wahyono
National Research and Innovation Agency (BRIN)
2 shared publicationsDita Ariyanti
1 shared publication
Latest Publications
- 1 September 2026
- Published by International Centre for Applied Thermodynamics (ICAT) in International Journal of Thermodynamics
- Vol. 29 (3) , 230-240
Energy, Exergy, and Environmental Assessment of R-152a as a Low-GWP Alternative for R-134a in Domestic Heat Pump Water Heaters for Tropical Countries
Domestic heat pump water heaters offer an energy-efficient solution for hot water production in tropical countries. This study evaluates the energy and exergy performance as well as the environmental impact of R-152a as a replacement for R-134a in a domestic heat pump water heater. The evaluation uses a thermodynamic modelling approach under fixed operating conditions, with an evaporator temperature of 10°C, a condenser temperature of 50°C, and a water heating capacity of 1.6 m³. The results indicate that R-152a achieved an actual coefficient of performance (COP) of 6.25, which was 4.3% higher than that of R-134a at 5.99. R-152a also required a lower refrigerant mass flow rate. The mass flow rate decreased from 7.595 g/s for R-134a to 4.555 g/s for R-152a, which represents a reduction of approximately 40%. The exergy analysis further showed that R-152a consistently exhibited higher exergy efficiency than R-134a across the investigated ranges of evaporator temperature and compressor efficiency. This result indicates that R-152a has a lower thermodynamic irreversibility. From an environmental perspective, R-152a also showed a much lower direct Total Equivalent Warming Impact (TEWI). Its direct TEWI was 195.3 kg CO2-eq, which was 91.3% lower than that of R-134a at 2252.25 kg CO2-eq. This reduction is mainly related to the lower Global Warming Potential (GWP) of R-152a, which is 124, compared with 1430 for R-134a. The results demonstrate that R-152a is a promising low-GWP alternative to R-134a for domestic heat pump water heaters, offering improved thermodynamic performance, higher exergy efficiency, and substantially reduced environmental impact. However, its flammability must be carefully addressed through proper safety measures before practical implementation.
- 1 September 2026
- Published by International Centre for Applied Thermodynamics (ICAT) in International Journal of Thermodynamics
- Vol. 29 (3) , 230-240
Energy, Exergy, and Environmental Assessment of R-152a as a Low-GWP Alternative for R-134a in Domestic Heat Pump Water Heaters for Tropical Countries
Domestic heat pump water heaters offer an energy-efficient solution for hot water production in tropical countries. This study evaluates the energy and exergy performance as well as the environmental impact of R-152a as a replacement for R-134a in a domestic heat pump water heater. The evaluation uses a thermodynamic modelling approach under fixed operating conditions, with an evaporator temperature of 10°C, a condenser temperature of 50°C, and a water heating capacity of 1.6 m³. The results indicate that R-152a achieved an actual coefficient of performance (COP) of 6.25, which was 4.3% higher than that of R-134a at 5.99. R-152a also required a lower refrigerant mass flow rate. The mass flow rate decreased from 7.595 g/s for R-134a to 4.555 g/s for R-152a, which represents a reduction of approximately 40%. The exergy analysis further showed that R-152a consistently exhibited higher exergy efficiency than R-134a across the investigated ranges of evaporator temperature and compressor efficiency. This result indicates that R-152a has a lower thermodynamic irreversibility. From an environmental perspective, R-152a also showed a much lower direct Total Equivalent Warming Impact (TEWI). Its direct TEWI was 195.3 kg CO2-eq, which was 91.3% lower than that of R-134a at 2252.25 kg CO2-eq. This reduction is mainly related to the lower Global Warming Potential (GWP) of R-152a, which is 124, compared with 1430 for R-134a. The results demonstrate that R-152a is a promising low-GWP alternative to R-134a for domestic heat pump water heaters, offering improved thermodynamic performance, higher exergy efficiency, and substantially reduced environmental impact. However, its flammability must be carefully addressed through proper safety measures before practical implementation.
- 13 May 2025
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 11326-11350
Environmental and human health impact evaluation of nuclear power plant by using Life Cycle Assessment (LCA) in Indonesia
- 13 May 2025
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 11326-11350
Environmental and human health impact evaluation of nuclear power plant by using Life Cycle Assessment (LCA) in Indonesia
- Open Access
- 16 October 2024
- Published by Elsevier in Environmental and Sustainability Indicators
- Vol. 24
Estimating a national critical mineral security index in Indonesia using analytical hierarchy process
- 16 October 2024
- Published by Elsevier in Environmental and Sustainability Indicators
- Vol. 24
Open AccessEstimating a national critical mineral security index in Indonesia using analytical hierarchy process
- Open Access
- 15 January 2024
- Published by International Centre for Applied Thermodynamics (ICAT) in International Journal of Thermodynamics
- Vol. 27 (1) , 1-9
Performance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System
The search for environmentally friendly refrigerants for vapor compression systems has been a significant focus recently due to environmental concerns such as ozone depletion and global warming. In this study, the potential of R1224yd as an alternative refrigerant is investigated. A thermodynamic analysis of a 4-kW air conditioning system is conducted to assess the performance of R1224yd. The system is analyzed from a thermodynamic perspective, and key performance indicators such as the Coefficient of Performance and exergy efficiency. The results are then compared to R245fa and R123. Furthermore, a parametric study is performed to examine the impact of key parameters, such as evaporating and condensing temperatures, on the system's performance. This analysis provides insights into the sensitivity of the system's performance to variations in these parameters. The results indicate that R1224yd is a promising candidate as an environmentally friendly alternative refrigerant compared to R123 and R245fa. Because R1224yd has the lowest environmental impact. It has about 700 kg CO2 indirect emission, but about zero kgCO2 for direct emission. While, based on the thermodynamic results, R1224yd offers better performance compared to R245fa which has 1-3% higher in performance value and exergy efficiency, and has comparable performance to R123. This suggests that R1224yd can be a viable option for the systems, providing improved energy efficiency and lower environmental impact.
- 15 January 2024
- Published by International Centre for Applied Thermodynamics (ICAT) in International Journal of Thermodynamics
- Vol. 27 (1) , 1-9
Open AccessPerformance Evaluation of R1224yd as Alternative to R123 and R245fa for Vapor Compression Heat Pump System
The search for environmentally friendly refrigerants for vapor compression systems has been a significant focus recently due to environmental concerns such as ozone depletion and global warming. In this study, the potential of R1224yd as an alternative refrigerant is investigated. A thermodynamic analysis of a 4-kW air conditioning system is conducted to assess the performance of R1224yd. The system is analyzed from a thermodynamic perspective, and key performance indicators such as the Coefficient of Performance and exergy efficiency. The results are then compared to R245fa and R123. Furthermore, a parametric study is performed to examine the impact of key parameters, such as evaporating and condensing temperatures, on the system's performance. This analysis provides insights into the sensitivity of the system's performance to variations in these parameters. The results indicate that R1224yd is a promising candidate as an environmentally friendly alternative refrigerant compared to R123 and R245fa. Because R1224yd has the lowest environmental impact. It has about 700 kg CO2 indirect emission, but about zero kgCO2 for direct emission. While, based on the thermodynamic results, R1224yd offers better performance compared to R245fa which has 1-3% higher in performance value and exergy efficiency, and has comparable performance to R123. This suggests that R1224yd can be a viable option for the systems, providing improved energy efficiency and lower environmental impact.
- Open Access
- 1 January 2023
- Published by University Library in Kragujevac in Advanced Engineering Letters
- Vol. 2 (3) , 88-95
ENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
For a country with a tropical climate, such as Indonesia, heat pump technologies are usually necessary in high-altitude regions, where the temperatures tend to be cooler, such as a pool heater for an artificial hot spring swimming pool. A vapor compression heat pump’s optimal performance relies on its working fluid’s characteristics. This paper aimed to assess the performance and compare the time required to heat a hot spring pool using heat pumps with two different refrigerants: R32 and R134a. A thermodynamic modeling approach was employed to determine the better refrigerant choice between R32 and R134a for the heat pump, aside from other important factors that are considered when selecting the refrigerant, such as safety and environmental impacts. Comparing the results of R134a and R32 refrigerants, R134a has a higher GWP value than R32, indicating that R32 is more environmentally friendly. Regarding safety, R134a has low toxicity and flammability, while R32 exhibits low toxicity and mild flammability. Thus, R134a is considered safer than R32. Furthermore, the COP value of R134a was found to be higher than that of R32, indicating that R134a offers greater efficiency for the heat pump compared to R32.
- 1 January 2023
- Published by University Library in Kragujevac in Advanced Engineering Letters
- Vol. 2 (3) , 88-95
Open AccessENERGY PERFORMANCE ANALYSIS OF R32 AND R134A REFRIGERANT FOR SPRING POOL WATER HEATER
For a country with a tropical climate, such as Indonesia, heat pump technologies are usually necessary in high-altitude regions, where the temperatures tend to be cooler, such as a pool heater for an artificial hot spring swimming pool. A vapor compression heat pump’s optimal performance relies on its working fluid’s characteristics. This paper aimed to assess the performance and compare the time required to heat a hot spring pool using heat pumps with two different refrigerants: R32 and R134a. A thermodynamic modeling approach was employed to determine the better refrigerant choice between R32 and R134a for the heat pump, aside from other important factors that are considered when selecting the refrigerant, such as safety and environmental impacts. Comparing the results of R134a and R32 refrigerants, R134a has a higher GWP value than R32, indicating that R32 is more environmentally friendly. Regarding safety, R134a has low toxicity and flammability, while R32 exhibits low toxicity and mild flammability. Thus, R134a is considered safer than R32. Furthermore, the COP value of R134a was found to be higher than that of R32, indicating that R134a offers greater efficiency for the heat pump compared to R32.