Jian Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Guoqing Wu
School of Mechanical Engineering, Nantong Institute of Technology, Nantong 226002, China
3 shared publications - Wendong Zhang
Department of Mechanical Engineering, Nantong University, No. 9, Seyuan Road, Nantong 226001, China
3 shared publications - Yanan Yang
Department of Mechanical Engineering, Nantong University, No. 9, Seyuan Road, Nantong 226001, China
3 shared publications - Yang Cao
Department of Mechanical Engineering, Nantong University, No. 9, Seyuan Road, Nantong 226001, China
3 shared publications - Yixian Zhu
Department of Mechanical Engineering, Nantong University, No. 9, Seyuan Road, Nantong 226001, China
3 shared publications - Yujie Wang
Department of Mechanical Engineering, Nantong University, No. 9, Seyuan Road, Nantong 226001, China
3 shared publications
Latest Publications
- Open Access
Research on Aerodynamic Performance of Asynchronous-Hybrid Dual-Rotor Vertical-Axis Wind Turbines
This study analyzes the performance degradation of traditional hybrid wind turbines under high blade-tip-speed ratio conditions and proposes solutions through two-dimensional Computational Fluid Dynamics (CFD) simulations. It also introduces the design of two innovative asynchronous-hybrid dual-rotor wind turbines. The results indicate a remarkable 98.5% enhancement in torque performance at low blade-tip-speed ratios with the hybrid wind turbine model. However, as the blade-tip-speed ratio increases, it leads to negative torque generation within the inner rotor of the conventional design, resulting in a reduction of the power coefficient by up to 13.1%. The introduction of the new wind turbine design addresses this challenge by eliminating negative torque at high blade-tip-speed ratios through adjustments in the inner rotor’s operating range. This modification not only rectifies the negative torque issue but also enhances the performance of the outer rotor in the leeward region, consequently boosting the overall power coefficient. Moreover, the optimized inner rotor configuration effectively disrupts and shortens the wake length by 16.7%, with this effect intensifying as the rotational speed increases. This optimization is pivotal for enhancing the efficiency of multi-machine operations within wind farms.
Open AccessResearch on Aerodynamic Performance of Asynchronous-Hybrid Dual-Rotor Vertical-Axis Wind Turbines
This study analyzes the performance degradation of traditional hybrid wind turbines under high blade-tip-speed ratio conditions and proposes solutions through two-dimensional Computational Fluid Dynamics (CFD) simulations. It also introduces the design of two innovative asynchronous-hybrid dual-rotor wind turbines. The results indicate a remarkable 98.5% enhancement in torque performance at low blade-tip-speed ratios with the hybrid wind turbine model. However, as the blade-tip-speed ratio increases, it leads to negative torque generation within the inner rotor of the conventional design, resulting in a reduction of the power coefficient by up to 13.1%. The introduction of the new wind turbine design addresses this challenge by eliminating negative torque at high blade-tip-speed ratios through adjustments in the inner rotor’s operating range. This modification not only rectifies the negative torque issue but also enhances the performance of the outer rotor in the leeward region, consequently boosting the overall power coefficient. Moreover, the optimized inner rotor configuration effectively disrupts and shortens the wake length by 16.7%, with this effect intensifying as the rotational speed increases. This optimization is pivotal for enhancing the efficiency of multi-machine operations within wind farms.
- Open Access
A Study on the Effect of Turbulence Intensity on Dual Vertical-Axis Wind Turbine Aerodynamic Performance
Examining dual vertical-axis wind turbines (VAWTs) across various turbulence scenarios is crucial for advancing the efficiency of urban energy generation and promoting sustainable development. This study introduces a novel approach by employing two-dimensional numerical analysis through computational fluid dynamics (CFD) software to investigate the performance of VAWTs under varying turbulence intensity conditions, a topic that has been relatively unexplored in existing research. The analysis focuses on the self-starting capabilities and the effective utilization of wind energy, which are key factors in urban wind turbine deployment. The results reveal that while the impact of increased turbulence intensity on the self-starting performance of VAWTs is modest, there is a significant improvement in wind energy utilization within a specific turbulence range, leading to an average power increase of 1.41%. This phenomenon is attributed to the more complex flow field induced by heightened turbulence intensity, which delays the onset of dynamic stall through non-uniform aerodynamic excitation of the blade boundary layer. Additionally, the inherent interaction among VAWTs contributes to enhanced turbine output power. However, this study also highlights the trade-off between increased power and the potential for significant fatigue issues in the turbine rotor. These findings provide new insights into the optimal deployment of VAWTs in urban environments, offering practical recommendations for maximizing energy efficiency while mitigating fatigue-related risks.
Open AccessA Study on the Effect of Turbulence Intensity on Dual Vertical-Axis Wind Turbine Aerodynamic Performance
Examining dual vertical-axis wind turbines (VAWTs) across various turbulence scenarios is crucial for advancing the efficiency of urban energy generation and promoting sustainable development. This study introduces a novel approach by employing two-dimensional numerical analysis through computational fluid dynamics (CFD) software to investigate the performance of VAWTs under varying turbulence intensity conditions, a topic that has been relatively unexplored in existing research. The analysis focuses on the self-starting capabilities and the effective utilization of wind energy, which are key factors in urban wind turbine deployment. The results reveal that while the impact of increased turbulence intensity on the self-starting performance of VAWTs is modest, there is a significant improvement in wind energy utilization within a specific turbulence range, leading to an average power increase of 1.41%. This phenomenon is attributed to the more complex flow field induced by heightened turbulence intensity, which delays the onset of dynamic stall through non-uniform aerodynamic excitation of the blade boundary layer. Additionally, the inherent interaction among VAWTs contributes to enhanced turbine output power. However, this study also highlights the trade-off between increased power and the potential for significant fatigue issues in the turbine rotor. These findings provide new insights into the optimal deployment of VAWTs in urban environments, offering practical recommendations for maximizing energy efficiency while mitigating fatigue-related risks.
- Open Access
- 4 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10959
Optimization Layout and Aerodynamic Performance Research on Double Nautilus Vertical-Axis Wind Turbine
The double vertical-axis wind turbine (VAWT) system serves as a high-performance design solution. The Nautilus wind turbine investigated in this research imitated the structure of a Nautilus shell and is a vertical-axis drag-type wind turbine that exhibits relatively low efficiency. Therefore, the improvement of its wind energy efficiency is of paramount importance. This paper utilizes Computational Fluid Dynamics (CFD) software, based on the Reynolds-averaged Navier–Stokes equations and dynamic meshing techniques, to conduct numerical investigations on the aerodynamic performance of the Nautilus wind turbine array layout. The effects of wind direction, spacing ratio, and rotation direction are individually studied, and the interpretations and explanations are provided based on flow field characteristics. The results show that when the wind direction is 90°, i.e., a transverse layout, the closer the spacing between the transverse turbines, the higher the average power coefficient of the entire wind turbine system, with little effect from the three rotation directions. The maximum average power coefficient reached 28.9% and the power gain factor (TPGF) reached 11.1%. The enhancement effect primarily originates from the wake interaction among neighboring turbines. The experimental results showed a deviation of 8.1% compared to the CFD simulation results, thus validating the accuracy of the numerical CFD modeling. Ultimately, several array layouts are proposed, based on the prevalent wind direction and spacing ratio research. The enhancement of the wind turbine array’s situation could significantly increase the average efficiency of the entire wind turbine cluster. Consequently, this study provides a reference for the practical application of biomimetic vertical-axis drag-type wind turbine systems in actual engineering.
- 4 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10959
Open AccessOptimization Layout and Aerodynamic Performance Research on Double Nautilus Vertical-Axis Wind Turbine
The double vertical-axis wind turbine (VAWT) system serves as a high-performance design solution. The Nautilus wind turbine investigated in this research imitated the structure of a Nautilus shell and is a vertical-axis drag-type wind turbine that exhibits relatively low efficiency. Therefore, the improvement of its wind energy efficiency is of paramount importance. This paper utilizes Computational Fluid Dynamics (CFD) software, based on the Reynolds-averaged Navier–Stokes equations and dynamic meshing techniques, to conduct numerical investigations on the aerodynamic performance of the Nautilus wind turbine array layout. The effects of wind direction, spacing ratio, and rotation direction are individually studied, and the interpretations and explanations are provided based on flow field characteristics. The results show that when the wind direction is 90°, i.e., a transverse layout, the closer the spacing between the transverse turbines, the higher the average power coefficient of the entire wind turbine system, with little effect from the three rotation directions. The maximum average power coefficient reached 28.9% and the power gain factor (TPGF) reached 11.1%. The enhancement effect primarily originates from the wake interaction among neighboring turbines. The experimental results showed a deviation of 8.1% compared to the CFD simulation results, thus validating the accuracy of the numerical CFD modeling. Ultimately, several array layouts are proposed, based on the prevalent wind direction and spacing ratio research. The enhancement of the wind turbine array’s situation could significantly increase the average efficiency of the entire wind turbine cluster. Consequently, this study provides a reference for the practical application of biomimetic vertical-axis drag-type wind turbine systems in actual engineering.